STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 40,201–40,300 of 47,868
Assessing exercise intensity in cardiac rehabilitation: the use of a Polar heart rate monitor
Bethell, H. J. N., Letford, S., Evans, J., Turner, S. C., Maskell, J., & Culliford, D. J. (2008) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2008.3.11.31875 · Cited by 2
Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening
Choi, H. S., Choi, C. W., Park, M. J., Kang, H. M., & Yoo, J. H. (2007) · Tuberculosis & respiratory diseases · doi:10.4046/trd.2007.62.4.276 · Cited by 2
Derivation of Whole Body Bone Measures Through Summation of Individual DXA Scans
Misic, M. M., & Evans, E. M. (2006) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2005.10.002 · Cited by 2
Human semen can be air-dried prior to testing for sperm DNA fragmentation with the Halosperm® G2 kit
Yap, K., & MATSON, P. L. (2012) · Asian Pacific Journal of Reproduction · doi:10.1016/s2305-0500(13)60058-5 · Cited by 2
Developing a bio-mechanotronic probing system for estimating soft tissue Young’s modulus in vivo
Alja'afreh, T. (2011) · Instruments and Experimental Techniques · doi:10.1134/s0020441211010027 · Cited by 2
Armitage, P. A., Rivers, C. S., Karaszewski, B., Thomas, R. G. R., Lymer, G. K. S., Morris, Z., & Wardlaw, J. M. (2011) · European Radiology · doi:10.1007/s00330-011-2284-2 · Cited by 2
Tafti, M. R. F., Moghadam, R. S., Beheshtnejad, A. H., Jabbarvand, M., Mohebbi, M., & Zarei-Ghanavati, M. (2013) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2013.05.043 · Cited by 2
Bleul, U., & Götz, E. (2014) · Comparative Clinical Pathology · doi:10.1007/s00580-013-1869-3 · Cited by 2
Kanahara, M., Harada, H., Niiyama, H., Katoh, A., Kai, H., & Ikeda, H. (2011) · Thrombosis Research · doi:10.1016/j.thromres.2011.08.026 · Cited by 2
Phase analysis detects heterogeneity of myocardial deformation on cine MRI
Maret, E., Liehl, M., Brudin, L. H., Tödt, T., Edvardsen, T., & Engvall, J. E. (2015) · Scandinavian Cardiovascular Journal · doi:10.3109/14017431.2015.1023343 · Cited by 2
Block, F. E., Fletcher, M. V., Morris, T. J., & Dzwonczyk, R. R. (1991) · The Journal of Clinical Monitoring · doi:10.1007/bf01619267 · Cited by 2
Analytical performance of a monoclonal digoxin assay by dry chemistry on the Vitros 950
Frezzotti, A., Giordano, G., & Gambini, A. M. M. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185454 · Cited by 2
Bassaneze, V., Sacramento, C. B., Freire, R., Alencar, P. F. D., Ortega, N. R. S., & Krieger, J. E. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070605 · Cited by 2
Lai, K. N., Szeto, C., Ho, K. K. L., Yu, A. W. Y., Mak, T. W. C., & Lam, C. W. K. (1998) · American Journal of Nephrology · doi:10.1159/000013356 · Cited by 2
MRI Evaluation of a Stented Abdominal Aorta of a Rabbit
Shin, M., Brott, B. C., Lloyd, S. G., Evanochko, W. T., Kiss, P., Baker, R. A., & Anayiotos, A. S. (2007) · ASME Summer Bioengineering Conference (SBC) · doi:10.1115/sbc2007-176395 · Cited by 2
Design and Validation of an Infrared Badal Optometer for Laser Speckle
Teel, D. F. W., Copland, R. J., Jacobs, R. J., Wells, T., Neal, D. R., & Thibos, L. N. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181852742 · Cited by 2
Wasserfallen, J., & Leuenberger, P. (1996) · Journal of Asthma · doi:10.3109/02770909609054549 · Cited by 2
A comparison of brachial artery reactivity measured by external and intravascular ultrasound
Ong, P. J. L., Webb, C. M., Sørensen, M. B., Hayward, C., & Collins, P. D. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00542-2 · Cited by 2
Transmission Pulse Oximetry in the Fetal Lamb: Is There a Universal Calibration?
Nijland, R., Jongsma, H. W., Crevels, J., Menssen, J., Nijhuis, J. G., & Oeseburg, B. (1996) · Pediatric Research · doi:10.1203/00006450-199603000-00014 · Cited by 2
A Comparison of Two Anaerobic Test Measurement Systems using an Upper Body Wingate Test
Talbot, C., Kay, T. D., Walker, N., & Price, M. (2014) · Research in Sports Medicine · doi:10.1080/15438627.2014.915836 · Cited by 2
Eder, V., Herault, S., Hudelo, C., Giraudeau, B., Marchal, C., Quilliet, L., Pottier, J.-M., & Arbeille, P. L. (2000) · European Journal of Ultrasound · doi:10.1016/s0929-8266(00)00077-x · Cited by 2
Saremi, F., Bai, C., Saremi, A., Young, C., Garon, B. L., Lee, C., Hassani, C., & Ihde, L. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.07.176 · Cited by 2
Precision and Accuracy of Proview Tonometer: Clinical Implications for Self-Tonometry
Choudhari, N. S., Sekhar, G. C., Nutheti, R., & Thomas, R. (2005) · Journal of Glaucoma · doi:10.1097/01.ijg.0000188875.69893.72 · Cited by 2
Ambulatory heart rate is underestimated when measured by an ambulatory blood pressure device
Vrijkotte, T. G. M., & de Geus, E. J. C. (2001) · Journal of Hypertension · doi:10.1097/00004872-200107000-00016 · Cited by 2
Analysis of Bias and ART Enrollment for a Point-of-Care CD4/CD4% Analyzer
Mangwanya, M. C. D. (2013) · Journal of AIDS & Clinical Research · doi:10.4172/2155-6113.1000247 · Cited by 2
Drechsler, H., Masztalewicz, M., Safranow, K., & Nowacki, P. (2013) · Neurologia i Neurochirurgia Polska · doi:10.5114/ninp.2013.35573 · Cited by 2
Jiménez-Román, J., Gil‐Carrasco, F., Martinez, A., Albis-Donado, O., & de la Torre-Tovar, J. D. (2012) · International Ophthalmology · doi:10.1007/s10792-012-9674-6 · Cited by 2
Drosch, T., Tsiflikas, I., Brodoefel, H., Heuschmid, M., Reimann, A., Thomas, C. K., Ketelsen, D., Wurster, D., Schroeder, S., & Burgstahler, C. (2010) · Heart and Vessels · doi:10.1007/s00380-009-1157-y · Cited by 2
A comparison of digital morphometry and clinical measurements of ears
Öberg, M., Svensson, H., Björk, C., Flodin, J., & Wikström, S. (2013) · Journal of Plastic Surgery and Hand Surgery · doi:10.3109/2000656x.2013.766886 · Cited by 2
Wilson, S., Bowyer, A., & Harrap, S. B. (2015) · Medical Devices Evidence and Research · doi:10.2147/mder.s76409 · Cited by 3
A modified sensor for pulse oximetry in children
Howell, S. J., Blogg, C. E., & ASHBY, M. W. (1993) · Anaesthesia · doi:10.1111/j.1365-2044.1993.tb07534.x · Cited by 2
Kawano, Y., Ohmori, K., Wada, Y., Kondô, I., Mizushige, K., Senda, S., Nozaki, S., & Kohno, M. (2000) · Heart and Vessels · doi:10.1007/s003800070009 · Cited by 2
Reproducibility of a simplified Q-angle measurement technique
Peeler, J. D., Leiter, J., & Anderson, J. E. (2010) · Current Orthopaedic Practice · doi:10.1097/bco.0b013e3181b9cf76 · Cited by 3
Main bronchial diameters in patients with very severe COPD
Mourissoux, G., Vandendries, C., Neveu, H., Scherrer, A., & Fischler, M. (2010) · Journal of Anesthesia · doi:10.1007/s00540-010-0924-3 · Cited by 2
Volume measurement of a pediatric ventricular phantom model using three-dimensional echocardiography
Iino, M., Shiraishi, H., Ichihashi, K., Hoshina, M., & Momoi, M. Y. (2006) · Journal of Medical Ultrasonics · doi:10.1007/s10396-006-0096-9 · Cited by 2
Effect of Slice Thickness Reconstruction on Quantitative Vascular Parameters in Perfusion CT
de Alegría, A. M., García‐Figueiras, R., Baleato‐González, S., Rodríguez‐Álvarez, M. X., Martínez-Souto, I., & Villalba‐Martín, C. (2014) · Open Journal of Radiology · doi:10.4236/ojrad.2014.41007 · Cited by 2
Bennani, V., & Shahmiri, R. (2008) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)60295-4 · Cited by 2
Evaluation of the Alcon Renaissance handheld automated keratometer
Hammack, G. G. (1997) · International Contact Lens Clinic · doi:10.1016/s0892-8967(97)00007-2 · Cited by 2
Mathematical Analysis of Urea Rebound in Long‐term Hemodialysis Patients
Ookawara, S., Suzuki, M., Saitou, M., & Tabei, K. (2005) · Therapeutic Apheresis and Dialysis · doi:10.1111/j.1774-9987.2005.00231.x · Cited by 2
An observational study of a wireless temporal artery bandage thermometer
Stelfox, H. T., Straus, S. E., Khandwala, F., Conly, J. M., Haslett, J., & Zwierzchowski, S. (2010) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-010-9343-z · Cited by 2
Yip, K., Goh, V., Gregory, J., Simcock, I. C., Stirling, J., Taylor, N. J., Kozarski, R., Mitchell, A., Bosopem, S., Halbert, G., et al. (2014) · Journal of Cancer Therapy · doi:10.4236/jct.2014.51006 · Cited by 2
Sachithanandham, J., Solomon, K., Prasannakumar, S., Nithyandham, G., & Kannangai, R. (2011) · Indian Journal of Medical Microbiology · doi:10.4103/0255-0857.90176 · Cited by 2
Puga, G. M., Nakamura, F. Y., Simões, H. G., Kokubun, E., & Campbell, C. S. G. (2009) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922009000300009 · Cited by 2
Huang, C.-C., Kao, K., Fu, J., & Hsieh, M. (2010) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2010.07.005 · Cited by 2
Arraiza, M., Azcárate, P., Arias, J., Cecco, C. N. D., Pueyo, J. C., Rábago, G., & Bastarrika, G. (2012) · Radiología (English Edition) · doi:10.1016/j.rxeng.2011.05.002 · Cited by 2
Comparison of expert and algorithm agreement in measurement of nerve conduction study parameters
Tracey, B., Iyer, D., Lesser, E. A., Potts, F., & Gozani, S. N. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2010.02.001 · Cited by 2
Oxygen flow through nasal cannulae
Henderson, C. L., Rosen, H. D., & Arney, K. L. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03011779 · Cited by 2
A multi-rater nonparametric test of agreement and corresponding agreement plot
Hutson, A. D. (2009) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2009.07.019 · Cited by 2
Dale, A. M., Agboola, F., Yun, A. J., Zeringue, A., Al-Lozi, M., & Evanoff, B. (2014) · PM&R · doi:10.1016/j.pmrj.2014.10.003 · Cited by 2
Accuracy of the oscillometric method to measure blood pressure in children
Filho, E. A. R., Mello, S. F. R., Silva, C., Vituri, D. W., Bazoni, E., & Gordan, L. N. (1999) · Jornal de Pediatria · doi:10.2223/jped.264 · Cited by 2
Reininga, I. H. F., LEMMINK, K. A. P. M., Diercks, R. L., Buizer, A. T., & Stevens, M. J. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-84 · Cited by 3
Finite Element Modeling of Inverted (Inside Out) Soft Contact Lenses
Conrad, F., Ehrmann, K., Choo, J. D., & Holden, B. A. (2010) · Journal of Medical Devices · doi:10.1115/1.4001519 · Cited by 2
Willoteaux, S., Moranne, O. P., Duda, S. H., Lions, C., Gaxotte, V., Durand, F., Negawi, Z., & Bérégi, J.-P. (2006) · Journal of Endovascular Therapy · doi:10.1583/05-1616.1 · Cited by 2
Kang, D.-W., Seo, Y., Oh, N.-S., & Lim, H. (2012) · The Journal of Korean Academy of Prosthodontics · doi:10.4047/jkap.2012.50.4.258 · Cited by 2
Mousty, E., Huberlant, S., Pouget, O., Marès, P., de Tayrac, R., & Letouzey, V. (2013) · The French Journal of Urology · doi:10.1016/j.purol.2013.03.018 · Cited by 2
Raninen, R. O. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00048-9 · Cited by 2
Wylde, V., Livesey, C., Learmonth, I. D., Blom, A. W., & HEWLETT, S. E. (2010) · Musculoskeletal Care · doi:10.1002/msc.170 · Cited by 3
Common Peroneal Nerve Stimulation for Neuromuscular Monitoring
Leslie, K., Iatrou, C. C., Jones, K., & Beemer, G. H. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199901000-00037 · Cited by 2
Kistorp, C., Toubro, S., Astrup, A. V., & Svendsen, O. L. (1999) · Clinical Physiology · doi:10.1046/j.1365-2281.1999.00185.x · Cited by 2
Accuracy Evaluation of Two Systems for Self-Monitoring of Blood Glucose Following ISO 15197
Wang, Y. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814547385 · Cited by 2
Kropmans, T., & Jerković‐Ćosić, K. (2004) · European Journal Of Dental Education · doi:10.1111/j.1600-0579.2004.00342.x · Cited by 2
Inspecting associations in multivariate data sets with an interactive modified Bland-Altman plot.
Kozak, M., & Wnuk, A. (2011) · Romanian Agricultural Research · Cited by 2
Altunkeser, B. B., Özdemir, K., Özdil, H., Gök, H., & Aydın, M. (2002) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2002.tb00168.x · Cited by 2
Stigö, A., Johansen, P., Jensen, M. Ø., Sivesgaard, K., Nygaard, H., & Sloth, E. (2010) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-8-40 · Cited by 2
Papasouliotis, K., Tennant, K., Dodkin, S. J., & Mason, J. C. (2012) · ISRN Veterinary Science · doi:10.5402/2012/475419 · Cited by 2
Training programme impact on thermoplastic immobilization for head and neck radiation therapy
Outhwaite, J., McDowall, W. R., Marquart, L., Rattray, G., Fielding, A. L., & Hargrave, C. (2012) · Radiography · doi:10.1016/j.radi.2012.09.003 · Cited by 2
Ayabe, M., Brubaker, P. H., Sunami, Y., Kumahara, H., Schütz, Y., & Tanaka, H. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2013.803589 · Cited by 4
Liotto, N., Radaelli, T., Orsi, A., Taricco, E., Roggero, P., Giannì, M. L., Consonni, D., Mosca, F., & Cetin, I. (2010) · The Italian Journal of Pediatrics/Italian journal of pediatrics · doi:10.1186/1824-7288-36-70 · Cited by 2
Arai, K., Funayama, R., Takahashi, M., Bizmark, R. S., Shimizu, H., Obayashi, N., & Matsui, A. (2014) · Pediatrics International · doi:10.1111/ped.12504 · Cited by 2
Ohuchi, H., Hayashi, T., Yamada, O., & Echigo, S. (2005) · CHEST Journal · doi:10.1378/chest.128.5.3576 · Cited by 2
O’Hara, B., Greenwood, D. C., Burley, V. J., & Cade, J. E. (2004) · Journal of Human Nutrition and Dietetics · doi:10.1111/j.1365-277x.2004.00553.x · Cited by 2
Koyalta, D., Jenabian, M.-A., Nadjiouroum, N., Djouater, B., Djemadji‐Oudjeil, N., Ndjoyi‐Mbiguino, A., & Bélec, L. (2013) · BMC Research Notes · doi:10.1186/1756-0500-6-169 · Cited by 2
Intrahospital Correlation of the International Normalized Ratio
Lazo‐Langner, A., Villa-Márquez, R., Hernández‐Hernández, D., Rojas-Maya, S., & Piedras, J. (2008) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/1076029608315167 · Cited by 2
Bayarri, M. S., Tahoces, P. G., Capdevila, L. R. M., Suárez-Cuenca, J. J., Monzonís, A. M., & Carreira, J. (2011) · Radiología · doi:10.1016/j.rx.2010.07.008 · Cited by 2
Chronotropic response during exercise and recovery in men with mild systolic chronic heart failure.
Krakowiak, B., Banasiak, W., Ponikowski, P. P., & Jankowska, E. A. (2010) · PubMed · Cited by 3
Noulsri, E., Lerdwana, S., Sukapirom, K., Thepthai, C., Onlamoon, N., Tassaneetrithep, B., & Pattanapanyasat, K. (2011) · PubMed · Cited by 2
Rone-Adams, S. A., & Naylor, S. (2009) · Internet Journal of Allied Health Sciences and Practice · doi:10.46743/1540-580x/2009.1267 · Cited by 2
Validity of Fat-Free Weight Equations for Estimating Mean and Peak Power in High School Wrestlers
Zuñiga, J. M., Housh, T. J., Mielke, M. M., Camic, C. L., Hendrix, C. R., Johnson, G. O., Housh, D. J., & Schmidt, R. J. (2009) · Pediatric Exercise Science · doi:10.1123/pes.21.1.100 · Cited by 2
El-Minshawy, O., & Elbassuoni, E. (2012) · Iranian Journal of Kidney Diseases · Cited by 2
Measurement of End-Tidal Carbon Dioxide in Spontaneously Breathing Children After Cardiac Surgery
Rasera, C. C., Gewehr, P. M., Domingues, A. M. T., & Junior, F. F. (2011) · American Journal of Critical Care · doi:10.4037/ajcc2011537 · Cited by 2
Hole, A. Å. T. (2001) · Scandinavian Cardiovascular Journal · doi:10.1080/140174301750101465 · Cited by 2
A global quality control system to check PT ‐ INR portable monitor for Antivitamin K antagonists
Testa, S., Paoletti, O., Bassi, L., Dellanoce, C., Morandini, R., & Lippi, G. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12239 · Cited by 2
A Simple Assessment of Left Ventricular Function and Mass with Cine MRI
Sharma, R. K., Sharma, A. K., & Williams, C. D. H. (2010) · Cited by 2
Jackson, D. M., Donaghy, Z., Djafarian, K., & Reilly, J. J. (2014) · PubMed Central · Cited by 4
Měšťan, M., Babu, A., & Kvasnička, J. (2006) · EP Europace · doi:10.1093/europace/euj044 · Cited by 2
Sowunmi, A. (2011) · The Open Tropical Medicine Journal · doi:10.2174/1874315301104010033 · Cited by 2
Medical statistics in obstetrics and gynaecology
Bland, M. (1997) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(97)00204-2 · Cited by 3
Trivedi, S. J., Lim, T. W., Barry, M. A., Byth, K., Ross, D. L., Thiagalingam, A., & Kovoor, P. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9750-x · Cited by 2
Tweed, N., Williams, S., Williams, D., & Dingley, J. (2014) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2014.02.001 · Cited by 3
Jin, Z., Briedigkeit, W., Gamillscheg, A., Berger, F. F., Skinner, J. R., Golshahi, F., Uhlemann, F., & Lange, P. (1997) · Cardiology in the Young · doi:10.1017/s1047951100004194 · Cited by 2
Valentini, F. A., Robain, G., & Marti, B. G. (2012) · International braz j urol · doi:10.1590/1677-553820133806809 · Cited by 2
Azulay, D.-O. D., Murphy, P. S., & Jim Graham, A. (2013) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2013.09.001 · Cited by 2
Carpal tunnel syndrome diagnosis: validation of a clinic-based nerve conduction measurement device
Green, T. P., Kallio, M., Clarke, M., Pathak, P., Lesonen, V., & Tolonen, U. (2011) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2011.44038 · Cited by 2
Estimation of the VA/(Q+VTIS) distribution from single-breath alkane uptake
van den Aardweg, J. G., Kežić, S., Bosch, J. A., & Monster, A. C. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930902 · Cited by 2
Beresford, H., O'Donnell, M., & Soulsby, C. (2008) · Proceedings of The Nutrition Society · doi:10.1017/s0029665100591101 · Cited by 2
Test Your Memory-test: een mogelijk alternatief voor de MMSE1
Koekkoek, P. S., Rutten, G. E. H. M., van den Berg, E., Kappelle, J. L. J., & Biessels, G. J. (2013) · Neuropraxis · doi:10.1007/s12474-013-0023-y · Cited by 2
A comparison of the accuracy of ulnar versus median nerve stimulation for neuromuscular monitoring
Lee, H. J., Kim, K. S., Shim, J. C., & Yoon, S. W. (2011) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2011.60.5.334 · Cited by 2
Rat, A., Pouchot, J., Coste, J., Baumann, C., Spitz, E., Retel-Rude, N., Baumann, M., Quintrec, J.-S. G.-L., Dumont‐Fischer, D., & Guillemin, F. (2006) · Revue du Rhumatisme · doi:10.1016/j.rhum.2006.01.023 · Cited by 2
Waxman, J. P., Schmitz, R. J., & Shultz, S. J. (2015) · Journal of Applied Biomechanics · doi:10.1123/jab.2014-0289 · Cited by 2
Are conventional pressure‐flow measurements dependent upon filled volume?
Sahadevan, K., Leonard, A. S., & PICKARD, R. S. (2005) · British Journal of Urology · doi:10.1111/j.1464-410x.2005.05629.x · Cited by 2
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.