STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 42,601–42,700 of 47,868
An approach to generate synthetic 4DCT datasets to benchmark Mid-Position implementations
Ghareeb, F., Boukerroui, D., Stroom, J. C., Jackson, E., Pereira, M. D., Gooding, M. J., & Greco, C. (2023) · Physica Medica · doi:10.1016/j.ejmp.2023.103144 · Cited by 1
Fat-Free Mass Index for body composition analysis in pediatric sport: a cross-sectional study
de Almeida‐Neto, P. F., da Costa, R. F., Cesário, T. D. M., Aidar, F. J., de Matos, D. G., Dantas, P. M. S., & Cabral, B. G. D. A. T. (2023) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.23.15377-1 · Cited by 1
Evaluation of the Italian version of the elderly mobility scale in older hospitalized patients
Nicolai, M., Casoni, E., Bertino, E., David, L., Polverigiani, C., Mallucci, F., Fioretti, P., Leonzi, S., Bevilacqua, R., Barbarossa, F., et al. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1274047 · Cited by 1
Developing First Native Regression Equations to Predict of Cardiorespiratory Fitness in Healthy Boys
Jalili, M., Nazem, F., & Qaragozlu, A. (2023) · Iranian Journal of Public Health · doi:10.18502/ijph.v52i12.14327 · Cited by 1
Huang, C., Nihey, F., Fukushi, K., Kajitani, H., Nozaki, Y., Ihara, K., & Nakahara, K. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340567 · Cited by 1
Body composition profile of Brazilian national circus school students
Bortoleto, M. A. C., Castro, A., & Bellotto, M. L. (2023) · Retos · doi:10.47197/retos.v52.101121 · Cited by 1
Whitehead, J. F., Periyasamy, S., Laeseke, P. F., Speidel, M. A., & Wagner, M. G. (2024) · Journal of medical imaging · doi:10.1117/1.jmi.11.1.013501 · Cited by 1
Accuracy testing of a novel obstetric blood loss quantifying device: A pilot study
Lutfi, A., Eustace, D., Faul, S., Greene, R. A., & Higgins, J. R. (2024) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.15385 · Cited by 1
Vargas-Domínguez, C., & Vázquez-García, J. C. (2023) · NCT Neumología y Cirugía de Tórax · doi:10.35366/114223 · Cited by 1
Harper, B., Shiraishi, M., & Soangra, R. (2023) · International Conference on Next Generation Electronics (NELEX) · doi:10.1109/nelex59773.2023.10421597 · Cited by 1
Sansatan, R., Kanlayanaphotporn, R., Jensen, M. P., Correia, H., & Janwantanakul, P. (2024) · Journal of Patient-Reported Outcomes · doi:10.1186/s41687-024-00702-2 · Cited by 1
Breast arterial calcification is associated with sarcopenia in peri- and post-menopausal women
Erkan, M., & Özcan, S. G. G. (2024) · Clinical Imaging · doi:10.1016/j.clinimag.2024.110143 · Cited by 1
Lee, D.-E., Kim, J., Han, S.-Y., & Kwon, O.-Y. (2024) · Physical Therapy Korea · doi:10.12674/ptk.2024.31.1.18 · Cited by 1
Sasidharan, A., Bhaskaran, R., Baiju, N. M., Rafi, A. M., & Innah, S. J. (2024) · The Journal of Clinical and Scientific Research · doi:10.4103/jcsr.jcsr_149_22 · Cited by 1
Mindfulness-Based Interventions: Teaching Assessment Criteria (MBI:TAC)
Sansom, S. A., & Crane, R. S. (2025) · Springer eBooks · doi:10.1007/978-3-030-77644-2_129-1 · Cited by 1
Ancillary Testing in Screening for Hydroxychloroquine and Chloroquine Retinopathy
Browning, D. J. (2014) · Springer eBooks · doi:10.1007/978-1-4939-0597-3_8 · Cited by 1
Bland-Altman Plots for Evaluating Agreement Between Solid Tumor Measurements
Moskowitz, C. S., & Gönen, M. (2011) · Collection of Biostatistics Research Archive · Cited by 1
Immunofluorescence vs immunochemiluminescent methods: AIA 2000 vs Immulite 2000
Cosma, C., Baggio, S., Casarotti, A., Zaninotto, M., Faggian, D., & Plebani, M. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.05.017 · Cited by 1
Reboundtonometrie nach vitreoretinaler Chirurgie
Rosentreter, A., Hoerster, R., Schick, T., Eter, N., Dietlein, T. S., & Fauser, S. (2015) · Der Ophthalmologe · doi:10.1007/s00347-015-0076-9 · Cited by 1
Sigh: tool to determine the respiratory viscoelastic properties.
Antonaglia, V., Peratoner, A., Simoni, L. D., Lucangelo, U., Gullo, A., & Zin, W. A. (2002) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1026277004613 · Cited by 1
Validation of the Pulmonary Function System for Use on the International Space Station
McCleary, F. A., Moore, A., & Hagan, R. (2007) · NASA Technical Reports Server (NASA) · Cited by 1
A Study in Computerized Translation Testing (CTT) for the Arabic Language
Kuhn, A. J. (2012) · ScholarsArchive (Brigham Young University) · Cited by 1
Ferraro, M., Stalder, S., Baur, H., Radlinger, L., & Rogan, S. (2015) · ARBOR - Bern University of Applied Sciences Repository · doi:10.24451/arbor.5700 · Cited by 1
Prins, S. A. (2005) · EUR Research Repository (Erasmus University Rotterdam) · Cited by 1
Quantification of Brain Aneurysm Dimensions from CTA for Surgical Planning of Coiling Interventions
Hernández, M., Frangi, A. F., & Sapiro, G. (2007) · Springer eBooks · doi:10.1007/0-306-48608-3_5 · Cited by 1
Dragesund, T. (2012) · NORA - Norwegian Open Research Archives · Cited by 3
The clinical value of total isovolumic time
Bajraktari, G. (2014) · DiVA at Umeå University (Umeå University) · Cited by 1
Danchin, N., Juillière, Y., Foley, D. P., & Serruys, P. W. J. C. (1994) · Developments in cardiovascular medicine · doi:10.1007/978-94-015-8358-9_9 · Cited by 1
Discriminant Validity of the Stress-Energy Questionnaire Regarding Work and Leisure TimePreprint
Hadžibajramović, E., Svensson, E., & Ahlborg, G. (2013) · RePEc: Research Papers in Economics · Cited by 1
McGurk, R. (2013) · DukeSpace (Duke University) · Cited by 1
Can Baroreflex Sensitivity be Assessed in a Fully Non-invasive Way?
Wichterle, D., Kára, T., & Malík, M. (1999) · Cardiac Electrophysiology Review · doi:10.1023/a:1009928203959 · Cited by 2
The Study of the Microcirculation using Orthogonal Polarization Spectral Imaging
Harris, A. G., Langer, S. W., & Meßmer, K. (2000) · Yearbook of intensive care and emergency medicine · doi:10.1007/978-3-662-13455-9_58 · Cited by 1
Repeat Ambulance Use by the Pediatric Patient † 372
Broxterman, K. J., Sapién, R. E., Fullerton, L., Olson, L. M., & Sklar, D. P. (1998) · Pediatric Research · doi:10.1203/00006450-199804001-00393 · Cited by 1
Bile Acid Induced Diarrhoea Pathophysiological and Clinical Aspects
Bajor, A. (2008) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 1
Magnetic navigation in percutaneous coronary and non-coronary interventions
Ramcharitar, S. (2008) · RePub (Erasmus University Rotterdam) · Cited by 1
Modification of midfoot bone stress with functional foot orthoses
Halstead, J. (2013) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 1
Volume flow measurements with a novel semi-automated 4D doppler ultrasound scanner
Forsberg, F., Liu, J. B., Stein, A. D., Deng, X., Ackerman, W., Herzog, D., Abend, K., & Needleman, L. (2005) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2004.1418251 · Cited by 1
Assessment of Trabecular Bone Microstructure using Dental Cone Beam CT
Ibrahim, N. (2014) · Digital Academic REpository of VU University Amsterdam (Vrije Universiteit Amsterdam) · Cited by 1
Note technique : validation des outils de monitorage du débit cardiaque
Squara, P., & Chiche, J. (2011) · Réanimation · doi:10.1007/s13546-011-0224-4 · Cited by 1
Pharmacodynamic Evaluation: Cardiovascular Methodologies
de Mey, C., & Hinder, M. (2010) · Springer eBooks · doi:10.1007/978-3-540-89891-7_31 · Cited by 1
Evaluation of Iohexol Clearance to Estimate Glomerular Filtration Rate in Normal Horse Foals
Gonda, K. A. (2002) · VTechWorks (Virginia Tech) · Cited by 1
Bower, K. S. (2007) · Defense Technical Information Center (DTIC) · Cited by 1
Approximation koronarer Strukturen in IVUS-Frames durch unscharfe elliptische Templates
Weichert, F., & Wilke, C. (2003) · Informatik aktuell · doi:10.1007/978-3-642-18993-7_90 · Cited by 1
Bayesian posterior probabilities: revisitedPreprint
Morrison, D. A. (2010) · arXiv (Cornell University) · doi:10.48550/arxiv.1001.3638 · Cited by 1
van Stralen, M., Voormolen, M. M., van Burken, G., Krenning, B. J., van Geuns, R., Angelié, E., van der Geest, R. J., Lancée, C. T., de Jong, N., van der Steen, A. F. W., et al. (2006) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2005.1603072 · Cited by 1
Design, reliability and validity of a paediatric rate of reading (PRR) chart.
Nirghin, U. (2012) · ResearchSpace (University of KwaZulu-Natal) · Cited by 2
Patcas, R. (2014) · Zurich Open Repository and Archive (University of Zurich) · Cited by 1
Biomechanical analysis of fixed bearing and mobile bearing total knee prostheses
Urwin, S. (2014) · Northumbria Research Link (Northumbria University) · Cited by 1
Measuring the Accuracy of Prognostic Judgments
Mackillop, W. J., Bartfay, E., & Groome, P. A. (2003) · Wiley eBooks · doi:10.1002/0471463736.tnmp10 · Cited by 1
Brorsson, S. (2008) · Hogskolan Ihalmstad (Halmstad University) · Cited by 5
Body composition and energy expenditure in men with schizophrenia
Sharpe, J.-K. (2007) · Faculty of Health · Cited by 1
A quantitative analysis of eye movement characteristics during the cover test
Barnard, N. A. S. (1999) · City Research Online (City University London) · Cited by 1
Attitudes of responsibility for musculoskeletal disorders
Larsson, M. E. H. (2009) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 2
Hiscox, R. (2013) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1
Comparação dos Lipocalibradores Baseline® e Harpenden® para a Medição de Pregas Cutâneas
Pinto, E. C. B., & Lopes, C. M. M. (2007) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 1
Effects of physical training on physical performance in frail elderly people
Rydwik, E. (2007) · Figshare · Cited by 1
Alhassan, M. (2014) · UWSpace (University of Waterloo) · Cited by 1
Hakim, A., & Karim, A. (2011) · Nottingham ePrints (University of Nottingham) · Cited by 1
Optical sensors for the in vivo assessment of flap perfusion in plastic surgery
Zaman, T. (2013) · City Research Online (City University London) · Cited by 1
Paediatric lung function testing : determinants and reference values
Koopman, M. (2011) · Utrecht University Repository (Utrecht University) · Cited by 1
Colvin, M. (2007) · Tuwhera (Auckland University of Technology) · Cited by 1
van der Wel, M. C., & Bakx, J. C. (2012) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.05.017 · Cited by 1
Estudo da anatomia do seio esfenoidal através da dissecção endoscópica em cadáveres
Filho, B. C. A. (2008) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.5.2008.tde-10072008-160428 · Cited by 1
Ordoñez, Y. N. F. (2009) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/6029 · Cited by 3
Ruiz, J. R. (2009) · Cited by 1
McCaughey, E. J. (2014) · Enlighten: Theses (The University of Glasgow) · Cited by 2
Automatic summarization of short fiction
Kazantseva, A. (2007) · uO Research (University of Ottawa) · doi:10.20381/ruor-12286 · Cited by 1
Develoment, evaluation and application of methods for mycotoxin analysis.
Limsuwan, S. (2013) · doi:10.53846/goediss-3855 · Cited by 1
The acute effects of Creatine Monohydrate loading on simulated soccer performance
Williams, J. (2007) · Tuwhera (Auckland University of Technology) · Cited by 1
Use of OCT and Oculus Pentacam HR as Aids to Semi-Scleral Contact Lens Fitting
Otchere, H. (2013) · UWSpace (University of Waterloo) · Cited by 1
Measuring physical fitness in persons with severe/profound intellectual and multiple disabilities
Waninge, A. (2011) · Data Archiving and Networked Services (DANS) · Cited by 1
Aspects on Image Quality in Radiologic Evaluation of the Urinary Tract
Lundin, M. (2012) · DiVA (Linkoping University) · Cited by 1
Categorical and Continuous Variables: Tests of Agreement
Goodman, N. (2005) · Wiley eBooks · doi:10.1002/9780470755945.ch9 · Cited by 1
Symposium on obesity (First Part).
Bastarrachea, R. A., Bouchard, C., Stunkard, A. J., Laviada‐Molina, H., & Heymsfield, S. B. (1999) · REVISTA BIOMÉDICA · doi:10.32776/revbiomed.v10i1.186 · Cited by 1
Prognostication and treatment decision-making in early breast cancer
Fiets, W. E. (2006) · Leiden Repository (Leiden University) · Cited by 1
Hallux valgus surgery : pidemiological aspects and clinical outcome
Saro, C. (2007) · Figshare · Cited by 1
Postmortem biochemistry - analysis of metabolic imbalance
Keltanen, T. (2015) · Helda - University of Helsinki Institutional Repository · Cited by 3
Self‐monitoring of blood glucose from abdominal skin: An extraordinary method
Holstein, A., Hinze, S., Perret, U., Nahrwold, D. A., & Egberts, E. (1999) · Practical Diabetes · doi:10.1002/pdi.1960160110 · Cited by 1
Automated Assessment of Area of Dense Tissue in the Breast: A Comparison with Human Estimation
Jeffries-Chung, C., Diffey, J., Berks, M., Morrison, J., Verow, R., Morris, J., Wilson, M., Boggis, C. R. M., Barr, N. B., Maxwell, A., et al. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-13666-5_23 · Cited by 1
Morales, M., Ferdeghini, E. M., Piacenti, M., Pelosi, G., Cerrai, T., Maggiore, Q., & Distante, A. (2002) · Computers in cardiology · doi:10.1109/cic.1996.542634 · Cited by 1
Wang, P. (2004) · Tuwhera (Auckland University of Technology) · Cited by 1
Understanding functioning and health in patients with whiplash-associated disorders
Schmitt, M. A. (2010) · Utrecht University Repository (Utrecht University) · Cited by 3
A Symmetry Hypothesis and Measurement Biases in the Factor Content of Trade
Puzzello, L. (2010) · Purdue e-Pubs (Purdue University System) · Cited by 1
Robbers‐Visser, D. (2005) · RePub (Erasmus University Rotterdam) · Cited by 1
Central and peripheral determinants of fatigue in acute hypoxia
Goodall, S. (2011) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 1
Schwendenwein, I., & de Arespacochaga, A. G. (2005) · Tierärztliche Praxis Ausgabe K Kleintiere / Heimtiere · doi:10.1055/s-0037-1622496 · Cited by 1
Development and validation of a digital quantitative orthoptics workstation
Shahimin, M. M. (2012) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1
QUANTIFICATION OF MARINE MEGAFAUNAL DISTRIBUTION PATTERNS USING A REMOTELY OPERATED VEHICLE
Parry, D. (2002) · PEARL (University of Plymouth) · doi:10.24382/4672 · Cited by 1
Hawezi, N. (2015) · Nottingham ePrints (University of Nottingham) · Cited by 2
Magnetic Resonance Spectroscopy as applied to epilepsy
Simister, R. J. (2012) · UCL Discovery (University College London) · Cited by 1
Cervical influence on dizziness and orientation
Malmström, E.-M. (2008) · Lund University Publications (Lund University) · Cited by 1
Exposure to some carcinogenic compounds in air, with special reference to wood smoke
Gustafson, P. (2009) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 1
Solomon, A. W. (2013) · LSHTM Research Online (London School of Hygiene and Tropical Medicine) · doi:10.17037/pubs.00878720 · Cited by 1
Ignell, C. (2015) · Lund University Publications (Lund University) · Cited by 3
Cardiac Magnetic Resonance Imaging in Ischemic Heart Disease
Kirschbaum, S. W. (2011) · EUR Research Repository (Erasmus University Rotterdam) · Cited by 1
Ettyang, G. A., Lichtenbelt, W. D. V. M., Saris, W. H. M., & Oloo, A. J. (2004) · South African Journal of Clinical Nutrition · doi:10.1080/16070658.2004.11734007 · Cited by 1
Etude cinématique in vivo de l'articulation trapézométacarpienne
Goubier, J. (2007) · HAL · Cited by 1
Bertulat, S. (2014) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-9463 · Cited by 1
[Transcranial Doppler reflects intracranial pressure].
Bellner, J., Romner, B., Reinstrup, P., Kristiansson, K.-A., Ryding, E., & Brandt, L. (2005) · PubMed · Cited by 1
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.