STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 40,101–40,200 of 47,868
Outcome-Parameter bei Psoriasisarthritis
Braun, J. M., & Wassenberg, S. (2006) · Zeitschrift für Rheumatologie · doi:10.1007/s00393-006-0046-3 · Cited by 2
Parker, S., Ciaccio, M., Cook, E., Davenport, G., Cooper, A., Grange, S., & Smitham, P. J. (2015) · Archives of Osteoporosis · doi:10.1007/s11657-015-0230-7 · Cited by 2
Pouteil‐Noble, C., Remontet, L., Lombardo, M., Touraine, J. L., Hadj‐Aïssa, A., & Pozet, N. (1997) · Springer eBooks · doi:10.1007/978-94-011-5434-5_4 · Cited by 2
Özkol, M. (2014) · Isokinetics and Exercise Science · doi:10.3233/ies-140536 · Cited by 2
Estimating Temporal Parameters of Wheelchair Propulsion based on Hand Acceleration
Koontz, A. M., Ding, D., & Hiremath, S. V. (2008) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2
Gallagher, M. M., Guo, X. H., Poloniecki, J., & Camm, A. J. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02755.x · Cited by 2
Álvarez, A. L., Álvarez, J. M. E., Flórez, D. D. P. Q., & Bedoya, D. M. (2010) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · doi:10.19052/sv.826 · Cited by 2
Anwar, A. M., Nosir, Y. F. M., Galal, A. N., AlBarakati, M., & Chamsi‐Pasha, H. (2012) · Echocardiography · doi:10.1111/j.1540-8175.2012.01711.x · Cited by 2
Assessment of Stereoscopic Precision - Film to Digital Photogrammetric Cameras
Arias-Prez, B., Gonzlez-Aguilera, D., Gómez‐Lahoz, J., & Hernndez-Lpez, D. (2012) · InTech eBooks · doi:10.5772/34563 · Cited by 2
A generic packaging technique using fluidic isolation for low-drift implantable pressure sensors
Kim, A., Powell, C. R., & Ziaie, B. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7180964 · Cited by 2
IKENONO, Y., MATUYAMA, Y., MIKAWA, K., & Yoshiyasu, Y. O. Z. A. (2014) · Rigakuryoho Kagaku · doi:10.1589/rika.29.491 · Cited by 2
Assessment of Growth in Adolescent Athletes
Hills, A. P., & Pařízková, J. (2002) · CRC Press eBooks · doi:10.1201/9781420041323.ch6 · Cited by 2
Romanzini, M., Reichert, F. F., Ronque, Ê. R. V., Lopes, A. S., & Petrosky, E. L. (2012) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · doi:10.12820/rbafs.v.16n1p31-36 · Cited by 4
Scaglia, H. E., Aquilano, Buccini, G., Chichizola, C., Corazza, N., Corthey, C., Fuillerat, S., Guével, L., Ibanez, G., Lacoste, E. R., et al. (2012) · Revista Argentina de Endocrinología y Metabolismo · Cited by 2
Engbers, M. J., Cushman, M., Rosendaal, F. R., & Vlieg, A. V. H. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2012.04792.x · Cited by 2
Medición de la vulnerabilidad: el caso de la adicción a drogas ilícitas en Chihuahua, México
Córdova-Contreras, R. J., & Idrovo, Á. J. (2010) · región y sociedad · doi:10.22198/rys.2010.49.a428 · Cited by 2
Sartório, A., Agosti, F., Col, A. D., Castelnuovo, G., Manzoni, G. M., Molinari, E., & Impellizzeri, F. M. (2014) · Journal of Endocrinological Investigation · doi:10.1007/s40618-013-0010-4 · Cited by 2
Review of Statistical Evaluation of Measurement Errors by Dunn
Cox, N. J. (2004) · The Stata Journal Promoting communications on statistics and Stata · doi:10.1177/1536867x0400400410 · Cited by 2
Fiore, T., Lupidi, M., Androudi, S. N., Giansanti, F., Fruttini, D., & Cagini, C. (2015) · Ophthalmologica · doi:10.1159/000435841 · Cited by 2
Resulting Shifts in Percentile and Standard Placements after Comparison of the BOD POD and DXA
Heden, T. D., Shepard, S., Smith, J. D., Covington, K., & LeCheminant, J. D. (2008) · International journal of exercise science · doi:10.70252/eihl7353 · Cited by 2
Boucher, F., Pouletaut, P., Munting, E., & Tho, M. H. B. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12020-6_28 · Cited by 2
Gouthaman, M., Raman, R., Kadambi, A., Padmajakumari, R., Paul, P., & Sharma, T. (2005) · PubMed · Cited by 2
Semiautomatic quantification of left and right ventricular functions in magnetic resonance imaging
Capdevila, L. R. M., Tahoces, P. G., Souto, M., Martı́nez, A., & Vidal, J. (2010) · Computing in cardiology · Cited by 2
3-Tesla MR spectroscopy in patients subjected to bone marrow transplantation: clinical correlations
Sergiacomi, G., Gaspari, E., Taglieri, A., Meschini, A., Gisone, V., Cudillo, L., Arcese, W., & Simonetti, G. (2012) · La radiologia medica · doi:10.1007/s11547-012-0796-8 · Cited by 2
Assessment of fluctuating asymmetry in permanent dentition
Rehmani, S. N., & Fida, M. (2012) · Pakistan orthodontic journal · Cited by 2
de Aguiar, A. P., de Oliveira, J. C., Stefanelli, V. C., de Oliveira, M. G., de Azevedo, P. H. S. M., Baldissera, V., & Rodrigues-Bigaton, D. (2010) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 2
Validation of the haemoglobin colour scale for screening blood donors in Malawi.
M’baya, B., Mbingwani, I., Mgawi, L., Mkochi, V. L., Bates, I., White, S. A., & Allain, T. J. (2014) · PubMed Central · Cited by 2
Lucila Ohno-machado, A., Vinterbo, S. A., Dreiseitl, S., Jenssen, T.-K., & Kuo, W. P. (2002) · Europe PMC (PubMed Central) · Cited by 2
Postoperative Bestimmung des täglichen Energiebedarfs: Vergleich von zwei Methoden
Dummler, R., Zittermann, A., Schäfer, M., & Emmerich, M. (2013) · Der Anaesthesist · doi:10.1007/s00101-012-2120-3 · Cited by 2
Agreement studies: clarification
McAlinden, C., Khadka, J., & Pesudovs, K. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00929.x · Cited by 2
Materko, W., & Santos, E. L. (2013) · Americanae (AECID Library) · Cited by 2
Lai, X. J., Alexander, J., He, M., Yang, Z., & Suttle, C. (2012) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2012.00753.x · Cited by 2
Simulation of Potassium Extraction by Continuous Haemodiafiltration
Amaya, F., Fukui, M., Tsuruta, H., Kooguchi, K., & Shimosato, G. (2002) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0203000212 · Cited by 2
Son, J., Hwang, S., Lee, J., & Kim, Y. H. (2010) · Journal of Biomedical Engineering Research · Cited by 2
Reliability of the 30-seconds crossbar jumps water polo test in female players
Bampouras, T. M., & Marrin, K. (2010) · Insight (University of Cumbria) · Cited by 2
Furzán, J. A., Expósito, M., & Luchón, C. (2007) · Archivos Venezolanos de Puericultura y Pediatría · Cited by 2
Vahidy, S., Majumdar, S. R., & Padwal, R. S. (2015) · International Journal of Hypertension · doi:10.1155/2015/801709 · Cited by 2
Kim, H., Lee, H., Park, Y., Kyung, S., & Hee, S. (2015) · Veterinary Clinical Pathology · doi:10.1111/vcp.12267 · Cited by 2
Kowallick, J. T., Steinmetz, M., Schuster, A., Unterberg‐Buchwald, C., Nguyen, T.-T., Faßhauer, M., Staab, W., Hösch, O., Rosenberg, C., Paul, T., et al. (2015) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2015.11.001 · Cited by 2
Determination of peritoneal phosphate transport as a tool for controlling serum phosphorus.
López-Guerra, E. A., Rodríguez-García, V. H., & Rodríguez-Castellanos, F. E. (2014) · PubMed · doi:10.3265/nefrologia.pre2014.jun.12281 · Cited by 2
Inferring the Performance of Medical Imaging Algorithms
Hernández-Sabaté, A., Gil, D., Roche, D., Matsumoto, M. M. S., & Furuie, S. S. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23672-3_63 · Cited by 2
Propuesta de ecuaciones para predecir la composición corporal de ratas machos wistar
Cossio‐Bolaños, M., Gómez, R., Rojas, J. E., & Flores, H. (2011) · Anales de la Facultad de Medicina · doi:10.15381/anales.v71i2.80 · Cited by 2
Determination of Cerebrospinal Fluid Glucose with the Vitros DT60 II Dry Chemistry System
Fingerhut, R. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.9.2000 · Cited by 2
Sauvinet, V., Gabert, L., Alligier, M., Normand, S., Roth, H., Laville, M., & Desage, M. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5173 · Cited by 2
Correcting for Guessing on Multiple‐Choice Exams
Chambers, D. W., Prihoda, T. J., Pinckard, R. N., McMahan, C. A., & Jones, A. C. (2007) · Journal of Dental Education · doi:10.1002/j.0022-0337.2007.71.2.tb04265.x · Cited by 2
Tøndevold, N., Reving, S., Møller, N., & Zerahn, B. (2011) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2011.01076.x · Cited by 2
Bräuer, A., Gassner, S., Koch, J., Heise, D., & Quintel, M. (2011) · ISRN Anesthesiology · doi:10.5402/2011/620905 · Cited by 2
A way to improve the reproducibility of measurements of myocardial velocity gradients
Poerner, T. C., Goebel, B., Vilardi, S., Borggrefe, M. M., & Haase, K. K. (2004) · International journal of cardiac imaging · doi:10.1023/b:caim.0000021942.15341.bf · Cited by 2
Clinical Usefulness of the Second Derivative of a Photoplethysmogram Waveform(SDPTG)
Oh, H. L., Cho, J. M., Jin, E., Kang, H. S., Choue, C. W., Kim, K. S., Song, J. S., & Bae, J. H. (2003) · Korean Circulation Journal · doi:10.4070/kcj.2003.33.3.233 · Cited by 2
Hayashi, H., Izumi, C., Takahashi, S., Uchikoshi, M., Yamazaki, R., Asanuma, T., Ishikura, F., Beppu, S., & Nakatani, S. (2010) · Journal of Echocardiography · doi:10.1007/s12574-010-0077-2 · Cited by 2
Wilson, R. A. A., Kolobe, T. H. A., Arnold, S. H., & McEwen, I. R. (2014) · Physical & Occupational Therapy In Pediatrics · doi:10.3109/01942638.2014.975310 · Cited by 2
Koff, M. F., Stanley, D. W., Weishaar, P., Amrami, K. K., & Kaufman, K. R. (2010) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim735 · Cited by 2
Nagasawa, Y., & Demura, S. (2010) · Perceptual and Motor Skills · doi:10.2466/pms.110.2.366-378 · Cited by 2
Srivannaboon, S., Chirapapaisan, C., Nantasri, P., Chongchareon, M., & Chonpimai, P. (2013) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-012-2222-2 · Cited by 3
ESTIMATING THE MEAN BLOOD FLOW OF ARM BASED ON WINDKESSEL MODEL
Liu, S.-H., Cheng, D., & Wang, J.-J. (2011) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s101623721100275x · Cited by 2
Özkaya, A., Alkın, Z., Durusoy, G. K., Karaküçük, Y., Perente, İ., Yazıcı, A. T., & Demirok, A. (2014) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2013.11.013 · Cited by 2
Austin, P. C., Donovan, L. R., Yun, L., & Tu, J. V. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.04.010 · Cited by 2
Automated spatial alignment of 3D torso images
Bose, A., Shah, S. K., Reece, G. P., Crosby, M. A., Beahm, E. K., Fingeret, M. C., Markey, M. K., & Merchant, F. A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6092086 · Cited by 2
La correction du débit en présence d’une fuite entre trachée et sonde endotrachéale
Bijaoui, E., Carry, P.-Y., Eberhard, A., Andrini, P., Perdrix, J. P., & Baconnicr, P. (1997) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013012 · Cited by 2
Arraiza, M., Azcárate, P., Arias, J., Cecco, C. N. D., Pueyo, J. C., Rábago, G., & Bastarrika, G. (2011) · Radiología · doi:10.1016/j.rx.2011.05.012 · Cited by 2
Performance of automated air tonometry under hypothermia
Weiß, M., Dullenkopf, A., & Hasenclever, P. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04216.x · Cited by 2
Using temporal-domain peak interval determination for video-based short-term heart rate measurement
Wu, Y., Ju, G.-H., Lee, T.-W., Liu, H.-S., & Chiu, Y.-L. (2013) · Asia-Pacific Signal and Information Processing Association Annual Summit and Conference (APSIPA ASC) · doi:10.1109/apsipa.2013.6694163 · Cited by 2
Rekič, A., Breznik, M., & Cvenkel, B. (2007) · International Ophthalmology · doi:10.1007/s10792-007-9051-z · Cited by 2
Khirani, S., Biot, L., Lavagne, P., Duguet, A., Similowski, T., & Baconnier, P. (2004) · Acta Biotheoretica · doi:10.1023/b:acbi.0000046596.43503.36 · Cited by 2
Flynn, D. M., Wolfgang, E. A., Raunig, D. L., & Knight, D. R. (2006) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2006.02.001 · Cited by 2
Maternal reporting of birthweight in a Peruvian shanty town.
Diaz, J. F. D. L. J., Gilman, R. H., & Cabrera, L. (1993) · American Journal of Public Health · doi:10.2105/ajph.83.8.1177 · Cited by 2
Murayama, I., Miyano, A., Sasaki, Y., Hirata, T., ICHIJO, T., Satoh, H., Sato, S., & Furuhama, K. (2013) · Journal of Animal Science · doi:10.2527/jas.2013-6817 · Cited by 2
Accuracy and precision of buccal pulse oximetry
Jong, M. J. D., Schmelz, J. O., Evers, K., Bradshaw, P., McKnight, K., & Bridges, E. J. (2010) · Heart & Lung · doi:10.1016/j.hrtlng.2009.12.002 · Cited by 2
Wolowich, W. R., & Steinberg, J. G. (2012) · Clinical Therapeutics · doi:10.1016/j.clinthera.2012.02.005 · Cited by 2
On-body antenna for vital signs and heart rate variability monitoring
Tariq, A., & Ghafouri‐Shiraz, H. (2011) · Loughborough Antennas & Propagation Conference (LAPC) · doi:10.1109/lapc.2011.6114145 · Cited by 2
Chacko, Y., Haladyn, J. K., Smith, D. M., & Lim, R. (2013) · Heart Asia · doi:10.1136/heartasia-2013-010312 · Cited by 2
Rousselon, S., Coat, M., Nguyen, B.-V., Gouny, P., Nowak, E., Wargnier, J. P., Arvieux, C. C., & Guéret, G. (2010) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2010.11.008 · Cited by 2
Collignon, C. M., Heiene, R., Quéau, Y., Reynolds, B., Craig, A. J., Concordet, D., Harran, N. X., Risøen, U., Balouka, D., Faucher, M. R., et al. (2012) · American Journal of Veterinary Research · doi:10.2460/ajvr.73.11.1841 · Cited by 4
Hegazy, A. M., Akbar, M. A. J., Al-Sayegh, A., & Abdulkader, B. A. (2006) · Medical Principles and Practice · doi:10.1159/000096139 · Cited by 2
Validación de un nuevo método de análisis digital de superficies
Echeverría, J. M. (2006) · Cirugía Plástica Ibero-Latinoamericana · doi:10.4321/s0376-78922006000200001 · Cited by 2
Zhang, Y., Xing, Z., Liu, Y., She, D., Zeng, Z., & Cao, D. (2014) · Abdominal Imaging · doi:10.1007/s00261-014-0126-9 · Cited by 2
Daurès, M.-F., Vallat, C., Combescure, C., & Cristol, J. (2009) · Biotechnology & Biotechnological Equipment · doi:10.1080/13102818.2009.10817650 · Cited by 2
Assessment of dynamic walking balance in children with acquired brain injury
Alderson, L. M., Watson, T., & Main, E. (2007) · Physical Therapy Reviews · doi:10.1179/108331907x174943 · Cited by 3
Basic and Clinical Science Course: complete set
Dick, A. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.079632 · Cited by 2
Effect of lotrafilcon A silicone hydrogel contact lens on intraocular pressure measurement
García‐Resúa, C., García-Montero, S., Pena‐Verdeal, H., Gilino, J., Yebra‐Pimentel, E., & Giraldez, M. J. (2014) · Optometry Reports · doi:10.4081/optometry.2014.1846 · Cited by 2
Jørgensen, L. G. M., Petersen, P. H., & Brandslund, I. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.057 · Cited by 2
Broholm, R., Wiinberg, N., & Simonsen, L. (2014) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2014.903431 · Cited by 2
Ultrasonic measurement of bone thickness for spinal surgery
Yamada, M., Moriya, H., Iino, T., Kasai, Y., Sudo, A., & Uchida, A. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2429 · Cited by 2
Ant Colony Optimization for Creating Digital Signature of Network Segments Using Flow Analysis
Carvalho, L. F., Zacaron, A. M., Adaniya, M. H. A. C., & Proença, M. L. (2012) · International Conference of the Chilean Computer Science Society (SCCC) · doi:10.1109/sccc.2012.27 · Cited by 2
Kuwabara, M., Narumi, Y., Takahashi, S., Sato, Y., Kim, T., Murakami, T., & Nakamura, H. (2006) · Radiation Medicine · doi:10.1007/s11604-005-1544-y · Cited by 2
Gavarry, O., Aguer, C., Delextrat, A. A., Lentin, G., Ayme, K., & Boussuges, A. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1021274 · Cited by 3
The effect of challenge method on methacholine-induced changes in sensitivity and air trapping
Segura, C., Prieto, L., López, V., Barato, D., Perez, C., & Marín, J. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.07.008 · Cited by 2
Reubrecht, V., Dingemans, G., Gache, A., Langeron, O., Faillie, J., GARDES, G., Bengler, C., Lefrant, J. Y., & Müller, L. (2011) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2011.07.018 · Cited by 2
Absence of age-related optic disk changes in young children with optic nerve hypoplasia
Sutedja, J., Garcia-Filion, P. C., Fink, C., & Borchert, M. (2014) · Eye · doi:10.1038/eye.2014.12 · Cited by 2
Measuring solids concentrations in urban stormwater and snowmelt: a new operational procedure
Nordqvist, K., Galfi, H., Österlund, H., Maršálek, J., Westerlund, C., & Viklander, M. (2014) · Environmental Science Processes & Impacts · doi:10.1039/c4em00204k · Cited by 2
Compound muscle action potential of the external anal sphincter
Nockolds, C. L., Hosker, G. L., & Kiff, E. S. (2013) · Colorectal Disease · doi:10.1111/codi.12315 · Cited by 2
Olivares, P. R., Pérez-Sousa, M. Á., Cruz, B. D. P., Delgado-Gil, S., Domínguez‐Muñoz, F. J., & Parraça, J. A. (2014) · Revista Colombiana de Reumatología · doi:10.1016/s0121-8123(14)70151-3 · Cited by 2
Krauß, I., List, R., Janßen, P., Maiwald, C., Grau, S., Horstmann, T., & Stacoff, A. (2010) · Footwear Science · doi:10.1080/19424281003772971 · Cited by 2
Validation of a Nonexercise Prediction Equation of Anaerobic Power
Stickley, C. D., Wages, J. J., Kimura, I. F., & Hetzler, R. K. (2011) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318243fa1f · Cited by 2
Validation of the Measurement of Haemodialysis Access Flow Using a Haemoglobin Dilution Test
Jiang, S., Clayton, P. A., Maguire, A., & Talaulikar, G. S. (2011) · Blood Purification · doi:10.1159/000323554 · Cited by 2
Dohgomori, H., Arikawa, K., & Kanmura, Y. (2004) · Journal of Anesthesia · doi:10.1007/s00540-003-0209-1 · Cited by 2
Validação das equações que estimam a taxa metabólica de repouso em adolescentes meninas
da Fonseca, P. H. S., Duarte, M. D. F. D. S., & Barbetta, P. A. (2010) · Arquivos Brasileiros de Endocrinologia & Metabologia · doi:10.1590/s0004-27302010000100006 · Cited by 6
The Competence of Fieldwork Students in Administering the Barthel Index
Yang, Y. J., Tsai, L. S., Wu, Y.-H., Hsieh, Y., Hsieh, C., & Howe, T.-H. (2008) · Hong Kong Journal of Occupational Therapy · doi:10.1016/s1569-1861(08)70010-x · Cited by 2
Saur, J., Kraus, F., Brade, J., Haghi, D., Behnes, M., Hoffmann, U., Borggrefe, M. M., Kaden, J. J., & Trinkmann, F. (2013) · Lung · doi:10.1007/s00408-013-9494-0 · Cited by 2
Utility of the surface ECG before VDD pacemaker implantation
Burri, H., Noble, S., Sunthorn, H., Dorsaz, P. ‐., Vieira, I., & Shah, D. C. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.05.006 · Cited by 2
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.