STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 43,001–43,100 of 47,868
Savini, G., Hoffer, K. J., Schiano‐Lomoriello, D., & Ducoli, P. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.12.030 · Cited by 1
Clinical approach to gastro-oesophageal reflux in idiopathic pulmonary fibrosis
Jones, R. (2016) · Cited by 1
Gangell, C. L. (2008) · UWA Profiles and Research Repository (University of Western Australia) · Cited by 1
Reliability and Validity of a Prototype Fluid Intake Monitor
Tharion, W. J., Karis, A. J., & Hoyt, R. W. (2009) · Defense Technical Information Center (DTIC) · doi:10.21236/ada492057 · Cited by 1
Western, M. J. (2016) · The University of Bath Online Publications Store (The University of Bath) · Cited by 1
Dougados, M., Maheu, E., Cadet, C., Gueneugues, S., & Ravaud, P. (2007) · Cited by 1
Luca, M. C. (2012) · Library and Archives Canada (Government of Canada) · Cited by 2
Force measuring device applied in cardiopulmonary resuscitation
Šantić, A., Kovačić, D., & Gilly, H. (2001) · Cited by 1
A new method for the non-invasive measurement of cardiac output during spontaneous ventilation
Preiss, D. A. (2005) · TSpace (University of Toronto) · Cited by 1
Evaluation of a Method for Measuring Minute Volumes during Bias-Flow Ventilation
Torres, A., Yeh, M. P., Wilson, S., Anders, M., & Heulitt, M. J. (1995) · Respiratory Care · doi:10.1177/194336549504000105 · Cited by 1
Morrow, J. M. (2017) · UCL Discovery (University College London) · Cited by 1
Hypoxic exposure to optimise altitude training adaptations in elite endurance athletes
Turner, G. (2016) · Cited by 2
Tanaka, K. (2016) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/27073 · Cited by 2
Effect of abdominal aortic aneurysm screening
Frønsdal, K. B., Sæterdal, I., Harboe, I., Klemp, M., & Fure, B. (2014) · NORA - Norwegian Open Research Archives · Cited by 1
Compositional Correlation for Detecting Real Associations Among Time SeriesPreprint
Dikbaş, F. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1801.05029 · Cited by 1
The relationship between diet and tear analysis in routine optometric practice
Janjua, S. (2017) · Aston Publications Explorer (Aston University) · doi:10.48780/publications.aston.ac.uk.00032213 · Cited by 1
Olowoyeye, O. A. (2017) · TSpace (University of Toronto) · Cited by 1
Rehani, M. T. R. (2013) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r32t48 · Cited by 1
Body composition in very preterm infants during their hospital stay
Al-Theyab, N. S. (2018) · The University of Queensland · doi:10.14264/uql.2018.177 · Cited by 1
Het afnemen van de Van Wiechenkenmerken door ouders
Grevinga, M., van Harten, L., Hofstetter, H., Verkerk, P. H., & Detmar, S. B. (2018) · JGZ Tijdschrift voor jeugdgezondheidszorg · doi:10.1007/s12452-018-0140-3 · Cited by 1
Xu, D. R. (2017) · ResearchWorks at the University of Washington (University of Washington) · Cited by 2
The clinical skills of optometrists in assessing the anterior chamber angle
Campbell, P. (2014) · Cited by 1
Targeted use of technology to assist with fall risk classification in older adults
Commandeur, D. T. (2018) · UVic’s Research and Learning Repository (University of Victoria) · Cited by 1
Prediction of Heat Strain by Heart Rate for Firefighters in Protective Clothing
김시연 (2018) · Seoul National University Open Repository (Seoul National University) · Cited by 3
Maeger, K. (2018) · VTechWorks (Virginia Tech) · Cited by 2
Computerized modeling of outcomes and lens fitting in orthokeratology
Mountford, J. (2004) · Elsevier eBooks · doi:10.1016/b978-0-7506-4007-7.50010-6 · Cited by 1
Assessment Battery for Communication
Sacco, K., Angeleri, R., Bosco, F. M., Colle, L., Mate, D., & Bara, B. G. (2008) · PsycTESTS Dataset · doi:10.1037/t39743-000 · Cited by 1
Proceedings of the Workshop on Task-Focused Summarization and Question Answering
Chua, T., Goldstein, J., Teufel, S., & Vanderwende, L. (2006) · Cited by 1
Shirley, D. G., Macrae, K. D., & Vincent, H. H. (1988) · The Lancet · doi:10.1016/s0140-6736(88)91433-x · Cited by 1
Plastic optical fibre based sensors for monitoring physiological parameters in clinical environments
Kam, W. (2018) · University of Limerick Institutional Repository (University of Limerick) · doi:10.34961/3798 · Cited by 1
Applied performance analysis in canoe slalom
Wells, J. (2018) · Middlesex University Research Repository (Middlesex University Of London) · Cited by 1
Bartolucci, A. A., Singh, K. P., & Bae, S. (2015) · Wiley eBooks · doi:10.1002/9781118736890.ch3 · Cited by 1
Year in review 2006: Critical Care – cardiology
Al-Subaie, N., & BENNETT, D. B. (2007) · Critical Care · doi:10.1186/cc5978 · Cited by 1
de Munck, F. (2019) · Utrecht University Repository (Utrecht University) · Cited by 1
On measuring “agreement” and not “correlation”
Vasan, R. S. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90038-o · Cited by 1
Visual acuity in normal and diseased eyes using high-pass filtered optotypes
Shah, N. (2018) · UCL Discovery (University College London) · Cited by 1
Etyang, A. O. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2019.1224 · Cited by 1
Jones, C. M. (2018) · Cronfa (Swansea University) · doi:10.23889/suthesis.49018 · Cited by 1
Improving Recording and Interpretation of Fossil Tracks
Wiseman, A. L. A. (2021) · Liverpool John Moores University · doi:10.24377/ljmu.t.00010970 · Cited by 1
How Well Does the Neonatal Heart Measure Up?
Lopez, L., & Colan, S. D. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.04.423 · Cited by 1
Functional outcome of the upper limb after stroke
Blake, P., & Fritz, V. U. (1996) · South African Journal of Physiotherapy · doi:10.4102/sajp.v52i2.635 · Cited by 1
WITHDRAWNPreprint
Delahunty, F., Arčan, M., & Johansson, R. (2019) · Thesis Commons (OSF Preprints) · doi:10.31237/osf.io/98c3q · Cited by 1
Dos’Santos, T., Lake, J. P., & Comfort, P. (2019) · Sports Biomechanics · doi:10.1080/14763141.2019.1666911 · Cited by 1
Pending Right Heart Failure in Healthy Preterm-Born Subjects?
Tello, K., Richter, M. J., & Naeije, R. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201911-2188le · Cited by 1
Numerical Interpretation of Physiological Variables
Bland, J. M. (2020) · Wiley eBooks · doi:10.1002/9781118597309.ch5 · Cited by 1
Validation of the Instant Blood Pressure App
Plante, T. B. (2016) · Cited by 1
Green, R. W. (2020) · Figshare · Cited by 1
Estimating Systematic Error of Measurement Procedures of Lipid Quantities.
García-Panyella, M., García‐Santamarina, S., & Fuentes‐Arderiu, X. (2006) · Europe PMC (PubMed Central) · Cited by 1
Kulnik, S. T. (2020) · Dysphagia · doi:10.1007/s00455-020-10134-x · Cited by 1
Magnetic-resonance pelvimetry in breech presentation
van Loon, A., & Mantingh, A. (1998) · The Lancet · doi:10.1016/s0140-6736(05)70334-2 · Cited by 1
McDonough, P. G. (2000) · Fertility and Sterility · doi:10.1016/s0015-0282(99)00432-x · Cited by 1
O'keefe, J. (2020) · Liverpool John Moores University · Cited by 2
Babačić, H., Lehtiö, J., & Pernemalm, M. (2020) · medRxiv · doi:10.1101/2020.05.28.20114934 · Cited by 2
Ooi, P. H. (2020) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3-ws2v-1r38 · Cited by 1
Wan, K. H.-N., & Kua, W. N. (2020) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2020.05.044 · Cited by 1
Mean Arterial Pressure in Acute Ischemic Stroke Study
Grove, M. (2020) · doi:10.21007/etd.cghs.2020.0511 · Cited by 1
How to write a manuscript for Sports Engineering
Allen, T., Blocken, B. J. E., Drory, A., & Espinosa, H. G. (2020) · Sports Engineering · doi:10.1007/s12283-020-00335-w · Cited by 1
Development and applications of a smartphone-based mobile electroencephalography (EEG) system
Bateson, A. D. (2018) · Repository@Hull (Worktribe) (University of Hull) · Cited by 1
Difference in hoof conformation between shod and barefoot-managed hoovesPreprint
de Klerk, J. N. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.02.23.432452 · Cited by 1
Helter, T. M., Coast, J., Łaszewska, A., Stamm, T., & Simon, J. (2020) · Research Square · doi:10.21203/rs.3.rs-44326/v1 · Cited by 1
Forrer, F., Rolleman, E. J., Schramm, N. U., Krenning, E. P., & de Jong, M. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0445-y · Cited by 1
Direct and CBCT dentogingival tissue thickness measurements
Müller, H. (2015) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2014.11.019 · Cited by 1
High-fidelity Cuff to Measure Blood Pressure: Comment
Dueck, M. H. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003818 · Cited by 1
McDonald, E. J. (2021) · UWSpace (University of Waterloo) · Cited by 2
Outcome Measures in Clinical Trials
Heyse, J. F. (2005) · Wiley eBooks · doi:10.1002/0470011815.b2a01042 · Cited by 1
Changes in Pharyngeal Airway Dimensions Due to MARA Treatment in Class II Malocclusions
Dillehay, J. (2013) · doi:10.21007/etd.cghs.2013.0071 · Cited by 1
An Accuracy of Finger Pulse Oximeter ONYX^<TM> in Postoperative
芹田, 良., 森崎, 浩., 島田, 宗., 落合, 亮., 武田, 純., & 福島, 和. (1997) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/ikakikaigaku.67.1_26 · Cited by 1
Accuracy, Precision, And Agreement Statistical Tests For Bland-Altman MethodPreprint
Silveira, P. S. P., Vieira, J. E., Ferraro, A., & Siqueira, J. D. O. (2021) · Research Square · doi:10.21203/rs.3.rs-1074884/v1 · Cited by 1
Xu, Q., Wang, K., Li, Y., Qu, J., & Zhao, M. (2021) · Research Square · doi:10.21203/rs.3.rs-535008/v1 · Cited by 1
Matsubayashi, J. (2021) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543406.2021.1968894 · Cited by 1
A multi-factorial evaluation of lower back injury risk factors in fast bowlers.
Barry, T. J. (2026) · e-space (Manchester Metropolitan University) · doi:10.83056/mmu.32478234 · Cited by 2
Besler, B. A., Kemp, T. D., Forkert, N. D., & Boyd, S. K. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2111.01350 · Cited by 1
Balshaw, T. G. (2013) · Stirling Online Research Repository (University of Stirling) · Cited by 5
Multimodality imaging of anatomy and function in coronary artery disease
Schuijf, J. D. (2003) · Leiden Repository (Leiden University) · Cited by 1
Radner, W., Stifter, E., Richter‐Mueksch, S., Kiss, C., & Velikay‐Parel, M. (2004) · Springer eBooks · doi:10.1007/978-3-7091-7985-7_31 · Cited by 1
Desarrollo de una aplicación para dispositivos móviles para el estudio de hábitos de vida saludables
Miranda, V., & Heigueer, H. (2012) · RECERCAT (Consorci de Serveis Universitaris de Catalunya) · Cited by 1
zhang, H., Guo, Y., liu, H., tang, H., li, Y., & zhang, L. (2020) · Research Square · doi:10.21203/rs.3.rs-122489/v1 · Cited by 1
Calibration allows accurate estimation of the axonal volume fraction with diffusion MRIPreprint
Papazoglou, S., Ashtarayeh, M., Oeschger, J. M., Callaghan, M. F., Does, M. D., & Mohammadi, S. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.04.12.488014 · Cited by 1
Serrano‐Gallardo, P., Gavín, M. O., Rodríguez, S. F., & Ayçaguer, L. C. S. (2003) · Medicina Clínica · doi:10.1016/s0025-7753(03)74100-1 · Cited by 1
Dawson, J. (2014) · Springer eBooks · doi:10.1007/978-94-007-0753-5_2048 · Cited by 1
Bellamy, N. (1993) · Springer eBooks · doi:10.1007/978-94-011-2218-4_6 · Cited by 1
(1987) · Journal of the Royal Statistical Society Series C (Applied Statistics) · doi:10.1111/j.1467-9876.1987.tb02011.x · Cited by 1
Ferguson, J. J. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00445-v · Cited by 1
Liao, J. J. Z., & Capen, R. C. (2008) · Wiley eBooks · doi:10.1002/9780471462422.eoct303 · Cited by 1
Yeo, G., & Chang, T. C. (1995) · Fetal and Maternal Medicine Review · doi:10.1017/s0965539500001352 · Cited by 1
Alterman, R. L., Fleishman, A., & Ngo, L. H. (2018) · Operative Neurosurgery · doi:10.1093/ons/opy139 · Cited by 1
Pingel, J., Harrison, A. P., Suetta, C., Rørdam, L., Bülow, J., & Langberg, H. (2012) · Scandinavian Journal of Rheumatology · doi:10.3109/03009742.2012.725576 · Cited by 1
(1995) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1995.33.8.525 · Cited by 1
Szaflarski, N. L. (2004) · American Journal of Critical Care · doi:10.4037/ajcc2004.13.2.100 · Cited by 1
Schwenke, C. (2014) · Wiley eBooks · doi:10.1002/9781118445112.stat06838 · Cited by 1
4. Monitoring proteinuria in patients with suspected or known renal disease
(2004) · Nephrology · doi:10.1111/j.1440-1797.2004.00314.x · Cited by 1
O’Meara, S. (2008) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2007.02108.x · Cited by 1
Wolk, D. M., & Marlowe, E. M. (2011) · Molecular Microbiology · doi:10.1128/9781555816834.ch55 · Cited by 1
Kaussen, T., Gutting, M., Lasch, F., Boethig, D., von Gise, A., Dingemann, J., Köditz, H., Jack, T., Sasse, M., Beerbaum, P., et al. (2020) · Research Square · doi:10.21203/rs.3.rs-124366/v1 · Cited by 1
(1995) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1995.33.9.609 · Cited by 1
(1996) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329603300521 · Cited by 1
Horváth, C., Fisser, C., Bradley, T. D., Floras, J. S., Sossalla, S. T., Parati, G., Zeman, F., Castiglioni, P., Faini, A., Rankin, F., et al. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4105039 · Cited by 1
Takakura, M., Fujii, T., Taniguchi, T., Suzuki, S., & Nishiwaki, K. (2022) · Research Square · doi:10.21203/rs.3.rs-2174850/v1 · Cited by 1
Zhang, J., Chaudhari, G., Bonderenko, M., & Sohn, J. H. (2022) · medRxiv · doi:10.1101/2022.10.31.22281562 · Cited by 1
The Pupil Grating Response and Visual Acuity
Cocker, K. D., & Moseley, M. J. (1991) · Noninvasive Assessment of the Visual System · doi:10.1364/navs.1991.md16 · Cited by 1
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.