STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 42,301–42,400 of 47,868
Comparison of 2 methods to correct for peripheral nitric oxide exchange in the lungs.
Prieto, L. M., López, V., Barato, D., & Marín, J. (2013) · PubMed · Cited by 1
DONADIO, C. (2014) · Internal Medicine Open Access · doi:10.4172/2165-8048.1000178 · Cited by 1
Essers, I., van Tubergen, A. M., Heldmann, F., Baraliakos, X., Braun, J., Kiltz, U., & Boonen, A. E. R. C. H. (2015) · RMD Open · doi:10.1136/rmdopen-2015-000164 · Cited by 1
RELIABILITY OF KINEMATIC MEASUREMENTS DURING TREADMILL RUNNING
Muniz, A. M. D. S., Britto, P. A. D. A., Franco, D. M., Fontenelle, G., Limeira, G. A., ZYLBERBERG, M. P., Gerken, G., & Nadal, J. (2012) · ISBS - Conference Proceedings Archive · Cited by 1
ASSESSMENT OF SCORES IN DECISION MAKING IN METASTASES OF THE SPINE
Ferreira, M. V. D. O., Ueta, R. H. S., Curto, D. D., & Puertas, E. B. (2015) · Coluna/Columna · doi:10.1590/s1808-185120151404132726 · Cited by 1
Diabetes mellitus: metas Six Sigma para el control de calidad analítico
Terrés-Speziale, A. M. (2008) · Revista Latinoamericana de Patología Clínica y Medicina de Laboratorio · Cited by 1
Hipoglucemia del recien nacido
Williams, A. F. (1999) · Cited by 1
Predictive equations for skeletal muscle mass
Watson, W. S. (2001) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/73.5.993a · Cited by 1
McCann, G. P., Khan, J. N., Greenwood, J. P., Nazir, S. A., Dalby, M. C. D., Curzen, N. P., Hetherington, S. L., Kelly, D. J., Blackman, D. J., Ring, A., et al. (2016) · Efficacy and Mechanism Evaluation · doi:10.3310/eme03010 · Cited by 1
Reproducibility between conventional and digital periapical radiography for bone height measurement
Simancas‐Pallares, M., Rubio-Romero, J. A., & Cortés-Reyes, É. (2015) · Revista de la Facultad de Medicina · doi:10.15446/revfacmed.v63.n4.53224 · Cited by 1
Bindu, A., Kutty, P. M., Menon, A., Divya, P., & Jose, S. (2015) · Indian Journal of Child Health · doi:10.32677/ijch.2015.v02.i02.010 · Cited by 1
Upreti, D., Kyle, J., Simkhada, P. P., Thoulass, J., & McNeil, G. (2015) · Asian Journal of Agriculture and Food Sciences · Cited by 1
ACUTE EFFECTS OF DYNAMIC STRETCHING ON VERTICAL JUMP: A SYSTEMATIC REVIEW AND META-ANALYSIS
Marques, N. K., & Junior, M. (2014) · Cited by 1
Araújo, T., Aresta, G., Rouco, J., Ferreira, C., Azevedo, E. I., & Campilho, A. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-20801-5_39 · Cited by 1
Semi-automated calculation of intracranial haematoma volume with a new method
Cüce, F., Dandin, Ö., Teomete, U., Osman, O., Ergin, T., Tulum, G., & Aydın, O. U. (2016) · Injury · doi:10.1016/j.injury.2016.02.016 · Cited by 1
Tomizza, M. A., Jessome, M. A., Barbosa, J., BEATTIE, K. A., Bensen, W., Bobba, R. S., Cividino, A. A., Emond, P. D., Gordon, C. L., Hart, L. E., et al. (2015) · The Journal of Rheumatology · doi:10.3899/jrheum.141139 · Cited by 1
On XML Based Automated Function Point Analysis: An Effective Method to Assess Developer Productivity
Lent, J. S., & Qu, Y.-Z. (2014) · Lecture Notes on Software Engineering · doi:10.7763/lnse.2015.v3.199 · Cited by 1
Dmax method estimates lactate threshold in individuals with type 2 diabetes
Aguiar, S. D. S., Sousa, C. V., Sales, M. M., Filho, J. M. S., Sotero, R. D. C., Rosa, T. D. S., & Simões, H. G. (2016) · Sport Sciences for Health · doi:10.1007/s11332-016-0272-2 · Cited by 1
Davies, K. W. (2013) · Journal of Pharmaceutical and Scientific Innovation · doi:10.7897/2277-4572.02452 · Cited by 1
Development and Preliminary Validation of the Coma Arousal Communication Scale
Garin, J., Reina, M., DeiCas, P., & Rousseaux, M. (2015) · Journal of Head Trauma Rehabilitation · doi:10.1097/htr.0000000000000204 · Cited by 1
Quantificação semiautomática da velocidade do sangue em imagens de ultrassonografia Doppler
Higa, M., Pilon, P. E., Lage, S. H. G., & Gutierrez, M. A. (2011) · Research on Biomedical Engineering · doi:10.4322/rbeb.2011.002 · Cited by 2
MacDougall, M., & Ingram, J. J. (2016) · Cited by 1
Stadler, R. R., & Soyka, M. (2016) · The Laryngoscope · doi:10.1002/lary.26002 · Cited by 1
ÇOCUK VE GENÇ ATLETLERDE VÜCUT KOMPOZİSYONUNUN DEĞERLENDİRİLMESİ: KARŞILAŞTIRMA ÇALIŞMASI.
Harbili, S., Hazır, T., Aytar, S. H., Şahin, Z., Harbili, E., & Açıkada, C. (2008) · Spor Bilimleri Dergisi · doi:10.17644/sbd.31535 · Cited by 8
Application of T1 scale in evaluating effects of long-term therapy
Kiebzak, W. P., Kosztołowicz, M., Zaborowska-Sapeta, K. A., Kiebzak, M., & Dwornik, M. (2016) · Polish Annals of Medicine · doi:10.1016/j.poamed.2016.03.001 · Cited by 1
Okun, N. B., Tkatch, S., Demianczuk, N. N., Cohen, T., & Mayes, D. C. (2001) · Journal SOGC · doi:10.1016/s0849-5831(16)31319-2 · Cited by 1
Vastus lateralis muscle architecture to estimate knee extension moment of older individuals
Brodt, G. A., Geremia, J. M., Melo, M. D. O., Vaz, M. A., & Loss, J. F. (2015) · Motriz Revista de Educação Física · doi:10.1590/s1980-65742015000400013 · Cited by 1
Transkutane Kohlenstoffdioxidmessung
Bertram, L., Stiel, S., & Grözinger, M. (2012) · Der Anaesthesist · doi:10.1007/s00101-012-2118-x · Cited by 1
Lojo, S., Soto, S., & Lojo-Luaces, N. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1033 · Cited by 1
She, J., Guan, X., Liu, Y., & Xiang, H. (2016) · Journal of Clinical Hypertension · doi:10.1111/jch.12859 · Cited by 1
Alder, B. C., Summers, S. H., & Hare, V. (1997) · Immunohematology · doi:10.21307/immunohematology-2019-713 · Cited by 1
Li, H., Gao, C., Gao, Q., & Yang, Y. (2016) · International Conference on Social Science, Humanities and Modern Education (SSHME) · doi:10.2991/sshme-16.2016.48 · Cited by 1
Laboratory methods in pediatric endocrinology
Chandler, D. W., Chia, D. J., Nakamoto, J. M., Chun, K. Y., Pepkowitz, S. H., & Rapaport, R. (2014) · Elsevier eBooks · doi:10.1016/b978-1-4557-4858-7.00013-5 · Cited by 1
Health-Related Quality of Life Measures in the Information Age
Warrian, K., & Spaeth, G. L. (2009) · IGI Global eBooks · doi:10.4018/978-1-60566-356-2.ch045 · Cited by 1
When visual inspection of the palpebral conjunctivae falls short …
Kamel, H. T., & Vassallo, R. R. (2016) · Transfusion · doi:10.1111/trf.13717 · Cited by 1
Tsuyuki, K., KIMURA, Y., KAMEYAMA, T., Ninomiya, K., Watanabe, S., Choh, K., KOZAKAI, H., & Ebine, K. (2003) · 体力科學 · doi:10.7600/jspfsm1949.52.575 · Cited by 1
Templar, A., Marsh, D., & Nesbeth, D. (2016) · SpringerPlus · doi:10.1186/s40064-016-3074-8 · Cited by 1
Fonteles, A. I., Machado, D. G. D. S., Agrícola, P. M. D., Neto, L. I. N., Moreira, S. R., Elsangedy, H. M., Chao, C. H. N., & Okano, A. H. (2016) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.5007/1980-0037.2016v18n3p287 · Cited by 1
Castro, A., Carvalho, P., Muehlsteff, J., Mattos, S. D. S., & Coimbra, M. T. (2016) · Advances in bioinformatics and biomedical engineering book series · doi:10.4018/978-1-5225-0660-7.ch002 · Cited by 2
The Validity of Image Analysis Freeware in Calculating Physical Angles in Two Dimensions
Yamanaka, Y., MIZUNO, T., Ishikawa, N., SASAKURA, Y., YAMAMOTO, A., & Yoshiki, I. S. H. I. (2016) · Rigakuryoho Kagaku · doi:10.1589/rika.31.571 · Cited by 1
Estimating fat mass in heart failure patients
Trippel, T. D., Lenk, J., Gunga, H., Doehner, W., von Haehling, S., Loncar, G., Edelmann, F., Pieske, B. M., Stahn, A. C., & Duengen, H. (2016) · Archives of Medical Science - Atherosclerotic Diseases · doi:10.5114/amsad.2016.61788 · Cited by 1
Soto, C. M., Allen, R. A., & Decker, S. L. (2016) · Universitas Psychologica · doi:10.11144/javeriana.upsy15-2.aiit
de Antioquia, U., Aristizábal, J. C., Ramírez, S. M. O., de Antioquia, U., Giraldo, A., & de Antioquia, U. (2015) · Perspectivas en Nutrición Humana · doi:10.17533/udea.penh.v17n2a04 · Cited by 3
Stelmach-Mardas, M., Bogdański, P., Mardas, M., Szulińska, M., Walkowiak, J., & Piorunek, T. (2016) · Clinical and Translational Degenerative Diseases · doi:10.4103/2468-5658.191356 · Cited by 1
Luna, J. M., Yip, N. H., Perotte, R., & Vawdrey, D. K. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591250 · Cited by 1
Baig, Z. F., Tareen, T. B., & Ali, A. (2016) · Pakistan Armed Forces Medical Journal · Cited by 1
Optimizing care of ventilated infants by improving weighing accuracy on incubator scales
El-Kafrawy, U., & Taylor, R. (2016) · Journal of Neonatal-Perinatal Medicine · doi:10.3233/npm-161623 · Cited by 1
Non-invasive approach for the assessment of sympathetic baroreflex function: A feasibility study
Paleczny, B., Siennicka, A. E., Ponikowski, P. P., & Ponikowska, B. (2016) · Autonomic Neuroscience · doi:10.1016/j.autneu.2016.12.008 · Cited by 1
Spot urine protein/creatinine ratio is associated with 24-hour proteinuria and serum albumin
Alkan, Ö., Özkök, A., Özportakal, H., Bulut, A. S., İşman, F. K., & Odabaş, A. R. (2016) · Medeniyet Medical Journal · doi:10.5222/mmj.2016.241 · Cited by 1
Clinical trials to compare two treatments
Papageorgiou, S. N. (2017) · Journal of Orthodontics · doi:10.1080/14653125.2017.1279465 · Cited by 1
Paciepnik, J., & Porter, J. A. (2017) · Nutrients · doi:10.3390/nu9020099 · Cited by 1
Silveira, M.-G., Sampol, G., Cambrodí, R., Ferré, À., & Lloberes, P. (2017) · Archivos de Bronconeumología · doi:10.1016/j.arbr.2017.01.001 · Cited by 1
Kabir, M., Sedaghat, G., Thomas, J., & Tereshchenko, L. G. (2016) · PubMed · doi:10.23919/cic.2016.7868736 · Cited by 1
Balleza, M., Vargas, M., Kashina, S., Huerta, M. R., Delgadillo‐Holtfort, I., & Moreno, G. (2017) · Journal of Physics Conference Series · doi:10.1088/1742-6596/792/1/012048 · Cited by 1
Leunkeu, A. N. (2017) · Journal of Novel Physiotherapy and Physical Rehabilitation · doi:10.17352/2455-5487.000045 · Cited by 1
Martins, A., Monjardino, T., Canhão, H. M., & Lucas, R. (2017) · Acta Paediatrica · doi:10.1111/apa.13904 · Cited by 1
Chandnani, S. R., Ramakrishna, C., Dave, B., Kothavade, P. S., & Thakkar, A. S. (2017) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2017/26596.9892 · Cited by 4
Is Ross treadmill method an alternative to Åstrand cycle ergometer method?
Garland, S. W., Ingesson, P., Petersson, H., & Wisén, A. G. M. (2017) · European Journal of Physiotherapy · doi:10.1080/21679169.2017.1340515 · Cited by 1
Al-Busaidi, A. A., Jeyaseelan, L., & Al-Barwani, H. M. (2017) · Sultan Qaboos University medical journal · doi:10.18295/squmj.2016.17.02.009 · Cited by 1
Kirkegaard-Nielsen, H., Helbo-Hansen, H. S., Severinsen, I. K., Lindholm, P., & Bülow, K. (1996) · International journal of clinical monitoring and computing · doi:10.1023/a:1016929721934 · Cited by 1
R, J. S. K., Jayakumar, C., Anupama Pillai, S., & José, O. (2017) · Journal of Evolution of Medical and Dental Sciences · doi:10.14260/jemds/2017/620 · Cited by 1
EFEITO AGUDO DE DIFERENTES MÉTODOS DE ALONGAMENTO SOBRE O DESEMPENHO DA FORÇA EM SÉRIES SUCESSIVAS
de Souza, D. V. B. C., Santana, A. C., Meireles, K. B., & César, E. P. (2017) · journal of physical education · doi:10.4025/jphyseduc.v28i1.2832 · Cited by 6
A Novel Evaluation for Predicting Aortic Complicated Lesions Using Calcification on Chest X-ray
Yamaguchi, Y., Tanaka, T., Yoshimura, S., Koga, M., Nagatsuka, K., & Toyoda, Ḱ. (2017) · Cerebrovascular Diseases · doi:10.1159/000479117 · Cited by 2
Evaluation of ADAMS ™ A1C Menarini HA-8180 HPLC Analyzer for HbA1C Determination
Urrechaga, E. (2012) · Cited by 1
Tompuri, T., Lintu, N., Laitinen, T. T., & Lakka, T. A. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12461 · Cited by 1
Interaction Of Stocking Density And The Feeding Environment In Lactating Holstein Dairy Cows
Campbell, M. A. (2017) · ScholarWorks -A service of University of Vermont Libraries (University of Vermont) · Cited by 1
How to Report Exotic Animal Research
Girolamo, N. D., & Winter, A. L. (2017) · Veterinary Clinics of North America Exotic Animal Practice · doi:10.1016/j.cvex.2017.04.010 · Cited by 1
Statistics in Nuclear Cardiology
Williams, D. N., Harrild, D. M., Williams, K., & Monuteaux, M. C. (2017) · Annals of Nuclear Cardiology · doi:10.17996/anc.17-00030 · Cited by 1
Syarif, A. N., & Bangun, K. (2017) · Journal of Physics Conference Series · doi:10.1088/1742-6596/884/1/012066 · Cited by 1
An in vitro lung model to assess true shunt fraction by multiple inert gas elimination
Varadarajan, B., Vogt, A. P., Hartwich, V., Vasireddy, R., Consiglio, J., Hugi‐Mayr, B., & Eberle, B. (2017) · PLoS ONE · doi:10.1371/journal.pone.0184212 · Cited by 1
Postema, S. G., Bongers, R. M., van der Sluis, C. K., & Reneman, M. F. (2017) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-017-9723-0 · Cited by 1
Lee, X. W., Marshall, H., Leong, S. C., O’Rourke, R., Steinke, K., Mirjalili, N., Bowman, R., Yang, I. A., & Fong, K. M. (2017) · Journal of Thoracic Imaging · doi:10.1097/rti.0000000000000298 · Cited by 1
Jacob, Z., Fan, R., Reinsel, R. A., Patel, N., & Chandrakantan, A. (2017) · Open Journal of Anesthesiology · doi:10.4236/ojanes.2017.79031 · Cited by 1
Gehrich, A. P., Patzwald, J. R., Raby, L., Lustik, M. B., Gruber, D. D., & Gonzalez, H. (2017) · Military Medicine · doi:10.7205/milmed-d-17-00140 · Cited by 1
Physical activity measurement accuracy in advanced chronic lung disease
Dhillon, S. S., Levy, R. D., Wilcox, P., Guenette, J. A., Quon, B. S., Ryerson, C. J., & Camp, P. G. (2017) · Canadian Journal of Respiratory Critical Care and Sleep Medicine · doi:10.1080/24745332.2017.1393636 · Cited by 1
Dolmage, T. E., Evans, R. A., & Goldstein, R. S. (2017) · CHEST Journal · doi:10.1016/j.chest.2017.11.024 · Cited by 1
Statistical Evidence in Medical Trials: What Do the Data Really Tell Us
Hamilton, C. (2006) · Baylor University Medical Center Proceedings · doi:10.1080/08998280.2006.11928213 · Cited by 1
Aldossary, M. S., Santini, A., & Alayan, I. A. (2017) · International Journal of Forensic Odontology · doi:10.4103/ijfo.ijfo_11_17 · Cited by 2
Özkan, M. B., Bilgici, M. N. C., Eren, E., & Çaltepe, G. (2018) · Iranian Journal of Radiology · doi:10.5812/iranjradiol.14267 · Cited by 1
Paglialunga, S., Morimoto, B. H., de la Peña, A., & Fortier, C. (2018) · Clinical Pharmacology in Drug Development · doi:10.1002/cpdd.437 · Cited by 2
Freehand 3D Ultrasound to Measure Thrombus Volume in Patients with Acute Deep-Vein Thrombosis
Zhao, L., Kampmann, M., Prior, S. J., Sorkin, M. J., Braganza, M., McEvoy, S., & Lal, B. K. (2014) · Journal for Vascular Ultrasound · doi:10.1177/154431671403800104 · Cited by 1
Human evaluation in association to the mathematical analysis of arch forms: Two-dimensional study
Zabidin, N., Mohamed, A. M. F. S., Zaharim, A., Nor, M. M., & Rosli, T. I. (2018) · International Orthodontics · doi:10.1016/j.ortho.2018.01.009 · Cited by 1
Sperm concentration measurement with a disposable counting chamber
Patrat, C., Lemoine, M., Ferraretto, X., Royer, M.-A.-D., Benammar, A., Darolles, J., Epelboin, S., & Eustache, F. (2018) · Asian Journal of Andrology · doi:10.4103/aja.aja_72_17 · Cited by 2
Inter-rater agreement of the Turkish version of the Neurobehavioral Rating Scale-Revised form
Çakçı, A., Meray, J., Örsel, S., Alaca, R., Çulha, C., Gündoğdu, İ., Yaşar, E., Öztuna, D., Gürcay, E., Umay, E., et al. (2017) · Turkish Journal of Physical Medicine and Rehabilitation · doi:10.5606/tftrd.2017.207 · Cited by 1
Ripley, E. M., Clarke, G. D., Deng, S., Tripathy, D., DeFronzo, R. A., & Vasquez, J. A. (2018) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2294627 · Cited by 1
Adhemir Valera, A., Jessica Jurado, P., Alberto Manchego, S., & Nieves Sandoval, C. (2018) · Revista de Investigaciones Veterinarias del Perú · doi:10.15381/rivep.v29i1.14080 · Cited by 1
Masoud, M., Kengne, A. P., Erasmus, R. T., Hon, G. M., Macharia, M., & Matsha, T. E. (2018) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-018-0748-8 · Cited by 2
Gómez‐Campos, R., Carrillo, J. P., Fierro, A. A., Urra-Albornoz, C., & Cossio‐Bolaños, M. (2018) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2017.11.008 · Cited by 1
Tavares, B. M., Klein, C. H., & Bloch, K. V. (2017) · Revista Brasileira de Saúde Materno Infantil · doi:10.1590/1806-93042017000400006 · Cited by 1
Capone, D., Cataldi, M., Guida, B., Mosca, T., & Tarantino, G. (2018) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2018.1455131 · Cited by 1
Amin, M. I., Hassan, H. A., & Mousa, M. I. A. A. E. A. (2018) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1016/j.ejrnm.2017.10.008 · Cited by 1
Chiang, H.-Y. A., Lu, W.-S., Yu, W.-H., Hsueh, I., & Hsieh, C. (2018) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2018.03.011 · Cited by 1
Influence of body position on the measurement of electrocardiographic waves in healthy dogs
Sousa, M. G., Rondelli, M. C. H., Nogueira, S. S. D. S., & Carareto, R. (2018) · Pesquisa Veterinária Brasileira · doi:10.1590/1678-5150-pvb-5071 · Cited by 1
Sirinukunwattana, K., Lin, J., Lu, P., de Beça, F. F., Peng, J., Tolwani, A., Stancu, A. L., Varma, S., & West, R. B. (2018) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2018.8363551 · Cited by 1
The hip control test is a valid and reliable measure of hip neuromuscular control
Brindle, R. A., & Milner, C. E. (2018) · Sports Biomechanics · doi:10.1080/14763141.2018.1466907 · Cited by 1
Zhang, Y., Wang, L., Yin, C., Mu, K., Niu, D., & Yan, W. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-019645 · Cited by 1
Feniman, S. P., Cardoso, J. R., Villegas, I. L. P., Bela, L. F. D., Santos, S. M. S., & Lavado, E. L. (2016) · Acta Fisiátrica · doi:10.5935/0104-7795.20160033 · Cited by 1
Black, A. C., McMahon, T. J., Brecht, M., & Rosen, M. I. (2018) · Military Psychology · doi:10.1080/08995605.2018.1478560 · Cited by 1
Shouji, Y., Hasegawa, C., Lee, X., Fujishiro, M., Matsuyama, T., Yamada, M., Kuriki, A., Kato, Y., Nemoto, N., Kumazawa, T., et al. (2018) · The Showa University Journal of Medical Sciences · doi:10.15369/sujms.30.175 · Cited by 1
Ctori, I., Mahroo, O. A., Williams, K. M., Hammond, C. J., & Huntjens, B. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13725 · Cited by 1
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.