STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 5,901–6,000 of 47,868
Cabana, F., Boissy, P., Tousignant, M., Moffet, H., Corriveau, H., & Dumais, R. (2010) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2009.0106 · Cited by 91
Radiographic assessment of the index to ring finger ratio (2D:4D) in adults
Robertson, J., Zhang, W., Liu, J. J., Muir, K. R., Maciewicz, R. A., & Doherty, M. (2007) · Journal of Anatomy · doi:10.1111/j.1469-7580.2007.00830.x · Cited by 77
Bauknecht, H.-C., Romano, V. C., Rogalla, P., Klingebiel, R., Wolf, C., Bornemann, L., Hamm, B., & Hein, P. A. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181c02ed5 · Cited by 77
Dais, P. J., & Spyros, A. (2007) · Magnetic Resonance in Chemistry · doi:10.1002/mrc.1985 · Cited by 77
Carlsen, K. ‐., Engh, C. A., Mørk, M. L., & Schrøder, E. (1998) · Respiratory Medicine · doi:10.1016/s0954-6111(98)90114-7 · Cited by 77
Systematic Review of Screening for Bilirubin Encephalopathy in Neonates
Trikalinos, T. A., Chung, M., Lau, J., & Ip, S. (2009) · PEDIATRICS · doi:10.1542/peds.2008-3545 · Cited by 80
Heart rate measurement in neonatal patients using a webcamera
Scalise, L., Bernacchia, N., Ercoli, I., & Marchionni, P. (2012) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2012.6226654 · Cited by 77
Laidlaw, D. A. H., Tailor, V., Shah, N., Atamian, S., & Harcourt, C. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.121715 · Cited by 79
Lord, P. F., Hansson, K., Carnabuci, C., Kvart, C., & Häggström, J. U. (2011) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2011.00792.x · Cited by 89
A PROMIS fatigue short form for use by individuals who have multiple sclerosis
Cook, K. F., Bamer, A. M., Roddey, T., Kraft, G. H., Kim, J., & Amtmann, D. (2011) · Quality of Life Research · doi:10.1007/s11136-011-0011-8 · Cited by 87
Validation of the Kidney Disease Quality of Life (KDQOL) Cognitive Function subscale
Tamura, M. K., Luan, J., Yaffe, K. S., & Chertow, G. M. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.66024.x · Cited by 77
Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler
Slama, M., Masson, H., Teboul, J., Arnould, M.-L., Nait-Kaoudjt, R., Colas, B., Peltier, M., Tribouilloy, C., Sušić, D., Frohlich, E. D., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2190-z · Cited by 77
Accuracy of computer algorithms and the human eye in scoring actigraphy
Boyne, K. L., Sherry, D. D., Gallagher, P. R., Olsen, M. N., & Brooks, L. J. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0709-z · Cited by 91
A comparative study of pulse rate variability and heart rate variability in healthy subjects
Wong, J.-S., Lu, W.-A., Wu, K.-T., Liu, M., Chen, G.-Y., & Kuo, C. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9340-6 · Cited by 88
Calabrese, E., Zorzi, F., Onali, S., Stasi, E., Fiori, R., Prencipe, S., Bella, A., Petruzziello, C., Condino, G., Lolli, E., et al. (2013) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2013.01.015 · Cited by 77
Corneal topography from spectral optical coherence tomography (sOCT)
Ortiz, S., Siedlecki, D., Pérez‐Merino, P., Chia, N., de Castro, A., Szkulmowski, M., Wojtkowski, M., & Marcos, S. C. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003232 · Cited by 77
Can energy expenditure be predicted in critically ill children?*
Taylor, R. M., Cheeseman, P., Preedy, V. R., Baker, A., & GRIMBLE, G. K. (2003) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000059425.09149.d8 · Cited by 90
Yang, F. B., Lau, T., Lee, E., Vathsala, A., Chia, K. S., & Luo, N. (2014) · The European Journal of Health Economics · doi:10.1007/s10198-014-0664-7 · Cited by 83
Rossi, P., Wanecek, M., Rudehill, A., Konrad, D., Weitzberg, E., & Oldner, A. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215830.48977.29 · Cited by 77
Young, S. P., Stevens, R. D., An, Y., Chen, Y., & Millington, D. S. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(03)00056-3 · Cited by 77
RAFAMANTANANTSOA, H. H., EBINE, N., YOSHIOKA, M., HIGUCHI, H., YOSHITAKE, Y., TANAKA, H., SAITOH, S., & JONES, P. J. H. (2002) · Journal of Nutritional Science and Vitaminology · doi:10.3177/jnsv.48.517 · Cited by 77
Patient-reported Outcomes in Polymyalgia Rheumatica
Matteson, E. L., Kremers, H. M., Cimmino, M. A., Schmidt, W., Schirmer, M., Salvarani, C., Bachta, A., Dejaco, C., Duftner, C., JENSEN, H. S., et al. (2012) · The Journal of Rheumatology · doi:10.3899/jrheum.110977 · Cited by 77
Organization of Myocardial Activation During Ventricular Fibrillation After Myocardial Infarction
Thomas, S. P., Thiagalingam, A., Wallace, E., Kovoor, P., & Ross, D. L. (2005) · Circulation · doi:10.1161/circulationaha.104.503631 · Cited by 77
Are laboratory values in bone marrow aspirate predictable for venous blood in paediatric patients?
Ummenhofer, W. C., Frei, F. J., Urwyler, A., & Drewe, J. (1994) · Resuscitation · doi:10.1016/0300-9572(94)90004-3 · Cited by 77
Thompson, K., MacLaren, D. P., Lees, A., & Atkinson, G. (2004) · Journal of Sports Sciences · doi:10.1080/02640410310001641467 · Cited by 96
Dissociation between running economy and running performance in elite Kenyan distance runners
Mooses, M., Mooses, K., Haile, D. W., Durussel, J., Kaasik, P., & Pitsiladis, Y. P. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.926384 · Cited by 97
Higgins, P. B., Fields, D. A., Hunter, G. R., & Gower, B. A. (2001) · Obesity Research · doi:10.1038/oby.2001.41 · Cited by 77
Relationship between hip strength and frontal plane posture of the knee during a forward lunge
Thijs, Y., Van Tiggelen, D., Willems, T., De Clercq, D., & Witvrouw, E. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.037374 · Cited by 76
Radiographic Abnormalities in the Thoracolumbar Spine of Young Elite Skiers
Rachbauer, F., Sterzinger, W., & Eibl, G. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290041101 · Cited by 77
Ohno, Y., Nishio, M., Koyama, H., Seki, S., Tsubakimoto, M., Fujisawa, Y., Yoshikawa, T., Matsumoto, S., & Sugimura, K. (2014) · Radiology · doi:10.1148/radiol.14132289 · Cited by 77
Knirsch, W., Kretschmar, O., Tomaske, M., Stutz, K., Nagdyman, N., Balmer, C., Schmitz, A., Béttex, D., Berger, F. F., Bauersfeld, U., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1030-y · Cited by 77
Sobngwi, E., Mbanya, J. C. N., Unwin, N. C., Aspray, T. J., & Alberti, K. (2001) · International Journal of Epidemiology · doi:10.1093/ije/30.6.1361 · Cited by 76
Scherhag, A. W., Kaden, J. J., Kentschke, E., Sueselbeck, T., & Borggrefe, M. M. (2005) · Cardiovascular Drugs and Therapy · doi:10.1007/s10557-005-1048-0 · Cited by 77
Velocity and acceleration before contact in the tackle during rugby union matches
Hendricks, S., Karpul, D., Nicolls, F., & Lambert, M. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.707328 · Cited by 95
Roberts, G. C., Newsom, D., Gomez, K., Raffles, A., Saglani, S., Begent, J., Lachman, P., Sloper, K., Buchdahl, R., & Habel, A. (2003) · Thorax · doi:10.1136/thorax.58.4.306 · Cited by 77
Finkelhor, R. S., Lewis, S., & Pillai, D. P. (2014) · Echocardiography · doi:10.1111/echo.12594 · Cited by 77
Distension of the Carotid Artery and Risk of Coronary Events: The Three-City Study
Léone, N., Ducimetière, P., Gariépy, J., Courbon, D., Tzourio, C., Dartigues, J., Ritchie, K. A., Alpérovitch, A., Amouyel, P., Safar, M. E., et al. (2008) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.108.164582 · Cited by 78
Man Versus Machine: Is There an Optimal Method for QT Measurements in Thorough QT Studies?
Darpö, B., Agin, M. A., Kazierad, D. J., Layton, G. R., Muirhead, G. J., Gray, P., & Jorkasky, D. K. (2006) · The Journal of Clinical Pharmacology · doi:10.1177/0091270006286900 · Cited by 86
Ahmed, K. A., McLaren, J. W., Baratz, K. H., Maguire, L. J., Kittleson, K. M., & Patel, S. V. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.05.011 · Cited by 77
Cartilaginous airway wall dimensions and airway resistance in cystic fibrosis lungs
Tiddens, H. A. W. M., Koopman, L. P., Lambert, R. K., Elliott, W. M., Hop, W. C. J., van der Mark, T. W., de Boer, W. J., & de Jongste, J. C. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.15d18.x · Cited by 79
Reproducibility of cervical range of motion in patients with neck pain
Hoving, J. L., Pool, J. J. M., van Mameren, H., Devillé, W. L. J. M., Assendelft, W. J., de Vet, H. C. W., de Winter, A. F., Koes, B. W., & Bouter, L. M. (2005) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-6-59 · Cited by 91
Kronenwett, R., Bohmann, K., Prinzler, J., Sinn, B. V., Haufe, F., Roth, C., Averdick, M., Ropers, T., Windbergs, C., Brase, J. C., et al. (2012) · BMC Cancer · doi:10.1186/1471-2407-12-456 · Cited by 90
Utility of echocardiography in assessment of pulmonary hypertension secondary to COPD
Higham, M. A., Dawson, D. M., Joshi, J., Nihoyannopoulos, P., & Morrell, N. W. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.17303500 · Cited by 77
The validation of a new actigraphy system for the measurement of periodic leg movements in sleep
KING, M., JAFFRE, M., Morrish, E., Shneerson, J. M., & Smith, I. (2005) · Sleep Medicine · doi:10.1016/j.sleep.2004.12.010 · Cited by 77
Lung irradiation induces pulmonary vascular remodelling resembling pulmonary arterial hypertension
Ghobadi, G., Bartelds, B., van der Veen, S. J., Dickinson, M. G., Brandenburg, S., Berger, R. M. F., Langendijk, J. A., Coppes, R. P., & van Luijk, P. (2011) · Thorax · doi:10.1136/thoraxjnl-2011-200346 · Cited by 80
Core Muscle Size Predicts Postoperative Outcome in Lung Transplant Candidates
Weig, T. G., Milger, K., Langhans, B., Janitza, S., Sisic, A., Kenn, K., Irlbeck, T., Pomschar, A., Johnson, T., Irlbeck, M., et al. (2016) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.10.041 · Cited by 82
Tian, L., Ko, M. W. L., Wang, L.-K., Zhang, J.-Y., Li, T.-J., Huang, Y.-F., & Zheng, Y. (2014) · Journal of Refractive Surgery · doi:10.3928/1081597x-20140930-01 · Cited by 80
Edwards, L. J., Pine, K. J., Ellerbrock, I., Weiskopf, N., & Mohammadi, S. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00720 · Cited by 80
McGrath, T. M., Fineman, R. A., & Stirling, L. (2018) · Sensors · doi:10.3390/s18061882 · Cited by 91
Angiography-Derived Fractional Flow Reserve in the SYNTAX II Trial
Asano, T., Katagiri, Y., Chang, C. C., Kogame, N., Chichareon, P., Takahashi, K., Modolo, R., Tenekecioğlu, E., Collet, C. A., Jonker, H., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.09.023 · Cited by 77
Dowling, C., Bavo, A. M., Faquir, N. E., Mortier, P., de Jaegere, P. P. T., Backer, O. D., Søndergaard, L., Ruile, P., Mylotte, D., McConkey, H. Z. R., et al. (2019) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.119.009178 · Cited by 79
Hsu, L., Ingkanisorn, W. P., Kellman, P., Aletras, A. H., & Arai, A. E. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20495 · Cited by 77
Comparison of changes in manifest refraction and corneal power after photorefractive keratectomy
Hugger, P., Kohnen, T., Rosa, F. A. L., Holladay, J. T., & Koch, D. D. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00268-8 · Cited by 77
Role of bioimpedance spectroscopy in assessment of body water compartments in hemodialysis patients
Cox-Reijven, P. L. M., Kooman, J. P., Soeters, P. B., SANDE, F. M. V. D., & Leunissen, K. M. L. (2001) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2001.27703 · Cited by 82
WOJCIECHOWSKA, W., STAESSEN, J. A., NAWROT, T., CWYNAR, M., SEIDLEROVÁ, J., STOLARZ, K., GASOWSKI, J., TICHÁ, M., RICHART, T., THIJS, L., et al. (2006) · Hypertension Research · doi:10.1291/hypres.29.475 · Cited by 76
Rónai, Z., Guttman, A., Nemoda, Z., Staub, M., Kalász, H., & Sasvári‐Székely, M. (2000) · Electrophoresis · doi:10.1002/1522-2683(20000601)21:10<2058::aid-elps2058>3.0.co;2-1 · Cited by 33
Ward, K. A., Adams, J. E., & Hangartner, T. N. (2005) · Calcified Tissue International · doi:10.1007/s00223-005-0031-x · Cited by 77
Accuracy of serial screening for abdominal aortic aneurysms by ultrasound
Wilmink, A. B. M., Forshaw, M. J., Quick, C. R. G., Hubbard, C. S., & Day, N. (2002) · Journal of Medical Screening · doi:10.1136/jms.9.3.125 · Cited by 77
QT dispersion and late potentials during doxorubicin therapy for non‐Hodgkin’s lymphoma
Nousiainen, T., Vanninen, E. J., Rantala, A., Jantunen, E., & Hartikainen, J. E. K. (1999) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.1999.00480.x · Cited by 77
Lantz, C. A., Chen, J., & Buch, D. (1999) · Spine · doi:10.1097/00007632-199906010-00007 · Cited by 77
Maturation of the lower oesophageal sphincter in the preterm baby.
Newell, S. J., Sarkar, P. K., Durbin, G. M., Booth, I. W., & McNeish, A. S. (1988) · Gut · doi:10.1136/gut.29.2.167 · Cited by 77
Odenstedt, H., Stenqvist, O., & Lundin, S. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.460205.x · Cited by 77
Reliability of clinical outcome measures in Charcot-Marie-Tooth disease
Solari, A., Laurá, M., Salsano, E., Radice, D., & Pareyson, D. (2007) · Neuromuscular Disorders · doi:10.1016/j.nmd.2007.09.006 · Cited by 77
Lund, G., Wendland, M. F., Shimakawa, A. S., Arheden, H., Ståhlberg, F., Higgins, C. B., & Saeed, M. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv10487 · Cited by 77
Affordable CD4+ T-cell counts on 'single-platform' flow cytometers I. Primary CD4 gating
Janossy, G., Jani, I. V., & Göhde, W. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02433.x · Cited by 77
Willekes, C., Hoeks, A. P. G., Bots, M. L., Brands, P. J., Willigers, J. M., & Reneman, R. S. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00138-0 · Cited by 77
Beeh, K. M., Beier, J., Kornmann, O., Mander, A., & Buhl, R. (2003) · CHEST Journal · doi:10.1378/chest.123.3.778 · Cited by 86
Objective Accommodation Measurement with the Grand Seiko and Hartinger Coincidence Refractometer
Win-Hall, D. M., Ostrin, L. A., Kasthurirangan, S., & Glasser, A. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181559ace · Cited by 77
Bender, L. E., Spalton, D. J., Uyanonvara, B., Boyce, J. F., Heatley, C. J., Jose, R., & Khan, J. (2004) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2004.05.010 · Cited by 77
Measurement error as a source of QT dispersion: a computerised analysis
Kors, J. A., & van Herpen, G. (1998) · Heart · doi:10.1136/hrt.80.5.453 · Cited by 77
Teschler, H., Farhat, A., Exner, V, Konietzko, N., & Berthon-Jones, M. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10092073 · Cited by 77
Reply: Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
Kaufmann, P. A., & Gaemperli, O. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037457 · Cited by 77
Yoshida, D., Shimada, H., Park, H., Anan, Y., Ito, T., Harada, A., & Suzuki, T. (2014) · Geriatrics & Gerontology International · doi:10.1111/ggi.12177 · Cited by 76
Duncan, M. J., Wunderlich, K., Zhao, Y., & Faulkner, G. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1409855 · Cited by 76
Self-Monitoring of Blood Glucose: The Use of the First or the Second Drop of Blood
Hortensius, J., Slingerland, R. J., Kleefstra, N., Logtenberg, S. J. J., Groenier, K. H., Houweling, S. T., & Bilo, H. J. G. (2011) · Diabetes Care · doi:10.2337/dc10-1694 · Cited by 76
Buelund, L. E., Nielsen, D. H., McEvoy, F. J., Svalastoga, E., & Bjørnvad, C. R. (2010) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.2010.01765.x · Cited by 76
Measuring steps with the Fitbit activity tracker: an inter-device reliability study
Dontje, M. L., de Groot, M., Lengton, R. R., van der Schans, C. P., & Krijnen, W. P. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1050125 · Cited by 75
Analysis of the accuracy of continuous thermodilution cardiac output measurement
Jacquet, L., Hanique, G., Glorieux, D., Matte, P., & Goenen, M. (1996) · Intensive Care Medicine · doi:10.1007/bf01699240 · Cited by 76
Bøyesen, P., McQueen, F. M., Gandjbakhch, F., Lillegraven, S., Coates, L. C., Wiell, C., Haavardsholm, E. A., Conaghan, P. G., PETERFY, C. G., Bird, P., et al. (2011) · The Journal of Rheumatology · doi:10.3899/jrheum.110420 · Cited by 76
Tamarappoo, B. K., Dey, D., Nakazato, R., Shmilovich, H., Smith, T. W., Cheng, V., Thomson, L., Hayes, S. W., Friedman, J. D., Germano, G., et al. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2010.07.011 · Cited by 76
Inter-tester reliability of a self-monitored active knee extension test
Norris, C. M., & Matthews, M. J. (2005) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2005.06.002 · Cited by 76
Glencross, D. K., Coetzee, L. M., Faal, M., Masango, M., Stevens, W. S., Venter, F., & Osih, R. B. (2012) · Journal of the International AIDS Society · doi:10.1186/1758-2652-15-3 · Cited by 80
Berkes, A., Pataki, I., Kiss, M., Kemény, C., Kardos, L., Varni, J. W., & Mogyorósy, G. (2010) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-8-14 · Cited by 89
Duca, L. M., Maahs, D. M., Schauer, I. E., Bergman, B. C., Nadeau, K. J., Bjornstad, P., Rewers, M., & Snell‐Bergeon, J. K. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-3272 · Cited by 80
Heine, M., Verschuren, O. W., Hoogervorst, E. L. J., van Munster, E., Hacking, H. G. A., Visser‐Meily, A., Twisk, J. W. R., Beckerman, H., de Groot, V., Kwakkel, G., et al. (2017) · Multiple Sclerosis Journal · doi:10.1177/1352458517696596 · Cited by 90
Heida, A., Knol, M. H., Kobold, A. C. M., Bootsman, J., Dijkstra, G. D. H., & van Rheenen, P. F. (2017) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2017.06.007 · Cited by 76
Timed Up and Go evaluation with wearable devices: Validation in Parkinson's disease
Kleiner, A. F. R., Pacifici, I., Vagnini, A., Camerota, F., Celletti, C., Stocchi, F., Pandis, M. F. D., & Galli, M. (2017) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2017.07.006 · Cited by 86
Maturational changes of the normal occlusion: A 40-year follow-up
Massaro, C. D. S., Miranda, F., Janson, G., de Almeida, R. R., Pinzan, A., Martins, D. R., & Garib, D. G. (2018) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2017.10.028 · Cited by 90
Establishing Validity and Cross-Context Equivalence of Measures and Indicators
Frongillo, E. A., Baranowski, T., Subar, A. F., Tooze, J. A., & Kirkpatrick, S. I. (2018) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2018.09.005 · Cited by 88
Calvo‐Lobo, C., Almazán-Polo, J., Vallejo, R., Losa‐Iglesias, M. E., Palomo‐López, P., Rodríguez‐Sanz, D., & López‐López, D. (2019) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2019.03.015 · Cited by 84
Reproducibility and validity of an FFQ in the Henan Rural Cohort Study
Xue, Y., Yang, K., Wang, B., Liu, C., Mao, Z., Yu, S., Li, X., Wang, Y., Sun, H., Wang, C., et al. (2019) · Public Health Nutrition · doi:10.1017/s1368980019002416 · Cited by 78
Validity of Using Velocity to Estimate Intensity in Resistance Exercises in Men and Women
Pareja‐Blanco, F., Walker, S., & Häkkinen, K. (2020) · International Journal of Sports Medicine · doi:10.1055/a-1171-2287 · Cited by 95
Hurt, R. T., Ebbert, J. O., Croghan, I. T., Nanda, S., Schroeder, D. R., Teigen, L. M., Velapati, S. R., & Mundi, M. S. (2020) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.1994 · Cited by 88
Evenepoel, C., Clevers, E., Deroover, L., Van Loo, W., Matthys, C., & Verbeke, K. (2020) · Journal of Medical Internet Research · doi:10.2196/18237 · Cited by 69
Weight-bearing CT in foot and ankle pathology
Lintz, F., Beaudet, P., Richardi, G., & Brilhault, J. M. (2020) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2020.102772 · Cited by 76
Das, K. K., Oliveira, T. D. P., & Newell, J. (2023) · Scientific Reports · doi:10.1038/s41598-023-49360-2 · Cited by 112
Abreu, B. C., Seale, G., Scheibel, R. S., Huddleston, N., Zhang, L., & Ottenbacher, K. J. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.9167 · Cited by 80
Haringman, J. J., Vinkenoog, M., Gerlag, D. M., Smeets, T. J. M., Zwinderman, A. H., & Tak, P. P. (2005) · Arthritis Research & Therapy · doi:10.1186/ar1757 · Cited by 89
Plasma Gelsolin is Decreased and Correlates with Rate of Decline in Alzheimer's Disease
Güntert, A., Campbell, J., Saleem, M., O'Brien, D. P., Thompson, A. J., Byers, H. L., Ward, M. A., & Lovestone, S. (2010) · Journal of Alzheimer's Disease · doi:10.3233/jad-2010-100279 · Cited by 74
Yang, Z., Tatham, A. J., Weinreb, R. N., Medeiros, F. A., Liu, T., & Zangwill, L. M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125957 · Cited by 81
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.