The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Optimization of tuned liquid column dampers
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finite Element Procedures in Engineering Analysis
Bathe, K. J., & Saunders, H. (1984) · Journal of Pressure Vessel Technology · doi:10.1115/1.3264375 · Cited by 5,223
Design formulas for tuned mass dampers based on a perturbation technique
Fujino, Y., & Abé, M. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290221002 · Cited by 276
Control of Along‐Wind Response of Structures by Mass and Liquid Dampers
Xu, Y. L., Samali, B., & Kwok, K. C. S. (1992) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1992)118:1(20 · Cited by 189
Self-citationTuned liquid column damper-new type device for suppression of building vibration
SAKAI, F. (1989) · Medical Entomology and Zoology · Cited by 187
Optimum Vibration Absorbers for Linear Damped Systems
Randall, S. E., Halsted, D. M., & Taylor, D. L. (1981) · Journal of Mechanical Design · doi:10.1115/1.3255005 · Cited by 182
Optimum absorber parameters for minimizing vibration response
Warburton, G. B. (1981) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290090306 · Cited by 145
Minimal structural response under random excitation using the vibration absorber
Wirsching, P. H., & Campbell, G. W. (1973) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290020402 · Cited by 120
Xu, Y. L., Kwok, K. C. S., & Samali, B. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90519-g · Cited by 70
Self-citation
Cited by
Tuned liquid column dampers in offshore wind turbines for structural control
Colwell, S., & Basu, B. (2009) · Engineering Structures · doi:10.1016/j.engstruct.2008.09.001 · Cited by 406
Passive structural control of offshore wind turbines
Lackner, M. A., & Rotea, M. A. (2011) · Wind Energy · doi:10.1002/we.426 · Cited by 378
Vibration suppression of structures using tuned mass damper technology: A state-of-the-art review
Yang, F., Sedaghati, R., & Esmailzadeh, E. (2022) · Journal of Vibration and Control · doi:10.1177/1077546320984305 · Cited by 306
Structural control of floating wind turbines
Lackner, M. A., & Rotea, M. A. (2011) · Mechatronics · doi:10.1016/j.mechatronics.2010.11.007 · Cited by 275
Mass dampers and their optimal designs for building vibration control
Chang, C. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00213-7 · Cited by 177
Metadata
- Authors
- Gao, H., Kwok, K. C. S., & Samali, B.
- Venue
- Engineering Structures
- Publisher
- Elsevier BV
- Published
- 1997-06
- Volume
- 19
- Issue
- 6
- Pages
- 476-486
- ISSN
- 0141-0296 (ISSN-L)
- OpenAlex
- W2048914817
- Cited by
- 289
- References
- 8
- FWCI
- 21.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of tuned liquid column dampers. https://app.cochat.ai/papers/10.1016/s0141-0296(96)00099-5
- The paper
- Gao, H., Kwok, K. C. S., & Samali, B. (1997). Optimization of tuned liquid column dampers. Engineering Structures. https://doi.org/10.1016/s0141-0296(96)00099-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.