STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 42,701–42,800 of 47,868
In vitro and in vivo feasibility study of ultrasound for monitoring tooth surface loss
Sindi, K. H. (2013) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 1
Karlsson, C. E. (2015) · University Library of Skövde (University of Skövde) · Cited by 3
Psychological screening of temporomandibular disorder patients
van der Meulen, M. J. (2011) · UvA-DARE (University of Amsterdam) · Cited by 1
USING TECHNOLOGY TO CHANGE ADULT SEDENTARY BEHAVIOUR, PHYSICAL ACTIVITY LEVELS AND TOTAL WELLNESS
Barwais, F. A. (2013) · doi:10.13140/rg.2.2.35623.75681 · Cited by 1
Alternative Lead Systems for Diagnostic Electrocardiography: Validation and Clinical Applicability
Welinder, A. (2009) · Lund University Publications (Lund University) · Cited by 1
Changes in anthropometry, somatotype and body composition during puberty: a longitudinal study
Leppik, A. (2005) · DSpace repository (University of Tartu) · Cited by 28
Towards an understanding of physical activity in people with chronic low back pain
Griffin, D. W. (2013) · University of Limerick · doi:10.34961/7893 · Cited by 1
Myocardial flow reserve: On-line versus off-line assessment techniques
Linden, M. M. J. M. V. D., Haase, J., & Serruys, P. W. J. C. (1994) · Developments in cardiovascular medicine · doi:10.1007/978-94-011-1172-0_11 · Cited by 1
Métodos para quantificação da artéria carótida em imagens de ultrassom modo-B e Doppler.
Higa, M. (2009) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.3.2009.tde-11082010-163813 · Cited by 4
McHugh, M. P. (1999) · Bangor University Research Portal (Bangor University) · Cited by 2
Quality of functional capacity evaluation tests : a clinimetric approach
Gouttebarge, V. (2008) · UvA-DARE (University of Amsterdam) · Cited by 2
Individual differences in excitation and inhibition in visual cortex
Robson, S. E. (2012) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1
THE VALIDATION OF AN ARTIFICIAL NEURAL NETWORK TO PREDICT POWER OUTPUT FROM ROWING KINEMATICS
O’Halloran, J., & Anderson, R. E. (2007) · ISBS - Conference Proceedings Archive · Cited by 1
New insights into respiratory muscle function in an athletic population
Kroff, J. (2008) · SUNScholar (Stellenbosch University) · Cited by 1
Desebbe, O., Joosten, A., & Suehiro, K. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001130 · Cited by 1
MANA, F., Ham, H. R., Franken, P. R., GEORGES, B., & Urbain, D. (2002) · Nuclear Medicine Communications · doi:10.1097/00006231-200202000-00010 · Cited by 1
Intravascular Ultrasound: Technique, Measurements and Angioplasty Guidance
Gaster, A. L., & Thayssen, P. (2002) · Heart Drug · doi:10.1159/000053055 · Cited by 1
Accuracy of cardiac PET imaging using post-injection transmission scan
Yoneyama, T., Matsunari, I., 金山, 寿., Matsudaira, M., Nakajima, K., Taki, J., Nekolla, S. G., Hisada, K., & Tonami, N. (2005) · Annals of Nuclear Medicine · doi:10.1007/bf03027385 · Cited by 1
Wessel, A., Buchhorn, R., Löber, M., Eigster, G., Hulpke‐Wette, M., & Bürsch, J. H. (1999) · Zeitschrift für Kardiologie · doi:10.1007/s003920050355 · Cited by 1
Silosky, M. S. (2012) · Digital Commons-TMC (Texas Medical Center) · Cited by 1
Zhe, X., Tian, X.-K., Shan, Y.-S., Cheng, L., & Wang, T. (2007) · Nephron Clinical Practice · doi:10.1159/000110031 · Cited by 1
Repeatability of laser Doppler measurements of cutaneous blood flow in clinical pharmacology studies
Maison, P., Démolis, P., & Giudicelli, J. (1996) · Fundamental and Clinical Pharmacology · doi:10.1111/j.1472-8206.1996.tb00313.x · Cited by 1
Arbutamine stimulation detects viable myocardium 4 weeks after coronary occlusion
Kisanuki, A., Segar, D. S., Ryan, T., Johnson, M., Tei, C., Feigenbaum, H., & Sawada, S. G. (2001) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.108932 · Cited by 1
Stenehjem, A., & Os, I. (2006) · Blood Pressure · doi:10.1080/08037050600996628 · Cited by 1
Thin, A. G., Kelly, G., Daly, L., & McLoughlin, P. (2004) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2004.06.004 · Cited by 1
Monitoring of Lung Edema by Microwave Reflectometry during Lung Ischemia-Reperfusion Injury in vivo
Nowak, K., Schaefer, M., Groß, W., Metzger, R. P., Hohenberger, P., Post, S., & Gebhard, M. M. (2006) · European Surgical Research · doi:10.1159/000091481 · Cited by 1
Evaluation of the pinhole pupillometer
German, E. J., Hurst, M., & Wood, D. (1998) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(98)00034-9 · Cited by 1
Ollier, F., Duché, P., & Vermorel, M. (2006) · Cahiers de Nutrition et de Diététique · doi:10.1016/s0007-9960(06)70604-6 · Cited by 1
Accurate and Precise Blood Glucose Measurement in the Hypoglycaemic Range
Tieszen, K. L., Patrick, A. W., Smith, E., Williams, G., & Dornan, T. (1993) · Diabetic Medicine · doi:10.1111/j.1464-5491.1993.tb00121.x · Cited by 1
Recognition of Cognitive Impairment in Elderly Patients Being Discharged from Hospital
Mulkerrin, E. C., Nicklason, F., Sykes, D., Dewar, R., Bayer, A. J., & Finucane, P. M. (1993) · Clinical Gerontologist · doi:10.1300/j018v12n01_02 · Cited by 1
Comparison of a new brain tissue oxygenation measuring probe with the established standard
Wolf, S., Schürer, L., Horn, P., & Lumenta, C. B. (2009) · Critical Care · doi:10.1186/cc7254 · Cited by 1
Skeletal maturity in normal children from Liverpool, United Kingdom
Dhar, S., & Dangerfield, P. (1992) · Clinical Anatomy · doi:10.1002/ca.980050606 · Cited by 1
Emilsson, K., Loiske, K., & Öhlin, B. (2005) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2005.00610.x · Cited by 1
Use of Misleading Statistics in Method Comparison Analyses
Martínez‐Pastor, F. (2010) · Journal of Andrology · doi:10.2164/jandrol.109.009704 · Cited by 1
Júnior, J. O. C. A., Kim, S. M., Carmona, M. J. C., Malbouisson, L. M. S., & de Oliveira, S. A. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021506211372 · Cited by 1
Vincze, G., & Parthan, A. (2004) · Journal of Pharmacy Practice · doi:10.1177/0897190004264815 · Cited by 1
Ventricular systolic discordance in pericardial tamponade: acute reversal by pericardiocentesis
Kim, A. M., & Fifer, M. A. (2006) · Heart · doi:10.1136/hrt.2005.077180 · Cited by 1
Claessens, T. E., Verwilst, P., Missant, C., Claus, P., Verdonck, P., Wouters, P. F., & Segers, P. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.08.010 · Cited by 1
Evaluation of Wright pocket flow meter with mini Wright meter in children and adults
Frankland, A. W., Atkinson, B., Morris, R. W., & Davison, J. R. (1993) · Respiratory Medicine · doi:10.1016/0954-6111(93)90012-o · Cited by 1
The use of variance components for the assessment of outcome measures in rheumatology
Allen, E., & Farewell, V. T. (2010) · Journal of Applied Statistics · doi:10.1080/02664760903301135 · Cited by 1
Assessment of the Glycotronic C blood glucose meter.
Forrest, A. R. W., & Pitt, E. J. (1991) · Journal of Clinical Pathology · doi:10.1136/jcp.44.9.785 · Cited by 1
César, K. R., Bueno, C. T., & Rabelo, R. (2003) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/00134384-200306000-00004 · Cited by 1
The Effect of Preload Reduction on a New Parameter to Evaluate Left Ventricular Diastolic Function
Yoo, S. Y., Choi, E. A., Ahn, S. G., Choi, J. H., Woo, S. I., Choi, S. Y., Yoon, M., Hwang, G., Tahk, S. J., Kim, H., et al. (2005) · Korean Circulation Journal · doi:10.4070/kcj.2005.35.11.827 · Cited by 1
Virtanen, V., & Groundstroem, K. (1998) · Echocardiography · doi:10.1111/j.1540-8175.1998.tb00658.x · Cited by 1
Rieke, H., Weyland, A., Wayland, W., Hoeft, A., & Sonntag, H. (1989) · Journal of Cardiothoracic Anesthesia · doi:10.1016/0888-6296(89)90762-x · Cited by 1
García‐Lledó, A., Mur, J. L. M., Recena, J. B., García, E. N., Gorospe, C. C., Jorge, P., Barea, R., & Boquete, L. (1998) · Revista Española de Cardiología · doi:10.1016/s0300-8932(98)74805-5 · Cited by 1
Pulmonary arterial hypertension
Miniati, M. (2009) · Internal and Emergency Medicine · doi:10.1007/s11739-009-0321-9 · Cited by 1
Herbst, T., Anwar, Y. A., Giacco, S., & White, W. B. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200210000-00007 · Cited by 1
How to interpret the eGFR in patients with small body surface area
Park, E.-Y., & Kim, T. (2009) · Kidney International · doi:10.1038/ki.2009.362 · Cited by 1
Sharp, D. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16955-9 · Cited by 1
Clinical Usefulness of Intravenous Albunex for the Doppler Assessment of Aortic Stenosis
Iwase, M., Koie, S., Nagasaka, A., Kimura, M., Hasegawa, K., Matsuyama, H., Nomura, M., & Hishida, H. (2000) · Japanese Circulation Journal-english Edition · doi:10.1253/jcj.64.672 · Cited by 1
Intraocular Pressure Measurement Over Amniotic Membrane Patch in Human Subjects
Hashizume, A., Usui, T., Yokoo, S., Mimura, T., Araie, M., Yamagami, S., & Amano, S. (2005) · Cornea · doi:10.1097/01.ico.0000160968.73577.ml · Cited by 1
Høiseth, A. D. (1999) · Acta Radiologica · doi:10.3109/02841859909175585 · Cited by 1
Direct measurement of glomerular filtration rate
(2005) · Nephrology · doi:10.1111/j.1440-1797.2005.00487_4.x · Cited by 1
Manual and semi-automatic registration vs retrospective ECG gating for correction of cardiac motion
So, A., Adam, V., Acharya, K., Pan, T.-S., & Lee, T.-Y. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.480398 · Cited by 1
Jagadamma, K. C. (2010) · Queen Margaret University eTheses Repository · Cited by 1
STATISTICAL RIGOUR IS ESSENTIAL TO CLINICAL PREDICTION
Gebski, V., Byth, K., & Langlands, A. O. (2007) · ANZ Journal of Surgery · doi:10.1111/j.1445-2197.2007.04164.x · Cited by 1
Smits, P. C., Pasterkamp, G., Eefting, F. D., Stella, P. R., de Jaegere, P. P. T., & Borst, C. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00009-5 · Cited by 1
Quantitation of solid-phase immunoassays using a fibre-optic reflectance spectrophotometer
McCarthy, D. A., Rehman, A., Batchelder, D. N., Bubel, M., & Bainbridge, D. (1991) · Journal of Immunological Methods · doi:10.1016/0022-1759(91)90042-e · Cited by 1
Kayser, J. P., Hoffman, R. M., Haffner, J. C., & Johansson, H. (2011) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2011.03.050 · Cited by 1
Evaluation of the tracking potential of a noninvasive estimator of cardiac output
Redling, J. D., & Akay, M. (1996) · Computers in Biology and Medicine · doi:10.1016/0010-4825(96)00008-x · Cited by 1
P063 The repeatability of observational gait analysis in clinical lower limb prosthetics
Hillman, S. J., McCurrach, E., Richardson, A., Herman, J., McGarry, A., & Robb, J. (2008) · Gait & Posture · doi:10.1016/s0966-6362(08)70132-2 · Cited by 1
Kumae, T. (2001) · Nutrition Research · doi:10.1016/s0271-5317(01)00264-0 · Cited by 1
Estimation of mitral valve area from regression analysis of the pressure gradient in mitral stenosis
Bittl, J. A., Yeung, A. C., Vekshtein, V. I., Parker, J. D., & Fish, R. D. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90862-s · Cited by 1
Evaluation of a new combined CO 2 and respiratory monitoring system
Rockmann, F., Langgartner, J., Girlich, C., Schölmerich, J., & Reng, M. (2004) · Clinical Intensive Care · doi:10.1080/09563070400005438 · Cited by 1
Assessing the Rate of Bone Loss: A Technique Revisited
REEVE, J., & Lunt, M. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.11.1990 · Cited by 1
Monitorización no invasiva de la PaCO2 en pacientes críticos con ventilación mecánica
Fernandez, J., Impuesto, V. C., & Lendínez, M. J. (2000) · Medicina Intensiva · doi:10.1016/s0210-5691(00)79608-2 · Cited by 2
Seppälä, O.-P. (1994) · Respiratory Medicine · doi:10.1016/0954-6111(94)90056-6 · Cited by 1
A critique on measuring reliability in exercise tests and outcome measures
Buckley, J. P. (2012) · European Journal of Preventive Cardiology · doi:10.1177/1741826711429780 · Cited by 1
Accurate measurement of albuminuria at reduced cost
Krimholtz, M., Smith, A., & Viberti, G. C. (2004) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfh200 · Cited by 1
Kyriacou, P. A., Pal, S. K., Langford, R. M., & Jones, D. P. (2006) · Measurement and Control · doi:10.1177/002029400603900302 · Cited by 1
The measurement of body composition by infrared interactance: An evaluation
Polito, A., Pařízková, J., Toti, E., & Ferro-Luzzi, A. (1994) · Nutrition Research · doi:10.1016/s0271-5317(05)80244-1 · Cited by 1
Development of a new simple estimating method for protein, fat, and carbohydrate in cooked foods.
Kumae, T. (2000) · Environmental Health and Preventive Medicine · doi:10.1007/bf02931259 · Cited by 1
Physical training and testing in patients with chronic obstructive pulmonary disease
Arnardóttir, R. H. (2007) · The Clinical Respiratory Journal · doi:10.1111/j.1752-699x.2007.00011.x · Cited by 1
Schlup, M., Chang, A. R., Chadwick, D., Ferry, D. M., & CHADWICK, V. S. (1993) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365529309098300 · Cited by 1
Pagnacco, G., Bundle, M. W., Carrick, F. R., Wright, C., & Oggero, E. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2013.12.019 · Cited by 1
Scafoglieri, A., Provyn, S., Louis, G. M. B., Wallace, J. A., Mey, J. D., & Clarys, J. P. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-13039-7_138 · Cited by 1
Mehr Qualität – oder mehr Kontrolle? Beyond analytical quality control
Hagemann, P. (2006) · Journal of Laboratory Medicine · doi:10.1515/jlm.2006.008 · Cited by 1
Automatic Ventricular Threshold Measurement in Children with Epicardial Pacing Leads
Hiippala, A., CLAUSSON, E., Ekblad, H., Leskinen, M., & Happonen, J.-M. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00289.x · Cited by 1
Parallel line bioassay or single-point calibration for the establishment of reference ranges
Tosetto, A., Gatto, E., Masiero, M. T., & Rodeghiero, F. (1994) · Thrombosis Research · doi:10.1016/0049-3848(94)90263-1 · Cited by 1
Wietasch, G. J. K. G., Hoeft, A., Bühre, W., Weyland, A., Scholz, M., Allgeier, B., Bürsch, J. H., & Sonntag, H. (1994) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(94)90348-4 · Cited by 1
Escaned, J., Doriot, P. A., Mario, C. D., Foley, D. P., Haase, J., Baptista, J., Meneveau, N. F., den Boer, A., Ligthart, J. M. R., Roelandt, J. R. T. C., et al. (1994) · Developments in cardiovascular medicine · doi:10.1007/978-94-015-8358-9_37 · Cited by 1
A NOVEL PROTAMINE SENSOR FOR MEASUREMENT OF HEPARIN LEVELS IN BLOOD AND PLASMA
Baliga, N., Ramamurthy, N., Meyerhoff, M. E., Yang, V. C.-M., & Wahr, J. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199804001-00026 · Cited by 1
Monitoring gaseous exchange: Implications for nursing care
Martin, S., & Wilson, M. (2002) · Australian Critical Care · doi:10.1016/s1036-7314(02)80038-8 · Cited by 1
Sivarajan, M., Klues, H. G., Krebs, W., Steinert, S., Franke, A., Janssens, U., & Hanrath, P. (2000) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(00)90006-5 · Cited by 1
Lagier, P., Vialet, R., Léger, E. S., Lemaire, P., & Granthil, C. (1992) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/s0750-7658(05)80343-0 · Cited by 1
Different value scales between frequency‐doubling technique and standard threshold perimetry
Iester, M., Traverso, C. E., Capris, P., Vittone, P., & Zingirian, M. (2000) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.2000.tb01086.x · Cited by 1
Effect of heparinization of catheters on pulmonary artery oximetry
Stritter, G. M., Pearl, R. G., & Mihm, F. G. (1988) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01621817 · Cited by 1
Martínez, M. A. E., de Asúa, D. R., Torres, R. J., Bernardino, J. I., Pallardo, L. F., & García‐Puig, J. (2007) · Revista Clínica Española · doi:10.1016/s0014-2565(07)73438-0 · Cited by 1
The Incidence of Post-operative Hypoxaemia Following Lobectomy and Pneumonectomy: A pilot study
Leaver, H., Conway, J. H., & Holgate, S. (1994) · Physiotherapy · doi:10.1016/s0031-9406(10)60843-7 · Cited by 1
Estimates of Interventricular Septum Thickness Are Markedly Affected by the Method Used
Poutanen, T., & Tikanoja, T. (2003) · Pediatric Cardiology · doi:10.1007/s00246-002-0296-z · Cited by 1
Thoracic impedance tracing in perioperative hemodynamic monitoring: a technique to be revisited
Favaro, M., Allaria, B., & Resta, M. V. (2003) · Springer eBooks · doi:10.1007/978-88-470-2215-7_12 · Cited by 1
Nakamura, F. Y., Borges, T. O., De‐Oliveira, F. R., Soares-Caldeira, L. F., Bertuzzi, R., & Matsushigue, K. A. (2008) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922008000500003 · Cited by 1
A New Noninvasive Method for the Accurate and Precise Assessment of Varicose Vein Diameters
Baldassarre, D., Pustina, L., Castelnuovo, S., Bondioli, A., Carlà, M., & Sirtori, C. R. (2003) · Angiology · doi:10.1177/000331970305400503 · Cited by 1
Comparison of Chemcard Cholesterol test and laboratory cholesterol measurements
Gan, I. E. T., & Schier, G. M. (1995) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1995.tb02860.x · Cited by 1
In vivo determinants of arterial biophysical properties: methodological considerations
Lehmann, E. D., & Gosling, R. G. (1997) · Atherosclerosis · doi:10.1016/s0021-9150(97)00178-0 · Cited by 1
Cron, T. A., Zellweger, M. J., Buser, P. T., Pfisterer, M. E., & Osswald, S. (2002) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2002.tb00178.x · Cited by 1
Clinical evaluation of the new BMU 40 in-line blood analysis monitor
Schaarschmidt, J., Seeburger, J., Borger, M. A., Grosse, F. O., Kraemer, K., & Mohr, F. W. (2009) · Perfusion · doi:10.1177/0267659109350935 · Cited by 1
Gall stones induced by octreotide.
Catnach, S. M., Wass, J. A. H., Anderson, J. V., Besser, M., Fairclough, P. D., Hussaini, H. S., & Dowling, H. (1992) · BMJ · doi:10.1136/bmj.305.6848.313 · Cited by 1
Essai contrôlé d'un moniteur continu non invasif de pression artérielle, l'APM 770 Cortronic
Caramella, J. P., Hidou, M., & Claude, E. V. (1991) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/s0750-7658(05)80844-5 · Cited by 1
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.