Hydrolytic degradation of poly(carbonate)-urethanes by monocyte-derived macrophages
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Polycarbonate (PCN)-based polyurethanes (PCNU) are rapidly becoming the chosen polyurethane (PU) for long-term implantation since they have shown decreased susceptibility to oxidation. However, monocyte-derived macrophages (MDM), the cell implicated in biodegradation, also contain hydrolytic activities. Hence, in this study, an activated human MDM cell system was used to assess the biostability of a PCNU, synthesized with 14C-hexane diisocyanate (HDI) and butanediol (BD), previously shown to be susceptible to hydrolysis by cholesterol esterase (CE). Monocytes, isolated from whole blood and cultured for 14 days on polystyrene (PS) to mature MDM, were gently trypsinized and seeded onto 14C-PCNU. Radiolabel release and esterase activity, as measured with p-nitrophenylbutyrate, increased for almost 2 weeks. At 1 week, the increase in radiolabel release and esterase activity were diminished by more than 50% when the protein synthesis inhibitor, cycloheximide, or the serine esterase/protease inhibitor, phenylmethylsulfonylfluoride was added to the medium. This strongly suggests that in part, it was MDM esterase activity which contributed to the PU degradation. In an effort to simulate the potential combination of oxidative and hydrolytic activities of inflammatory cells. 14C-PCNU was exposed to HOCl and then CE. Interestingly, the release of radiolabeled products by CE was significantly inhibited by the pre-treatment of PCNU with HOCl. The results of this study show that while the co-existing roles of oxidation and hydrolysis in the biodegradation of PCNUs remains to be elucidated, a clear relationship is drawn for PCNU degradation to the hydrolytic degradative activities which increase in MDM during differentiation from monocytes, and during activation in the chronic phase of the inflammatory response.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The soft segment of polyether polyurethanes is known to undergo degradation.[86–98]”
From Foreign body reaction to biomaterials (2008) · cites this paper as [90]
In the citing paper
“Otherwise stable biomaterials can exhibit surface degradation and cracking when exposed to the hostile inflammatory environment created by macrophages (Labow et al., 2001; Wiggins et al., 2001), which may cause a breakdown of the implant or the leaching of toxic species into the tissue from the underlying layers.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Labow et al., 2001
In the citing paper
“Studies of this phenomenon by Labow and Santerre have focused on the ability of macrophage-derived enzymes to facilitate degradation of polyurethanes.[90–95]”
From Foreign body reaction to biomaterials (2008) · cites this paper as [90]
Citations
Cites
Isolation of mononuclear cells and granulocytes from human blood.
Bøyum, A. (1968) · Scandinavian Journal of Clinical and Laboratory Investigation · Cited by 9,585
A simple, rapid, and sensitive DNA assay procedure
Labarca, C., & Paigen, K. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90165-7 · Cited by 4,901
Chlorination of Taurine by Human Neutrophils
Weiss, S. J., Klein, R., Slivka, A., & Wei, M. (1982) · Journal of Clinical Investigation · doi:10.1172/jci110652 · Cited by 805
Polyurethane Elastomer Biostability
Stokes, K., McVenes, R., & Anderson, J. M. (1995) · Journal of Biomaterials Applications · doi:10.1177/088532829500900402 · Cited by 366
Chapter 4 Mechanisms of inflammation and infection with implanted devices
Anderson, J. M. (1993) · Cardiovascular Pathology · doi:10.1016/1054-8807(93)90045-4 · Cited by 331
Pinchuk, L. (1995) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856294x00347 · Cited by 252
Biodegradation evaluation of polyether and polyester‐urethanes with oxidative and hydrolytic enzymes
Santerre, J. P., Labow, R. S., Duguay, D. G., Erfle, D., & Adams, G. A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281009 · Cited by 191
Self-citationLinhart, W., Peters, F., Lehmann, W., Schwarz, K., Schilling, A. F., Amling, M., Rueger, J. M., & Epple, M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200102)54:2<162::aid-jbm2>3.0.co;2-3 · Cited by 181
Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80A
Zhao, Q., Agger, M. P., Fitzpatrick, M. N., Anderson, J. M., Hiltner, A., Stokes, K., & Urbanski, P. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240508 · Cited by 158
Degradation of biomaterials by phagocyte-derived oxidants.
Sutherland, K., Mahoney, J. R., Coury, A. J., & Eaton, J. W. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116841 · Cited by 144
Research works printed but not linked: 2
- Wang, 1997, Biodegradation of a poly(ester-urea-urethane) by cholesterol esterase, J Biomed Mater Res, 35, 207
- Shin, 1999, Histology and electron microscopy of explanted bifurcated endovascular aortic grafts, J Endovasc Surg, 6, 246, 10.1583/1074-6218(1999)006 · doi:10.1583/1074-6218(1999)006
Cited by
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
Santerre, J. P., Woodhouse, K., Laroche, G., & Labow, R. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.079 · Cited by 718
Self-citationMacrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“When an implant is present, these mechanical challenges can lead to nerve trauma, exacerbating FBR—particularly when stiff implant materials, contrasting with the very soft nerve tissue, are present (Lacour et al., 2016).”
BackgroundInfluential
Metadata
- Authors
- Labow, R. S., Meek, E., & Santerre, J. P.
- Affiliations
- Ottawa Heart Institute (CA)
- University of Toronto (CA)
- Corresponding author
- Labow, R.S
- ORCID
- Santerre, J.P
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2001-11
- Volume
- 22
- Issue
- 22
- Pages
- 3025-3033
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2077012531
- Cited by
- 108
- References
- 34
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2023: 2 · 2022: 5 · 2021: 3 · 2020: 1 · 2019: 3 · 2018: 3 · 2017: 6 · 2016: 6 · 2015: 5 · 2014: 4 · 2013: 3 · 2012: 3
- FWCI
- 2.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Ottawa
- Canadian Institutes of Health Research
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Keywords
- polycarbonate urethane, hydrolytic degradation, monocyte-derived macrophages, biodegradation, cholesterol esterase, esterase activity, chronic inflammation, biostability, cycloheximide, phenylmethylsulfonyl fluoride, long-term implants
- MeSH terms
- Biocompatible Materials, Biodegradation, Environmental, Cells, Cultured, Humans, Hydrolysis, Macrophages, Materials Testing, Microscopy, Electron, Scanning, Monocytes, Oxidation-Reduction, Polymers, Polyurethanes, Surface Properties
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrolytic degradation of poly(carbonate)-urethanes by monocyte-derived macrophages. https://app.cochat.ai/papers/10.1016/s0142-9612(01)00049-7
- The paper
- Labow, R. S., Meek, E., & Santerre, J. P. (2001). Hydrolytic degradation of poly(carbonate)-urethanes by monocyte-derived macrophages. Biomaterials. https://doi.org/10.1016/s0142-9612(01)00049-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.