STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 5,801–5,900 of 47,868
Measurement of Scleral Thickness in Humans Using Anterior Segment Optical Coherent Tomography
Buckhurst, H. D., Gilmartin, B., Cubbidge, R. P., & Logan, N. S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0132902 · Cited by 78
A maturation model for midazolam clearance
Anderson, B. J., & Larsson, P. (2010) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2010.03364.x · Cited by 81
Chiappini, E., Sollai, S., Longhi, R., Morandini, L., Laghi, A., Osio, C. E., Persiani, M., Lonati, S., Picchi, R., Bonsignori, F., et al. (2011) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2010.03565.x · Cited by 77
Hise, M. E., Sullivan, D. K., JACOBSEN, D. J., Johnson, S. L., & Donnelly, J. E. (2002) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.2.263 · Cited by 97
Da Costa, A. (2002) · European Heart Journal · doi:10.1053/euhj.2001.2819 · Cited by 81
Zhao, Y., Tan, C., & Tong, L. H. T. (2015) · BMC Ophthalmology · doi:10.1186/s12886-015-0036-9 · Cited by 78
Wess, G., & Reusch, C. E. (2000) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2000.tb03164.x · Cited by 98
Gait event detection for use in FES rehabilitation by radial and tangential foot accelerations
Rüterbories, J., Spaich, E. G., & Andersen, O. K. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.10.004 · Cited by 81
Costing Hospital Surgery Services: The Method Matters
Mercier, G., & Naro, G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0097290 · Cited by 96
Verdich, C., Barbe, P., Petersen, M., Grau, K., Ward, L. C., Macdonald, I. A., Sørensen, T. I. A., & Oppert, J. (2011) · Diabetes & Metabolism · doi:10.1016/j.diabet.2010.10.007 · Cited by 91
Cardiac Output Monitoring: Is There a Gold Standard and How Do the Newer Technologies Compare?
Pugsley, J., & Lerner, A. B. (2010) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253210386386 · Cited by 78
Evaluation of the Omron HJ-720ITC Pedometer under Free-Living Conditions
SILCOTT, N. A., BASSETT, D. R., THOMPSON, D. L., FITZHUGH, E. C., & STEEVES, J. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318212888c · Cited by 78
Precision of QT Interval Measurement by Advanced Electrocardiographic Equipment
Hnatkova, K., Gang, Y., Batchvarov, V. N., & Malík, M. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00532.x · Cited by 78
Comparison of spirometric reference values
Subbarao, P., Lebecque, P., Corey, M. L., & Coates, A. L. (2004) · Pediatric Pulmonology · doi:10.1002/ppul.20015 · Cited by 86
Daily step counts in a US cohort with COPD
Moy, M. L., Danilack, V. A., Weston, N. A., & Garshick, E. (2012) · Respiratory Medicine · doi:10.1016/j.rmed.2012.03.016 · Cited by 90
Janik, M. J., Cham, M. D., Ross, M. I., Wang, Y., Codella, N., Min, J. K., Prince, M. R., Manoushagian, S. J., Okin, P. M., Devereux, R. B., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328302ca14 · Cited by 83
Delayed Calf Muscle Phosphocreatine Recovery After Exercise Identifies Peripheral Arterial Disease
Isbell, D. C., Berr, S. S., Toledano, A. Y., Epstein, F. H., Meyer, C. H., Rogers, W. J., Harthun, N. L., Hagspiel, K. D., WELTMAN, A. L., & Kramer, C. M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.069 · Cited by 78
Rathleff, C. R., Baird, W. N., Olesen, J. L., Roos, E. M., Rasmussen, S., & Rathleff, M. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079153 · Cited by 89
Konigsberg, B. S., Hess, R., Hartman, C. W., Smith, L., & Garvin, K. L. (2013) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-013-3111-7 · Cited by 78
Stability of dietary patterns in young women over a 2-year period
Borland, S. E., Robinson, S. M., Crozier, S., Inskip, H. M., & and the SWS Study Group (2007) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602684 · Cited by 92
Ultrasonic measurement of enamel thickness: a tool for monitoring dental erosion?
Huysmans, M. C. D. N. J. M., & THIJSSEN, J. M. (2000) · Journal of Dentistry · doi:10.1016/s0300-5712(99)00063-9 · Cited by 78
Mannion, A. F., Klein, G. N., Dvořák, J., & Lanz, C. (2000) · European Spine Journal · doi:10.1007/s005860000187 · Cited by 78
Poostchi, A., Mitchell, R., Nicholas, S., Purdie, G., & Wells, A. P. (2009) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2009.02109.x · Cited by 78
Lagali, N., Germundsson, J., & Fagerholm, P. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3781 · Cited by 106
Adults’ Past-Day Recall of Sedentary Time: Reliability, Validity, and Responsiveness
Clark, B., WINKLER, E. A. H., Healy, G. N., Gardiner, P. A., Dunstan, D. W., Owen, N. G., & Reeves, M. M. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182837f57 · Cited by 89
Diagnostic accuracy of sleep bruxism scoring in absence of audio-video recording: a pilot study
Carra, M. C., Huynh, N. T., & Lavigne, G. J. (2014) · Sleep And Breathing · doi:10.1007/s11325-014-0986-9 · Cited by 78
Cardiac Output Estimation With a New Doppler Device After Off-Pump Coronary Artery Bypass Surgery
Chand, R. K., Mehta, Y. B., & Trehan, N. K. (2006) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2005.05.024 · Cited by 78
Müller, K., & Brunnberg, L. (2009) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2009.00177.x · Cited by 78
Physicians’ Ability to Predict Patients’ Adherence to Antihypertensive Medication in Primary Care
ZELLER, A., TAEGTMEYER, A., MARTINA, B., BATTEGAY, E., & TSCHUDI, P. (2008) · Hypertension Research · doi:10.1291/hypres.31.1765 · Cited by 79
Chen, G., Meng, L., Alexander, B. S., Tran, N. P., Kain, Z. N., & Cannesson, M. P. (2012) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2011.08.014 · Cited by 78
Kanters, S. D. J. M., Elgersma, O. E. H., Banga, J.-D., van Leeuwen, M. S., & Algra, A. (1998) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/s1078-5884(98)80088-9 · Cited by 78
Validation of Actigraph accelerometer estimates of total energy expenditure in young children
Reilly, J. J., Kelly, L. A., Montgomery, C., Jackson, D. M., Slater, C., Grant, S., & Paton, J. Y. (2006) · International Journal of Pediatric Obesity · doi:10.1080/17477160600845051 · Cited by 78
Danner, N., Julkunen, P., Könönen, M., Säïsänen, L., Nurkkala, J., & Karhu, J. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.032 · Cited by 93
Assessment of brain midline shift using sonography in neurosurgical ICU patients
Motuel, J., Biette, I., Srairi, M., Mrozek, S., Kurrek, M. M., Chaynes, P., Cognard, C., Fourcade, O., & Geeraerts, T. (2014) · Critical Care · doi:10.1186/s13054-014-0676-9 · Cited by 78
Stöckl, D., D’Hondt, H., & Thienpont, L. M. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.12.056 · Cited by 78
Toyoda, T., Baba, H., Akasaka, T., Akiyama, M., Neishi, Y., Tomita, J., Sukmawan, R., Koyama, Y., Watanabe, N., Tamano, S., et al. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.07.010 · Cited by 78
What is the best way to measure waist circumference?
RUDOLF, M. C. J., Walker, J., & Cole, T. J. (2007) · International Journal of Pediatric Obesity · doi:10.1080/17477160601095177 · Cited by 78
Clements, J. M., & Pirie, R. S. (2007) · Research in Veterinary Science · doi:10.1016/j.rvsc.2006.12.002 · Cited by 78
Marini, R. D., Rozet, E., Montes, M. L., Rohrbasser, C., Roht, S., Rhême, D., Bonnabry, P., Schappler, J., Veuthey, J., Hubert, P., et al. (2010) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2010.07.026 · Cited by 78
Rough Guide to the Fugl-Meyer Assessment
Deakin, A., Hill, H., & Pomeroy, V. M. (2003) · Physiotherapy · doi:10.1016/s0031-9406(05)60502-0 · Cited by 98
Biometric measurements of the eyes in teenagers and young adults with Down syndrome
Haugen, O. H., Høvding, G., & Eide, G. E. (2001) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.2001.790613.x · Cited by 78
Nishimura, A., & Sawai, T. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2006.03.008 · Cited by 82
Clinical and patho-anatomical factors affecting expansion of thoracic aortic aneurysms
Bonser, R. S., Pagano, D., Lewis, M. E., Rooney, S. J., Guest, P., Davies, P., & Shimada, I. (2000) · Heart · doi:10.1136/heart.84.3.277 · Cited by 81
Schadewaldt, P., Nowotny, B., Straßburger, K., Kotzka, J., & Roden, M. (2013) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.112.035014 · Cited by 88
Giannoglou, G. D., Chatzizisis, Y. S., Koutkias, V. G., Kompatsiaris, I. Y., Papadogiorgaki, M., Mezaris, V., Parissi, E., Diamantopoulos, P., Strintzis, M. G., Maglaveras, N., et al. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2006.12.003 · Cited by 78
Automated Detection of Macular Drusen Using Geometric Background Leveling and Threshold Selection
Smith, R. T., Chan, J. K. W., Nagasaki, T., Ahmad, U. F., Barbazetto, I., Sparrow, J., Figueroa, M., & Merriam, J. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.2.200 · Cited by 85
A real-time device for converting Doppler ultrasound audio signals into fluid flow velocity
Herr, M. D., Hogeman, C. S., Koch, D. W., Krishnan, A., Momen, A., & Leuenberger, U. A. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00713.2009 · Cited by 78
Singer, L., Wilmes, L. J., Sarıtaş, E. Ü., Shankaranarayanan, A., Proctor, E., Wisner, D. J., Chang, B., Joe, B. N., Nishimura, D. G., & Hylton, N. M. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.11.003 · Cited by 78
Soltani, A., Reid, D. W., Sohal, S. S., Wood-Baker, R. R., Weston, S., Muller, H. K., & Walters, E. H. (2010) · Respiratory Research · doi:10.1186/1465-9921-11-105 · Cited by 78
Baker, P. N., Nanda, R., Goodchild, L. M., Finn, P., & Rangan, A. (2007) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2007.04.019 · Cited by 78
A review of ultrasound common carotid artery image and video segmentation techniques
Loizou, C. P. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1203-5 · Cited by 89
Ong, A. M. L., Hillman, S. J., & Robb, J. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.008 · Cited by 78
Lin, S. J., Brown, P. A., Watkins, M. P., Williams, T. A., Lehr, K. A., Liu, W., Lanza, G. M., Wickline, S. A., & Caruthers, S. D. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.038 · Cited by 83
Changes in Airway Dimensions on Computed Tomography Scans of Children with Cystic Fibrosis
de Jong, P. A., Nakano, Y., Hop, W. C. J., Long, F. R., Coxson, H. O., Paré, P. D., & Tiddens, H. A. W. M. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1311oc · Cited by 80
Test-Retest Reliability of Adult Surveillance Measures for Physical Activity and Inactivity
Evenson, K. R., & McGinn, A. (2005) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2005.02.005 · Cited by 78
Surgically induced corneal refractive change following glaucoma surgery
Eğrilmez, S., Ateş, H., Nalçacı, S., Andaç, K., & Yağcı, A. (2004) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2003.11.055 · Cited by 78
Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography
Bouvier, E., Logeart, D., Sablayrolles, J., Feignoux, J., Scheublé, C., Touche, T., Thabut, G., & Solal, A. C. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl273 · Cited by 78
Cordonnier, M., & Dramaix, M. (1999) · British Journal of Ophthalmology · doi:10.1136/bjo.83.2.157 · Cited by 78
Ireland, A. J., Hosein, I., & Sherriff, M. (2005) · European Journal of Orthodontics · doi:10.1093/ejo/cji031 · Cited by 97
Acute splenic responses in patients with ischemic stroke and intracerebral hemorrhage
Vahidy, F., Parsha, K., Rahbar, M. H., Lee, M., Bui, T., Nguyen, C. B., Barreto, A. D., Bambhroliya, A. B., Sahota, P., Yang, B., et al. (2015) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x15607880 · Cited by 81
Estimating blood pressure using Windkessel model on photoplethysmogram
Choudhury, A. D., Banerjee, R., Sinha, A., & Kundu, S. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944640 · Cited by 78
Calvo‐Lobo, C., Pacheco‐da‐Costa, S., Martínez-Martínez, J., Rodríguez‐Sanz, D., Cuesta-Álvaro, P., & López‐López, D. (2016) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0000000000000079 · Cited by 81
The Effect of Age, Accommodation, and Refractive Error on the Adult Human Eye
Richdale, K., Bullimore, M. A., Sinnott, L. T., & Zadnik, K. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000757 · Cited by 78
Probabilistic forecasting in infectious disease epidemiology: the 13th Armitage lecture
Held, L., Meyer, S., & Bracher, J. (2017) · Statistics in Medicine · doi:10.1002/sim.7363 · Cited by 101
Validation of the Nox-T3 Portable Monitor for Diagnosis of Obstructive Sleep Apnea in Chinese Adults
Xu, L., Han, F., Keenan, B. T., Kneeland-Szanto, E., Yan, H., Dong, X., Chang, Y., Zhao, L., Zhang, X., Li, J., et al. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6582 · Cited by 86
Hughes, S. W., D’Arcy, T. J., Maxwell, D. J., Chiu, W. S. C., Milner, A. D., Saunders, J. E., & Sheppard, R. J. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(96)00022-1 · Cited by 78
Orbital helical computed tomography in the diagnosis and management of eye trauma
Lakits, A., PROKESCH, R. W., Scholda, C. D., & Bankier, A. A. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90536-5 · Cited by 78
Corley, K. T. T., Donaldson, L. L., & Furr, M. O. (2002) · Equine Veterinary Journal · doi:10.2746/042516402776180287 · Cited by 78
Validation of the Welch Allyn ‘Vital Signs’ oscillometric blood pressure monitor
Jones, C., Taylor, K., Poston, L., & Ah, S.-N. (2000) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001141 · Cited by 88
Expression of interleukin (IL)-4 and IL-5 proteins in asthma induced by toluene diisocyanate (TDI)
Maestrelli, P., OCCARI, P., Turato, G., Papiris, S. A., STEEANO, A. D., Mapp, C. E., MILANI, G. F., EABBRI, L. M., & Saetta, M. P. (1997) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.1997.1560958.x · Cited by 79
Bird, P., Lassere, M. N., Shnier, R., & Edmonds, J. P. (2003) · Arthritis & Rheumatism · doi:10.1002/art.10820 · Cited by 78
Urea volume of distribution exceeds total body water in patients with acute renal failure
Himmelfarb, J., Evanson, J., Hakim, R. M., Freedman, S., Shyr, Y., & Ikizler, T. A. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00118.x · Cited by 83
Gautrin, D., D'Aquino, C., Gagnon, G., Malo, J., & Cartier, A. (1994) · CHEST Journal · doi:10.1378/chest.106.5.1419 · Cited by 82
Brouwer, S., Dijkstra, P., Stewart, R. E., Göeken, L., Groothoff, J., & Geertzen, J. H. B. (2005) · Disability and Rehabilitation · doi:10.1080/09638280500052823 · Cited by 78
SIMONE, G. D., Muiesan, M. L., Ganau, A., LONGHINI, C., Verdecchia, P., Palmieri, V., Agabiti‐Rosei, E., & Mancia, G. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917121-00027 · Cited by 90
Dynamic MRI of Invasive Breast Cancer: Assessment of Three Region-of-Interest Analysis Methods
MUSSURAKIS, S., Buckley, D. L., & Horsman, A. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199705000-00017 · Cited by 78
Hofstad, B., Vatn, M., Larsen, S., & OSNES, M. (1994) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365529409092485 · Cited by 82
Evaluation of Dual-Energy X-Ray Absorptiometry for Body-Composition Assessment in Rats
Bertin, É., Ruiz, J.-C., Mourot, J., Peiniau, P., & Portha, B. (1998) · Journal of Nutrition · doi:10.1093/jn/128.9.1550 · Cited by 89
Value of QT Dispersion in the Interpretation of Exercise Stress Test in Women
Stoletniy, L. N., & Pai, R. G. (1997) · Circulation · doi:10.1161/01.cir.96.3.904 · Cited by 78
Test—retest reliability of the StepWatch Activity Monitor outputs in individuals with chronic stroke
Mudge, S., & Stott, N. S. (2008) · Clinical Rehabilitation · doi:10.1177/0269215508092822 · Cited by 77
Pinnington, H. C., Wong, P., Tay, J., Green, D., & Dawson, B. (2001) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(01)80041-4 · Cited by 77
Fields, D. A., Demerath, E. W., Pietrobelli, A., & Chandler-Laney, P. C. (2012) · Obesity · doi:10.1038/oby.2012.102 · Cited by 82
Böttiger, B. W., Rauch, H., Bohrer, H., Motsch, J., Soder, M., Fleischer, F., & Martin, E. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80095-3 · Cited by 77
Domenichini, G., Sunthorn, H., Fleury, E., Foulkes, H., Stettler, C., & Burri, H. (2012) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2012.03.012 · Cited by 77
CIEL⁎a⁎b⁎ color space predictive models for colorimetry devices – Analysisof perfume quality
Korifi, R., Dréau, Y. L., Antinelli, J.-F., Valls, R., & Dupuy, N. (2012) · Talanta · doi:10.1016/j.talanta.2012.11.026 · Cited by 77
Morphologic Characterization of Pulmonary Nodules With Ultrashort TE MRI at 3T
Wielpütz, M. O., Lee, H. Y., Koyama, H., Yoshikawa, T., Seki, S., Kishida, Y., Sakai, Y., Kauczor, H., Sugimura, K., & Ohno, Y. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.18961 · Cited by 77
Reddy, R. S., Alahmari, K. A., Samuel, P. S., Ahmad, I., Kakaraparthi, V. N., & Rengaramanujam, K. (2019) · Canadian Respiratory Journal · doi:10.1155/2019/5175949 · Cited by 81
Perich, G., Hund, A., Anderegg, J., Roth, L., Boer, M. P., Walter, A., Liebisch, F., & Aasen, H. (2020) · Frontiers in Plant Science · doi:10.3389/fpls.2020.00150 · Cited by 85
A novel device for detecting anaerobic threshold using sweat lactate during exercise
Seki, Y., Nakashima, D., Shiraishi, Y., Ryuzaki, T., Ikura, H., Miura, K., Suzuki, M., Watanabe, T., Nagura, T., Matsumato, M., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-84381-9 · Cited by 86
ChatGPT Needs a Chemistry Tutor Too
Leon, A. J., & Vidhani, D. (2023) · Journal of Chemical Education · doi:10.1021/acs.jchemed.3c00288 · Cited by 65
Putnam, O. C., McFayden, T. C., & Harrop, C. (2024) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-024-06498-w · Cited by 82
Mullix, J., Warner, M. B., & Stokes, M. J. (2012) · ePrints Soton (University of Southampton) · Cited by 77
Kim, S. W., Byun, Y., Kim, E. K., & Kim, T. (2007) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20071101-04 · Cited by 77
Comparison of Two Different Speckle Tracking Software Systems: Does the Method Matter?
Biaggi, P., Carasso, S., Garceau, P., Greutmann, M., Gruner, C., Tsang, W., Rakowski, H., Agmon, Y., & Woo, A. (2011) · Echocardiography · doi:10.1111/j.1540-8175.2011.01386.x · Cited by 81
Zaki, R. A., Bulgiba, A. M., Nordin, N., & Ismail, N. A. (2013) · PubMed Central · Cited by 96
Uloza, V., Padervinskis, E., Vegienė, A., Pribuišienė, R., Šaferis, V., Vaičiukynas, E., Gelžinis, A., & Verikas, A. (2015) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-015-3708-4 · Cited by 86
Rasmussen, H. M., Nielsen, D. B., Pedersen, N. W., Overgaard, S., & Holsgaard‐Larsen, A. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.04.019 · Cited by 93
Oxborough, D., George, K., & Birch, K. M. (2012) · Echocardiography · doi:10.1111/j.1540-8175.2012.01698.x · Cited by 90
Buller, M. J., Tharion, W. J., Duhamel, C. M., & Yokota, M. (2015) · Ergonomics · doi:10.1080/00140139.2015.1036792 · Cited by 75
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.