STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 42,201–42,300 of 47,868
Botero, P., Cuesta, D., Agudelo, S., Hincapie, C., & Ramírez, C. S. (2014) · Revista Facultad de Odontología Universidad de Antioquia · Cited by 1
Effects of Retinal Angiography on Optical Coherence Tomography Measurements
Jo, Y. J., Lim, H., Lee, S., & Kim, J. (2015) · Ophthalmologica · doi:10.1159/000381788 · Cited by 1
Osada, T. (2013) · InTech eBooks · doi:10.5772/53239 · Cited by 1
Chapter 23 Reference value determination
Robinson, L. R. (2006) · Handbook of clinical neurophysiology · doi:10.1016/s1567-4231(09)70084-x · Cited by 1
The validity and reliability of the handheld SW-100 autokeratometer
Iyamu, E., & Amiebenomo, O. M.-A. (2015) · African vision and eye health · doi:10.4102/aveh.v74i1.26 · Cited by 2
Which method is the best for estimating platelet count?
Lazreg, H., Bennaoum, M. N., Adda, A., & Brahimi, M. (2013) · National Journal of Physiology Pharmacy and Pharmacology · doi:10.5455/njppp.2014.4.041220133 · Cited by 1
Tantisaranon, P., Chayanunnukul, W., & Bodhikul, A. (2013) · Warasan Theknik Kanphaet · Cited by 1
Westling, C. E. I., Barker, L., Healy, A., Needham, R., Witchel, H. J., & Chockalingam, N. (2013) · Electronic workshops in computing · doi:10.14236/ewic/eva2013.17 · Cited by 1
Seidi, F., Minoonejad, H., & Youdas, J. W. (2015) · Journal of Back and Musculoskeletal Rehabilitation · doi:10.3233/bmr-140521 · Cited by 1
VOGT, F. M., den Bergh, R. V., Bernasconi, A. R., Moyo, B., Havazvidi, L., Bastard, M., Flévaud, L., Taziwa, F., Makondo, E., & Mtapuri‐Zinyowera, S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0136537 · Cited by 1
Model-based Monitoring of Septic Shock Treated with Large-pore Hemofiltration Therapy
Revie, J. A., Stevenson, D. J., Chase, J. G., Lambermont, B. C., Ghuysen, A., Kolh, P. H., Shaw, G. M., & Desaive, T. (2012) · IFAC Proceedings Volumes · doi:10.3182/20120829-3-hu-2029.00013 · Cited by 1
久保, 大., 佐藤, 正., 宏介, 柏., 中川, 修., 藤井, 隆., 田中, 順., & 田中, 昌. (2013) · 歯科医学 · doi:10.18905/shikaigaku.76.2_83 · Cited by 1
Tomson, R., Fridolin, I., & Luman, M. (2015) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000415 · Cited by 3
Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering
James, J., Tiwari, L. K., Upadhyay, P. K., Sreenivas, V., Bhambhani, V., & Puliyel, J. M. (2006) · BMC Pediatrics · doi:10.1186/1471-2431-6-14 · Cited by 1
Miranda, A. L. N., Lopes, K. C., Carletti, L., Peres, A. J., Mill, J. G., & Lunz, W. (2015) · journal of physical education · doi:10.4025/reveducfis.v26i1.22603 · Cited by 2
Developing a Protocol for Medical Student-Organized Community-Based Hypertension Screening Programs
Varshney, V. P., Harrison, T. G., Szymczakowski, M., Grossi, M., & Jones, C. (2013) · International Journal of Medical Students · doi:10.5195/ijms.2013.12 · Cited by 1
Aristei, C., Palumbo, I., Falcinelli, L., Crisci, R., Cardinali, L., Palumbo, B., Lancellotta, V., Montesi, G., Gobbi, G., Zucchetti, C., et al. (2015) · Radiation Oncology · doi:10.1186/s13014-015-0487-4 · Cited by 1
The carbon dioxide production rate assumption biases gastric emptying parameters in healthy adults
Markey, O., & Shafat, A. (2013) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6478 · Cited by 3
Toplak, I., Rihtarič, D., Hostnik, P., & Mrkun, J. (2015) · Slovenian Veterinary Research · doi:10.26873/svr-24682-2015 · Cited by 1
Landeros-Olvera, E., Salazar-González, B. C., & López-Alvarenga, J. C. (2015) · Aquichan · doi:10.5294/aqui.2015.15.1.5 · Cited by 1
Santos-Martínez, L.-E., Martínez-Guerra, M. L., Duran, A., Rodríguez, F., Gotés, J., Roquet, I., López, L. A., Pulido, A., Lupi‐Herrera, E., Bautista, E., et al. (2009) · PubMed · Cited by 1
Gomes, E. P. S. G., Rochitte, C. E., Azevedo, C. F., Lemos, P. A., Gutierrez, P. S., & César, L. A. M. (2014) · The Open Cardiovascular Medicine Journal · doi:10.2174/1874192401408010026 · Cited by 1
Serum IGF-1 levels measured by different ELISA assays and IRMA - a comparability study
Stoeva, I., Aroyo, A., Emilova, R., Pashova, S., Abadshieva, Z., & Кirilov, G. (2015) · Scripta Scientifica Medica · doi:10.14748/ssm.v47i1.1061 · Cited by 1
Harada, K., Tamura, M., & Toyono, M. (2006) · Pediatric Cardiology · doi:10.1007/s00246-003-0651-8 · Cited by 1
May, J. M., Kyriacou, P. A., & Petros, A. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610086 · Cited by 1
VALIDATION OF AN ERYTHROCYTE SEDIMENTATION RATE ANALYZER WITH MODIFIED WESTERGREN METHOD
Patil, A., Deepak Nayak, M., Belurkar, S., & SeemitrVerma, S. (2013) · Journal of Evolution of Medical and Dental Sciences · doi:10.14260/jemds/255 · Cited by 1
Burkhardt, H., & Weiß, C. (2008) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510701601665 · Cited by 1
Martin, D., Cooper, S. B., Sale, C., Compton, G., & Elliott-Sale, K. J. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.986504 · Cited by 2
Evaluation of a Fully Automated Method for the Determination of Sirolimus
Chozas, J. M. V., Godino, A. S.-B., González, J. R., Morales, L. S., Yagüe, P. M. D. A., & Fernández, C. C. (2010) · Transplantation Proceedings · doi:10.1016/j.transproceed.2010.07.065 · Cited by 1
Faucher, M., Poiraudeau, S., Lefèvre‐Colau, M., Rannou, F., Fermanian, J., & Revel, M. (2003) · Revue du Rhumatisme · doi:10.1016/s1169-8330(03)00154-6 · Cited by 1
Espessura central da córnea e a medida da pressão intra-ocular com diferentes tonômetros
Kitice, P. Y., Nunes, T. H. C., Giustina, E. D., de Barros, R. A., Filho, W. G. A., & Rehder, J. R. C. L. (2007) · Revista Brasileira de Oftalmologia · doi:10.1590/s0034-72802007000600005 · Cited by 4
Serafin, Z., Laskowska, K., Marzec, M., Sinjab, T. A., Lasek, W., & Włodarczyk, Z. (2009) · Acta Radiologica · doi:10.1080/02841850802716701 · Cited by 1
Fregonasse, T., Bottaro, M., Novaes, J. D. S., Oliveira, R., & de Melo, G. F. (2003) · Fitness & Performance Journal · doi:10.3900/fpj.2.2.97.e · Cited by 1
Cheng, H., Lang, D. S. P., Pearson, A., & Worthley, S. G. (2011) · JBI Library of Systematic Reviews · doi:10.11124/01938924-201109520-00001 · Cited by 1
Knowledge acquisition and its determinants: Malaysian international alliance experience
Hashim, F., & Bakar, A. R. A. (2009) · J for Global Business Advancement · doi:10.1504/jgba.2009.028705 · Cited by 1
Moreno, M. A., Paris, J. V., Pereira, R. D. N., Zamunér, A. R., de Camargo, T. M., & de Barros, R. M. L. (2014) · Fisioterapia em Movimento · doi:10.1590/0103-5150.027.003.ao07 · Cited by 1
Roerig, A., Carlson, R., & Tipold, A. (2012) · Research in Veterinary Science · doi:10.1016/j.rvsc.2012.07.013 · Cited by 1
Suárez, L. M., Gayarre, N. G., del Riego, J. M. C., Pita, M. P., Lavandeira, D. F., & Rúa, R. R. (2012) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2012.07.001 · Cited by 1
Guadalix, S., Martínez-Conde, L., Diaz‐Guerra, G. M., Vargas, C., & Hawkins, F. G. (2013) · Revista de Osteoporosis y Metabolismo Mineral · doi:10.4321/s1889-836x2013000100004 · Cited by 1
Validation of Neutron Activation as a Novel Method to Determine Glomerular Filtration Rate
Mandelbrot, D. A., Dhaliwal, S. K., Evan, N. R., Licho, R., Reinhardt, C. P., & Jaffry, S. (2007) · Nephron Clinical Practice · doi:10.1159/000109820 · Cited by 1
Elías, A., Melim, R. S., Frizera, A., Bastos-Filho, T., & de Souza, F. S. S. (2012) · ISSNIP Biosignals and Biorobotics Conference: Biosignals and Robotics for Better and Safer Living · doi:10.1109/brc.2012.6222164 · Cited by 1
Intraosseous blood aspirates analysed by a portable cartridge-based device
Strandberg, G., Larsson, A., Lipcsey, M., & Eriksson, M. B. (2011) · Critical Care · doi:10.1186/cc9558 · Cited by 1
Champely, S., Blache, Y., Campo, M., Rota, S., Monteil, K., & Rogowski, I. (2013) · Movement & Sport Sciences - Science & Motricité · doi:10.1051/sm/2012042 · Cited by 1
Einfluss der Herzfrequenzänderung auf die Reproduzierbarkeit der Liquorflussmessungen im Aquädukt
Bock, A., Geske, R., & Schnackenburg, B. (2003) · Clinical Neuroradiology · doi:10.1007/s00062-003-4345-7 · Cited by 1
Machann, W., Geier, O. M., Koeppe, S., O’Donnell, T., Greiser, A., Breunig, F., Sandstede, J. J. W., Hahn, D., Köstler, H., & Beer, M. (2013) · Acta Radiologica · doi:10.1177/0284185113505275 · Cited by 1
Kanauchi, M., & Kanauchi, K. (2010) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2010.02.005 · Cited by 1
Estimation of height from knee-heel length in middle age Caucasian adults
Ritz, P., Vol, S., Goxe, D., Quentel-Soroko, M. F., Berrut, G., & Tichet, J. (2007) · e-SPEN the European e-Journal of Clinical Nutrition and Metabolism · doi:10.1016/j.eclnm.2006.11.002 · Cited by 1
Ir-truefisp: A New Dce-mri Approach in Comparison with 3d-flash Multi Flip Angle Method
Büchert, M., & Mross, K. B. (2012) · Magnetic Resonance Insights · doi:10.4137/mri.s9832 · Cited by 1
Reproducibility of two13CO2breath tests dedicated to assess pancreatic exocrine function
JONDERKO, K., Kamińska, M., Kasicka-Jonderko, A., Bożek, M., Radosz, M., Szostak, K., & Błońska‐Fajfrowska, B. (2013) · Isotopes in Environmental and Health Studies · doi:10.1080/10256016.2013.750244 · Cited by 1
Pulse oximetry of body cavities and organs
Kyriacou, P. A., Hickey, M., & Phillips, J. P. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610088 · Cited by 1
Almeida, V., Borba, J., Pereira, T., Pereira, H. C., Cardoso, J. M. R., & Correia, C. M. B. A. (2012) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng.2012.6331339 · Cited by 1
Simó, J. M., Camps, J., Martín, S., Pedro‐Botet, J., Ferré, N., Gómez-Bertomeu, F., & Joven, J. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.205 · Cited by 1
Geomini, P. M. A. J., MOL, B.-W. J., Bremer, G. L., & Brölmann, H. A. M. (2000) · Journal of Gynecologic Surgery · doi:10.1089/gyn.2000.16.79 · Cited by 1
Provyn, S., Sesboüé, B., Sutton, L., Scafoglieri, A., Tresignie, J., Bautmans, I., & Clarys, J. P. (2010) · Science & Sports · doi:10.1016/j.scispo.2010.08.005 · Cited by 1
COMPOSICIÓN CORPORAL DE MUJERES OBESAS DE 20 A 40 AÑOS DE EDAD DE NIVEL SOCIOECONÓMICO ALTO Y BAJO
Marcela Ruiz de La, F., & de la Maza, M. P. (2007) · Revista chilena de nutrición · doi:10.4067/s0717-75182007000300009 · Cited by 1
Awad, S., Cui, H. W., Wright, J. W., Jackson, S. J., Macdonald, I. A., & Lobo, D. N. (2012) · e-SPEN Journal · doi:10.1016/j.eclnm.2011.12.009 · Cited by 1
Hidaka, H., Wang, G., Nakazawa, T., Kida, M., Yanagihara, M., Fujii, S., Shibuya, A., & Koizumi, W. (2013) · Journal of Medical Ultrasonics · doi:10.1007/s10396-013-0443-6 · Cited by 1
Gray, R. G., Cabreriza, S. E., Quinn, T. A., Weinberg, A. D., & Spotnitz, H. M. (2010) · ASAIO Journal · doi:10.1097/mat.0b013e3181d823a1 · Cited by 1
Automatic Identification of the Lumen Border in Intravascular Ultrasound Images
Park, J.-O., Ko, B. C., Park, H.-J., & Nam, J.-Y. (2012) · The KIPS Transactions PartB · doi:10.3745/kipstb.2012.19b.3.201 · Cited by 1
Have You Tested Your Goldmann Tonometer Today?
Choudhari, N. S., George, R. J., & Vijaya, L. (2008) · JOURNAL OF CURRENT GLAUCOMA PRACTICE · doi:10.5005/jp-journals-10008-1027 · Cited by 1
Gribok, A. V., Rumpler, W. V., Hines, J. W., Hoyt, R. W., & Buller, M. J. (2014) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2014.11 · Cited by 1
Joffe, A. M., Healey, L., Khandelwal, N., Hallman, M. R., Cleve, W. V., & Treggiari, M. M. (2013) · Neurocritical Care · doi:10.1007/s12028-013-9915-1 · Cited by 1
Neural network technology to predict intracellular water volume
Chiu, J.-S., CHEN, C.-A., LEE, C.-H., Li, Y., LIN, Y.-F., WANG, Y.-F., & Yu, F.-C. (2006) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2005.00761.x · Cited by 1
Pessana, F., Venialgo, E., Rubstein, J., & Furfaro, A. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626719 · Cited by 1
Wireless vital signs from a life-supporting medical device exposed to electromagnetic disturbance
Øyri, K., Chávez‐Santiago, R., Støa, S., Martinsen, Ø. G., Balasingham, I., & Fosse, E. T. (2014) · Minimally Invasive Therapy & Allied Technologies · doi:10.3109/13645706.2014.931869 · Cited by 1
Possibility of non-invasive blood pressure estimation by measurements of force and arteries diameter
Veye, F., Mestre, S., Pérez‐Martin, A., & Triboulet, J. (2014) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2014.6864289 · Cited by 1
REPEATABILITY OF SOIL APPARENT ELECTRICAL CONDUCTIVITY MEASURED BY A COULTER SENSOR
Jabro, J. D., Evans, R. G., Stevens, W. B., & Iversen, W. M. (2008) · Soil Science · doi:10.1097/ss.0b013e318159a608 · Cited by 1
Estimation of peak oxygen uptake from peak power output in able-bodied and paraplegic individuals
Al-Rahamneh, H. Q., & Eston, R. G. (2012) · Journal of Exercise Science & Fitness · doi:10.1016/j.jesf.2012.10.004 · Cited by 1
Elmstedt, N., Lind, B., Ferm‐Widlund, K., Westgren, M., & Brodin, L. (2013) · Journal of Biomedical Graphics and Computing · doi:10.5430/jbgc.v3n2p16 · Cited by 1
PIEPSZ, A. (1994) · Acta Paediatrica · doi:10.1111/j.1651-2227.1994.tb18271.x · Cited by 1
Accuracy of a portable electroneurometer for measuring distal motor latency
Tanaka, H., Hashizume, H., McCown, C., Senda, M., Nishida, K., & Inoue, H. (2005) · Journal of Orthopaedic Science · doi:10.1007/s00776-005-0928-2 · Cited by 1
Accuracy of simple predictive equations for visceral fat area after 8 weeks of training
Demura, S., Sato, S., Yamaji, S., Murooka, T., & Nakai, M. (2010) · Journal of Sports Sciences · doi:10.1080/02640411003792703 · Cited by 1
Assessing Assay Variability of Pesticide Metabolites in the Presence of Heavy Left-Censoring
Chen, H., Quandt, S. A., Barr, D. B., & Arcury, T. A. (2015) · Journal of Agricultural Biological and Environmental Statistics · doi:10.1007/s13253-015-0196-3 · Cited by 1
Assessment of the RPE as a measure of cardiovascular fitness in patients with low back pain
Finucane, L. M., Fiddler, H., & Lindfield, H. (2005) · International Journal of Therapy and Rehabilitation · doi:10.12968/ijtr.2005.12.3.19554 · Cited by 1
Safari, R., Rowe, P. J., & Buis, A. W. P. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.09.0159 · Cited by 1
Umeda, A., Kawasaki, K., Abe, T., Yamane, T., & Okada, Y. (2014) · International Journal of Clinical Medicine · doi:10.4236/ijcm.2014.52014 · Cited by 1
An update on genetic parameters for facial eczema susceptibility in New Zealand dairy cattle
Cullen, N. G., & Ruakura, A. (2011) · Proceedings of the New Zealand Society of Animal Production · Cited by 1
Nagadia, Q., Prajapati, N., Gosai, D. K., & Mehariya, K. M. (2013) · Indian Journal of Scientific Research · Cited by 1
Williams, N. H., Amoakwa, E., Belcher, J., Burton, K. A., Hendry, M., Lewis, R. A., Hood, K., Bennett, P. D., Neal, R. D., & Wilkinson, C. (2012) · International Musculoskeletal Medicine · doi:10.1179/1753615411y.0000000014 · Cited by 2
Utility of novel volumetric intravascular ultrasound analysis software for coronary artery disease.
Tsumori, T., Kataoka, T., 小林, 芳., Xiaohui, G., Takeshita, H., Shirai, N., Matsumoto, R., Nakata, S., Ehara, S., & Yoshiyama, M. (2009) · PubMed · Cited by 1
Measuring cardiac output in hemodialysis patients
Gerwen, V. J. J. (2009) · Cited by 1
Klokker, L., Christensen, R., Osborne, R. H., Aaboe, J., Bliddal, H., & Henriksen, M. (2013) · OA Musculoskeletal Medicine · doi:10.13172/2052-9287-1-3-906 · Cited by 1
Lee, Y. J., Kim, J. M., & Park, D. (2010) · Annals of Laboratory Medicine · doi:10.3343/kjlm.2010.30.1.9 · Cited by 1
The Aortic, Mitral and Tricuspid Annuli and Their Velocities: A Comparative Echocardiographic Study
Nygren, B.-M. (2014) · Journal of Clinical & Experimental Cardiology · doi:10.4172/2155-9880.1000327 · Cited by 1
Thoracic electrical bioimpedance: a non-invasive measure of cardiac output for porcine research
Broomhead, C. J., Wright, S. J., Kiff, K., & Withington, P. S. (1998) · Laboratory Animals · doi:10.1258/002367798780559266 · Cited by 1
Beidohriger Zahlentest im Störgeräusch nach Sauer
Braun, T., Leisering, B., Krause, E. T., Schorn, K., & Hempel, J. M. (2012) · HNO · doi:10.1007/s00106-012-2544-8 · Cited by 1
Regarding the validity of methods of body composition assessment in young and older men and women
Watson, W. S. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.6.2518 · Cited by 1
Influence of rigid coregistration of PET and CT data on metabolic volumetry: a user’s perspective
Steffen, I. G., Hofheinz, F., Rogasch, J. M. M., Furth, C., Amthauer, H., & Ruf, J. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-85 · Cited by 1
Thakar, M. R., Mahajan, B., Joshi, T., Sane, S. S., & Paranjape, R. (2013) · Europe PMC (PubMed Central) · Cited by 1
Nusmeier, A., Vrancken, S. L. A. G., de Boode, W. P., van der Hoeven, J. G., & Lemson, J. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet021 · Cited by 1
Vreede, A. P., Jones, A. N., & Hansen, K. E. (2015) · Nutrition Journal · doi:10.1186/s12937-015-0065-5 · Cited by 1
Comparative statistical analysis between two methods for the measurement of visceral fat in humans
Azpiroz-Leehan, J., Cadena, M., & Ramos-Ibáñez, N. (2013) · Pan American Health Care Exchanges · doi:10.1109/pahce.2013.6568304 · Cited by 1
Dukić, L., Šimundić, A.-M., & Malogorski, D. (2014) · Biochemia Medica · doi:10.11613/bm.2014.016 · Cited by 1
Wibault, J. (2015) · Linköping University medical dissertations · doi:10.3384/diss.diva-122695 · Cited by 3
Axillary Electronic and Galinstan Thermometer Measurements: A Comparison of Their Consistency
Lowe, J. C. (2009) · Cited by 1
Paludo, A. C., Batista, M. B., Serassuelo, H., Shigaki, G. B., Cyrino, E. S., & Ronque, Ê. R. V. (2015) · Revista Andaluza de Medicina del Deporte · doi:10.1016/j.ramd.2015.03.001 · Cited by 1
Analytical Performance and Quality Control of a Glucose Monitor System
Peyman, M. T., & Azari-Yam, A. (2011) · Iranian journal of pathology · Cited by 2
Chahar, P. S. (2013) · Cited by 1
Kobr, J., Třeška, V., Moláček, J., Kuntscher, V., Liška, V., & Slavík, Z. (2011) · Physiological Research · doi:10.33549/physiolres.932015 · Cited by 1
A statistical model to estimate potential yields in Persian walnut (Juglans regia L.)
Ojaghloo, B., Vahdati, K., Amiri, R., & Hassani, D. (2014) · Cited by 1
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.