STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 6,001–6,100 of 47,868
Inter-observer agreement in the assessment of endoscopic findings in ulcerative colitis
de Lange, T., Larsen, S., & Aabakken, L. (2004) · BMC Gastroenterology · doi:10.1186/1471-230x-4-9 · Cited by 84
Merce, L. T., Gómez, B., Engels, V., Bau, S., & Bajo, J. (2005) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2005.24.9.1279 · Cited by 76
Reifferscheid, F., Elke, G., Pulletz, S., Gawelczyk, B., Lautenschläger, I., Steinfath, M., Weiler, N., & Frerichs, I. (2011) · Respirology · doi:10.1111/j.1440-1843.2011.01929.x · Cited by 352
Accuracy of Weight and Height Estimation in an Intensive Care Unit
Maskin, L. P., Attie, S., Setten, M. G., Rodríguez, P., Bonelli, I., Stryjewski, M. E., & Valentini, R. N. (2010) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1003800519 · Cited by 84
Myocardial Ultrasonic Backscatter in Hypertension
Kozàkovà, M., Buralli, S., Palombo, C., Bernini, G. P., Moretti, A., Favilla, S., Taddei, S., & Salvetti, A. (2003) · Hypertension · doi:10.1161/01.hyp.0000052542.68896.2b · Cited by 76
Reproducibility of BOLD signal change induced by breath holding
Magon, S., Basso, G., Farace, P., Ricciardi, G. K., Beltramello, A., & Sbarbati, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.059 · Cited by 85
de Langen, A. J., Klabbers, B. M., Lubberink, M., Boellaard, R., Spreeuwenberg, M. D., Slotman, B. J., de Bree, R., Smit, E. F., Hoekstra, O. S., & Lammertsma, A. A. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0960-5 · Cited by 76
Passive knee extension test to measure hamstring muscle tightness
Fredriksen, H., Dagfinrud, H. S., Jacobsen, V., & Mæhlum, S. (1997) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.1997.tb00153.x · Cited by 95
Rapid automated cell quantification on HIV microfluidic devices
Alyassin, M. A., Moon, S., Keleş, H. O., Manzur, F., Lin, R. L., Hæggström, E., Kuritzkes, D. R., & Demirci, U. (2009) · Lab on a Chip · doi:10.1039/b911882a · Cited by 82
Assumed oxygen consumption frequently results in large errors in the determination of cardiac output
Fakler, U., Pauli, C., Hennig, M., Sebening, W., & Hess, J. (2005) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.02.048 · Cited by 76
Laidlaw, D. A. H., Abbott, A., & Rosser, D. A. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.10.1232 · Cited by 78
Vasseljen, O., Dahl, H. H., Mork, P. J., & Torp, H. G. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.05.003 · Cited by 76
Kume, K., Amano, K., Yamada, S., Amano, K., Kuwaba, N., & Ohta, H. (2011) · Journal of Hand Surgery (European Volume) · doi:10.1177/1753193411427829 · Cited by 76
Strain, G. W., Wang, J., Gagner, M., Pomp, A., Inabnet, W. B., & Heymsfield, S. B. (2008) · Obesity · doi:10.1038/oby.2008.321 · Cited by 76
Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs
Sawyer, D. C., Guikema, A. H., & Siegel, E. M. (2004) · Veterinary Anaesthesia and Analgesia · doi:10.1111/j.1467-2995.2004.00141.x · Cited by 85
Goldoni, M., Caglieri, A., Poli, D., Vettori, M. V., Corradi, M., Apostoli, P., & Mutti, A. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.01.065 · Cited by 76
Pathoanatomic Mechanisms of Degenerative Spondylolisthesis
Nagaosa, Y., Kikuchi, S., HASUE, M., & Sato, S. (1998) · Spine · doi:10.1097/00007632-199807010-00004 · Cited by 76
Meckel, S., Leitner, L., Bonati, L. H., Santini, F., Schubert, T. B., Stalder, A. F., Lyrer, P. A., Markl, M., & Wetzel, S. G. (2012) · Neuroradiology · doi:10.1007/s00234-012-1103-z · Cited by 76
Intermonitor Variability of GT3X Accelerometer
Santos-Lozano, A., Torres-Luque, G., Marín, P., Ruiz, J., Lucia, A., & Garatachea, N. (2012) · International Journal of Sports Medicine · doi:10.1055/s-0032-1312580 · Cited by 76
Lejeune, D., Souletie, I., Houzé, S., Bricon, T. L., Bras, J. L., Gourmel, B., & Houzé, P. (2006) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2006.09.036 · Cited by 77
Salinas, M., Rosas, J., Iborra, J., Manero, H., & Pascual, E. (1997) · Annals of the Rheumatic Diseases · doi:10.1136/ard.56.10.622 · Cited by 76
Magnetic resonance imaging of patellofemoral relationships
Koskinen, S. K., TAIMELA, S. P., Nelimarkka, O., Komu, M. E. S., & Kujala, U. M. (1993) · Skeletal Radiology · doi:10.1007/bf00538441 · Cited by 76
Sugeng, L., Weinert, L., Lammertin, G., Thomas, P., Spencer, K. T., DeCara, J. M., Mor‐Avi, V., Huo, D., Feldman, T. E., & Lang, R. M. (2003) · Journal of the American Society of Echocardiography · doi:10.1067/j.echo.2003.07.005 · Cited by 76
Reliability of handheld dynamometry in assessment of hip strength in adult male football players
Fulcher, M. L., Hanna, C. M., & Elley, C. R. (2009) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2008.11.007 · Cited by 76
Validation of a Shortened Electronic Version of the Environmental Symptoms Questionnaire
Beidleman, B. A., Muza, S. R., Fulco, C. S., Rock, P. B., & Cymerman, A. (2007) · High Altitude Medicine & Biology · doi:10.1089/ham.2007.1016 · Cited by 80
Buehl, W., Findl, O., Menapace, R., Georgopoulos, M., Rainer, G., Wirtitsch, M. G., Siegl, H., & Pinz, A. J. (2002) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(01)01228-7 · Cited by 76
Baron, G., Tubach, F., Ravaud, P., Logeart, I., & Dougados, M. (2007) · Arthritis Care & Research · doi:10.1002/art.22685 · Cited by 86
Neuhaus, K. W., Rodrigues, J. A., Hug, I., Stich, H., & Lussi, A. (2010) · Clinical Oral Investigations · doi:10.1007/s00784-010-0427-5 · Cited by 89
Kim, W. Y., Jun, J. H., Huh, J. W., Hong, S. B., Lim, C., & Koh, Y. (2013) · Shock · doi:10.1097/shk.0000000000000064 · Cited by 76
van der Leeden, M., Steultjens, M. P. M., Terwee, C. B., Rosenbaum, D., Turner, D., Woodburn, J., & Dekker, J. (2008) · Arthritis Care & Research · doi:10.1002/art.24016 · Cited by 76
Repeatability of echocardiographic measurements in the human fetus
Simpson, J. M., & Cook, A. C. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2002.00799.x · Cited by 76
Merle, C., Waldstein, W., Pegg, E. C., Streit, M. R., Gotterbarm, T., Aldinger, P. R., Murray, D. W., & Gill, H. S. (2012) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.94b4.28067 · Cited by 76
Ruskin, D., Lalloo, C., Amaria, K., Stinson, J. N., Kewley, E., Campbell, F., Brown, S. C., Jeavons, M., & McGrath, P. A. (2014) · Pain Research and Management · doi:10.1155/2014/856513 · Cited by 73
Cox-Reijven, P. L. M., & Soeters, P. B. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801123 · Cited by 90
Daniel, J., Ziaee, H., Pynsent, P. B., & McMinn, D. J. W. (2007) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.89b6.18141 · Cited by 76
Hu, K., Peng, C., Czosnyka, M., Zhao, P., & Novak, V. (2007) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-007-9045-5 · Cited by 81
Ageberg, E., Roberts, D., Holmström, E., & Fridén, T. (2003) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-4-14 · Cited by 78
Temperature measurement: comparison of non‐invasive methods used in adult critical care
Farnell, S., Maxwell, L., Tan, S. S., Rhodes, A., & Philips, B. J. (2005) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2004.00916.x · Cited by 76
Fuchs, T., Frick, K., Emde, B., Czasch, S., von Landenberg, F., & Hewitt, P. (2012) · Toxicologic pathology (Print) · doi:10.1177/0192623312444618 · Cited by 72
Lavanya, R., Teo, L., Friedman, D. S., Aung, H. T., Baskaran, M., Gao, H., Alfred, T., Seah, S., Kashiwagi, K., Foster, P. J., et al. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2006.113761 · Cited by 77
Jerrard-Dunne, P., Sitzer, M., Risley, P., Steckel, D. A., Buehler, A., von Kegler, S., & Markus, H. S. (2003) · Stroke · doi:10.1161/01.str.0000053849.09308.b2 · Cited by 76
MRI Findings in Painful Metal-on-Metal Hip Arthroplasty
Hayter, C. L., Gold, S. L., Koff, M. F., Perino, G., Nawabi, D. H., Miller, T. T., & Potter, H. G. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.8203 · Cited by 76
In-Vitro and In-Vivo Trans-Scalp Evaluation of an Intracranial Pressure Implant at 2.4 GHz
Kawoos, U., Tofighi, M.-R., Warty, R., Kralick, F., & Rosen, A. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2004253 · Cited by 76
Eston, R. G., Lambrick, D., Sheppard, K., & Parfitt, G. (2007) · Journal of Sports Sciences · doi:10.1080/02640410701371364 · Cited by 91
Elbers, R. G., van Wegen, E. E. H., Verhoef, J., & Kwakkel, G. (2012) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2012.01.024 · Cited by 88
Stefanidis, K., Dimopoulos, S. K., Tripodaki, E., Vitzilaios, K., Politis, P., Piperopoulos, P. N., & Nanas, S. (2011) · Critical Care · doi:10.1186/cc10338 · Cited by 77
Waldron, N. H., Miller, T. E., Thacker, J. K. M., Manchester, A. K., White, W. D., Nardiello, J., Elgasim, M. A., Moon, R. E., & Gan, T. J. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000182 · Cited by 76
Cigar smoking has an acute detrimental effect on arterial stiffness
Vlachopoulos, C. (2004) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2003.12.014 · Cited by 76
Evenson, K. R., & Wen, F. (2010) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-7-21 · Cited by 77
Measuring continuity of care: psychometric properties of the Nijmegen Continuity Questionnaire
Uijen, A. A., Schers, H., Schellevis, F., Mokkink, H. G. A., van Weel, C., & van den Bosch, W. J. (2012) · British Journal of General Practice · doi:10.3399/bjgp12x652364 · Cited by 86
Bailey, B., Bergeron, S., Gravel, J., & Daoust, R. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.04.021 · Cited by 87
Revitalizing a Vital Sign: Improving Detection of Tachypnea at Primary Triage
Bianchi, W., Dugas, A. F., Hsieh, Y., Saheed, M. O., Hill, P., Lindauer, C., Terzis, A., & Rothman, R. E. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2012.05.030 · Cited by 78
The Most Effective Exercise for Strengthening the Supraspinatus Muscle
Takeda, Y., Kashiwaguchi, S., Endo, K., Matsuura, T., & Sasa, T. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300031201 · Cited by 76
Deurenberg, P., & Deurenberg‐Yap, M. (2002) · Asia Pacific Journal of Clinical Nutrition · doi:10.1046/j.1440-6047.2002.00258.x · Cited by 79
Results of the performance verification of the CoaguChek XS system
Plesch, W., Wolf, T., Breitenbeck, N., Dikkeschei, L. D., Cervero, A., Pérez, P., & van den Besselaar, A. M. H. P. (2008) · Thrombosis Research · doi:10.1016/j.thromres.2008.04.021 · Cited by 76
Brill, S., Law, M., El‐Emir, E., Allinson, J. P., James, P. L., Maddox, V., Donaldson, G. C., McHugh, T. D., Cookson, W., Moffatt, M. F., et al. (2015) · Thorax · doi:10.1136/thoraxjnl-2015-207194 · Cited by 87
Anwar, A. M., Geleijnse, M. L., ten Cate, F. J., & Meijboom, F. J. (2006) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2006.132381 · Cited by 76
Characteristics of Optic Disc Rotation in Myopic Eyes
Sung, M. S., Kang, Y. S., Heo, H., & Park, S. W. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.10.018 · Cited by 76
Trotta, A. M., Ottaiano, A., Romano, C., Nasti, G., Nappi, A. G., Divitiis, C. D., Napolitano, M., Zanotta, S., Casaretti, R., D’Alterio, C., et al. (2016) · Cancer Immunology Research · doi:10.1158/2326-6066.cir-15-0184 · Cited by 86
Spectral-Cepstral Estimation of Dysphonia Severity: External Validation
Awan, S. N., Solomon, N. P., Helou, L. B., & Stojadinovic, A. (2013) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348941312200108 · Cited by 76
Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory
Usman, M., Ruijsink, B., Nazir, M. S., da Cruz, G. J. L., & Prieto, C. (2016) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.12.021 · Cited by 89
Heil, A., Gonzalez, E. L., Hilgenfeld, T., Kickingereder, P., Bendszus, M., Heiland, S., Ozga, A., Sommer, A., Lux, C. J., & Zingler, S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0174524 · Cited by 78
Takagi, D., Sawada, A., & Yamamoto, T. (2017) · Journal of Glaucoma · doi:10.1097/ijg.0000000000000674 · Cited by 76
Feature selection methodology for longitudinal cone-beam CT radiomics
van Timmeren, J. E., Leijenaar, R. T. H., van Elmpt, W., Reymen, B. J. T., & Lambin, P. (2017) · Acta Oncologica · doi:10.1080/0284186x.2017.1350285 · Cited by 83
Meijboom, S., Streppel, M. T., Perenboom, C. W. M., Siebelink, E., van de Wiel, A. M., Geelen, A., Feskens, E. J. M., & de Vries, J. H. M. (2017) · Journal of Nutritional Science · doi:10.1017/jns.2017.45 · Cited by 85
Validity of Queen's College Step Test for estimation of maximum oxygen uptake in female students.
Chatterjee, S., Chatterjee, P., & Bandyopadhyay, A. (2005) · PubMed · Cited by 76
Comparison of computerized methods for detecting the ventilatory thresholds
Santos, E. L., & Giannella‐Neto, A. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1166-6 · Cited by 99
Greenberg, B., Hermann, D. D., Pranulis, M. F., Lazio, L., & Cloutier, D. A. (2000) · Congestive Heart Failure · doi:10.1111/j.1527-5299.2000.80140.x · Cited by 76
Schöning, M., & Scheel, P. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199605000-00020 · Cited by 78
Spry, P. G. D., Spencer, I. C., Sparrow, J. M., Peters, T. J., BROOKES, S. T., Gray, S. F., Baker, I. A., FURBER, J. E., & Easty, D. L. (1999) · British Journal of Ophthalmology · doi:10.1136/bjo.83.6.707 · Cited by 76
Deeg, K. H., & Rupprecht, T. (1989) · Pediatric Radiology · doi:10.1007/bf02387890 · Cited by 76
Canadian hypertension society guidelines for ambulatory blood pressure monitoring
Myers, M. G., Haynes, R. B., & Rabkin, S. W. (1999) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00199-5 · Cited by 86
Andersen, A. E., & DiDomenico, L. (1992) · International Journal of Eating Disorders · doi:10.1002/1098-108x(199204)11:3<283::aid-eat2260110313>3.0.co;2-o · Cited by 339
Reference equation for 6‐min walk distance in healthy North African children 6–16 years old
Saad, H. B., PREFAUT, C. G., Missaoui, R., Mohamed, I. H., Tabka, Z., & Hayot, M. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.20942 · Cited by 88
Sonesson, B., Hansen, F., & Länne, T. (1997) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(97)70185-x · Cited by 76
The validity of body mass index for the assessment of adiposity in children with disease states
Warner, J., Cowan, F. J., Dunstan, F., & Gregory, J. W. (1997) · Annals of Human Biology · doi:10.1080/03014469700004942 · Cited by 76
Maestri, R., Pinna, G. D., Mortara, A., Rovere, M. T. L., & Tavazzi, L. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00499-3 · Cited by 76
Variations in Arterial Blood Pressure and Photoplethysmography During Mechanical Ventilation
Natalini, G., Rosanò, A., Franceschetti, M. E., Facchetti, P., & Bernardini, A. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000202380.22997.24 · Cited by 76
Iohexol clearance for GFR-determination in renal failure--single or multiple plasma sampling?
Sterner, G., Frennby, B., Hultberg, B. L., & Almén, T. (1996) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/11.3.521 · Cited by 76
Simpson, J. A., Lobo, D. N., ANDERSON, J. A., Macdonald, I. A., Perkins, A. C., Neal, K. R., Allison, S. P., & Rowlands, B. J. (2001) · Clinical Nutrition · doi:10.1054/clnu.2001.0398 · Cited by 76
Nolte, F. S., Boysza, J., Thurmond, C., Clark, W. S., & Lennox, J. L. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.3.716-720.1998 · Cited by 76
Comparison of two quantitative hepatitis C virus reverse transcriptase PCR assays
Roth, W. K., Lee, J. H., Rüster, B., & Zeuzem, S. (1996) · Journal of Clinical Microbiology · doi:10.1128/jcm.34.2.261-264.1996 · Cited by 76
Dey, D. K., Bosaeus, I., Lissner, L., & Steen, B. (2003) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601625 · Cited by 75
Use of a Two-Regression Model for Estimating Energy Expenditure in Children
CROUTER, S. E., HORTON, M., & BASSETT, D. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182447825 · Cited by 75
Cameron, J. D., Stevenson, I., Reed, E., McGrath, B. P., Dart, A. M., & Kingwell, B. A. (2004) · Blood Pressure Monitoring · doi:10.1097/00126097-200410000-00007 · Cited by 75
Determination of Skeletal Tumor Burden on 18F-Fluoride PET/CT
ROHREN, E. M., Etchebehere, E., Araujo, J. C., Hobbs, B. P., Swanston, N. M., Everding, M., Moody, T., & Macapinlac, H. A. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.156026 · Cited by 76
Transorbital Sonographic Monitoring of Optic Nerve Diameter in Patients With Severe Brain Injury
Karakitsos, D., Soldatos, T. G., Gouliamos, A., Armaganidis, A., Poularas, J., Kalogeromitros, A., Boletis, J. N., Kostakis, A. G., & Karabinis, A. (2006) · Transplantation Proceedings · doi:10.1016/j.transproceed.2006.10.185 · Cited by 75
von Roth, D., Herkner, H., Schreiber, W., Hubmann, N., Gamper, G., Laggner, A. N., & Havel, C. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.12.024 · Cited by 87
Bendjelid, K., Romand, J.-A., Walder, B., Suter, P. M., & Fournier, G. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.120701 · Cited by 75
Comparison of definitions for the metabolic syndrome in adolescents. The HELENA study
on behalf of the HELENA project group*, Vanlancker, T., Schaubroeck, E., Vyncke, K. E., Cadenas‐Sánchez, C., Breidenassel, C., González‐Gross, M., Gottrand, F., Moreno, L. A., Béghin, L., et al. (2017) · European Journal of Pediatrics · doi:10.1007/s00431-016-2831-6 · Cited by 88
Calibration and Validation of the Youth Activity Profile: The FLASHE Study
Saint‐Maurice, P. F., Kim, Y., Hibbing, P. R., Oh, A., Perna, F. M., & Welk, G. J. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2016.12.010 · Cited by 87
Association Between Optic Nerve Head Deformation and Retinal Microvasculature in High Myopia
Sung, M. S., Lee, T. H., Heo, H., & Park, S. W. (2018) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.01.033 · Cited by 80
Agreement Analysis: What He Said, She Said Versus You Said
Vetter, T. R., & Schober, P. R. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002924 · Cited by 80
Isler, S., Uraz, A., Guler, B., Ozdemir, Y., Cula, S., & Cetiner, D. (2018) · Photomedicine and Laser Surgery · doi:10.1089/pho.2018.4492 · Cited by 63
Accuracy of Self-Reported Height, Weight, and BMI Over Time in Emerging Adults
Lipsky, L. M., Haynie, D. L., Hill, C., Nansel, T. R., Li, K., Liu, D., Iannotti, R. J., & Simons‐Morton, B. G. (2019) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2019.01.004 · Cited by 81
Geerinck, A., Alekna, V., Beaudart, C., Bautmans, I., Cooper, C. C., Orlandi, F. D. S., Konstantynowicz, J., Montero‐Errasquín, B., Topinková, E., Τσεκούρα, Μ., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216065 · Cited by 94
Validity of the Perception Neuron inertial motion capture system for upper body motion analysis
Sers, R., Forrester, S., Moss, E. L., Ward, S., Ma, J., & Zecca, M. (2019) · Measurement · doi:10.1016/j.measurement.2019.107024 · Cited by 89
AAPOS uniform guidelines for instrument-based pediatric vision screen validation 2021
Arnold, R. W., Donahue, S. P., Silbert, D. I., Longmuir, S. Q., Bradford, G. E., Peterseim, M. M. W., Hutchinson, A. K., O’Neil, J. W., Campomanes, A. G. D. A., & Pineles, S. L. (2022) · Journal of American Association for Pediatric Ophthalmology and Strabismus · doi:10.1016/j.jaapos.2021.09.009 · Cited by 75
Shih, A., Robertson, S. A., Vigani, A., da Cunha, A. F., Pablo, L. S., & Bandt, C. (2010) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/j.1476-4431.2010.00536.x · Cited by 84
Gkoltsiou, K., Dimitrakaki, C., Tzavara, C. K., Papaevangelou, V., Varni, J. W., & Tountas, Y. (2007) · Quality of Life Research · doi:10.1007/s11136-007-9294-1 · Cited by 87
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.