Polyurethane Elastomer Biostability
Abstract
Polyurethanes have unique mechanical and biologic properties that make them ideal for many implantable devices. They are subject to some in vivo degradation mechanisms, however. Polyester polyurethanes are subject to hydrolytic degradation and are no longer used in long-term implanted devices. Polyether polyurethanes, while hydrolytically stable, are subject to oxidative degradation in several forms, including environmental stress cracking and metal ion oxidation. Mineralization is also known to occur. A new polycarbonate polyurethane has superior biostability in early in vivo qualification tests compared to the polyether polyurethanes, including no evidence of hydrolysis, ESC or MIO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
CRC Handbook of Chemistry and Physics
P, D. (1992) · Journal of Molecular Structure · doi:10.1016/0022-2860(92)85083-s · Cited by 9,329
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Macrophages and Polymorphonuclear Neutrophils in Lung Defense and Injury
Sibille, Y., & Reynolds, H. Y. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.471 · Cited by 1,083
Photodegradation, photo-oxidation and photostabilization of polymers
J.F.McK. (1976) · Journal of Molecular Structure · doi:10.1016/0022-2860(76)80158-5 · Cited by 735
Inflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Self-citationPeppas, N. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90038-x · Cited by 371
Bonart, R. C. (1968) · Journal of Macromolecular Science Part B · doi:10.1080/00222346808212867 · Cited by 363
Lelah, M. D., & Cooper, S. L. (1986) · Medical Entomology and Zoology · Cited by 348
Cited by
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
Santerre, J. P., Woodhouse, K., Laroche, G., & Labow, R. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.079 · Cited by 718
Photopolymerizable Biomaterials and Light-Based 3D Printing Strategies for Biomedical Applications
Yu, C., Schimelman, J., Wang, P., Miller, K. L., Ma, X., You, S., Guan, J., Sun, B., Zhu, W., & Chen, S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00810 · Cited by 579
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Brannigan, R. P., & Dove, A. P. (2017) · Biomaterials Science · doi:10.1039/c6bm00584e · Cited by 334
Metadata
- Authors
- Stokes, K., McVenes, R., & Anderson, J. M.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 9
- Issue
- 4
- Pages
- 321-354
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W1598825449
- Cited by
- 366
- References
- 43
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyurethane Elastomer Biostability. https://app.cochat.ai/papers/10.1177/088532829500900402
- The paper
- Stokes, K., McVenes, R., & Anderson, J. M. (1995). Polyurethane Elastomer Biostability. Journal of Biomaterials Applications. https://doi.org/10.1177/088532829500900402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.