The nature of backbone monomers determines the performance of imprinted soft contact lenses as timolol drug delivery systems
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wulff, G. (1995) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199518121 · Cited by 2,373 · cited 1×
“Molecular recognition in biological and biomimetic systems takes places by the combination of several complementary weak interactions between the binding site and the molecule to be bound [11].”
BackgroundAnalytical profiles of drug substances
(1975) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600640947 · Cited by 1,491
Soft contact lens polymers: an evolution
Nicolson, P. C., & Vogt, J. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00165-x · Cited by 747 · cited 1×
“The knowledge of the repercussion of all these effects on the performance of an imprinted system becomes particularly important in the case of soft contact lenses, the main composition of which is restricted to some approved monomers that differ in oxygen permeability, water affinity and hydrogen-bonding capacity and…”
BackgroundThe Emerging Technique of Molecular Imprinting and Its Future Impact on Biotechnology
Mosbach, K., & Ramström, O. (1996) · Nature Biotechnology · doi:10.1038/nbt0296-163 · Cited by 723 · cited 1×
“Molecular imprinting technology, as first developed by Wulff, Mosbach and co-workers, involves polymerization of functional monomers in the presence of template molecules and requires a large amount of cross-linker (50mol%) and a solvent [10].”
MethodHydrogels: Swelling, Drug Loading, and Release
Kim, S. W., Bae, Y. H., & Okano, T. (1992) · Pharmaceutical Research · doi:10.1023/a:1015887213431 · Cited by 656 · cited 1×
“Depending on the copolymer composition, the thickness of the sample and the amount of drug loaded, different kinetics have been reported for swelling and drug release from HEMA hydrogels [18,23].”
BackgroundTopical Ocular Drug Delivery: Recent Developments and Future Challenges
LEE, V. H. L., & ROBINSON, J. R. (1986) · Journal of Ocular Pharmacology and Therapeutics · doi:10.1089/jop.1986.2.67 · Cited by 503 · cited 1×
“Conventional ophthalmic formulations generally show low bioavailability because of the ocular protective mechanisms, such as tear drainage and blinking [1,2].”
BackgroundKarlgard, C., Wong, N. S.-W., Jones, L., & Moresoli, C. (2003) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(03)00124-8 · Cited by 271
Hiratani, H., & Alvarez-Lorenzo, C. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00213-4 · Cited by 235 · cited 3×
“In previous studies, we observed that the application of the molecular imprinting technology in the design of soft contact lenses strongly increases the amount of drug loaded [8,9].”
BackgroundMethodSelf-citationEichenbaum, G. M., Kiser, P. F., Dobrynin, A. V., Simon, S. A., & Needham, D. (1999) · Macromolecules · doi:10.1021/ma981945s · Cited by 229
Soft Contact Lenses Capable of Sustained Delivery of Timolol
Alvarez-Lorenzo, C., Hiratani, H., Gómez-Amoza, J. L., Martínez‐Pacheco, R., Souto, C., & Concheiro, A. (2002) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10209 · Cited by 229 · cited 6×
“Although without MAAmers, HEMA only lenses do not significantly load this drug [8], the presence of HEMA around the MAA-mers may contribute to create an adequate microenvironment to enhance the interactions with timolol, chiefly in the imprinted systems [14].”
BackgroundSelf-citationSolute and penetrant diffusion in swellable polymers. IV.
Ségot-Chicq, S., & Peppas, N. A. (1986) · Journal of Controlled Release · doi:10.1016/0168-3659(86)90080-5 · Cited by 228
Korsmeyer, R. W., & Peppas, N. A. (1984) · Journal of Controlled Release · doi:10.1016/0168-3659(84)90001-4 · Cited by 219
Recent developments in ophthalmic drug delivery
Ding, S. (1998) · Pharmaceutical Science & Technology Today · doi:10.1016/s1461-5347(98)00087-x · Cited by 207 · cited 1×
“Conventional ophthalmic formulations generally show low bioavailability because of the ocular protective mechanisms, such as tear drainage and blinking [1,2].”
BackgroundRieger, J. (2001) · Polymer Testing · doi:10.1016/s0142-9418(00)00023-4 · Cited by 203 · cited 1×
“These differences, which are commonly reported when these techniques are applied to the same material, may be attributed to the different physical property recorded and to the greater size of the sample required for the mechanical analyses [25].”
BackgroundTwenty-five Years of Contact Lenses: The Impact on the Cornea and Ophthalmic Practice
McMahon, T. T., & Zadnik, K. (2000) · Cornea · doi:10.1097/00003226-200009000-00018 · Cited by 138
Drug delivery through soft contact lenses.
Jain, M. R. (1988) · British Journal of Ophthalmology · doi:10.1136/bjo.72.2.150 · Cited by 122 · cited 1×
“to improve corneal penetration and bioavailability of ocular drugs [3], in most cases the low drug loading capacity and the fact that a significant fraction of the drug taken up may be irreversibly bound to the lenses limit, to some extent, their therapeutical utility [6,7].”
BackgroundPoly(methyl acrylate‐co‐hydroxyethyl acrylate) hydrogel implant material of strength and softness
Refojo, M. F., & Leong, F. (1981) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820150406 · Cited by 63
Cai, W. S., Gan, L. H., & Tam, K. C. (2001) · Colloid & Polymer Science · doi:10.1007/s003960100506 · Cited by 33 · cited 1×
“The broadness of the transition region may be caused by the presence of hydrophilic MAA moieties [28].”
BackgroundBioerodible hydrogels based on 2‐hydroxyethyl methacrylate: Synthesis and characterization
Chiellini, E., Petrucci, F., Ranucci, E., & Solaro, R. (2002) · Journal of Applied Polymer Science · doi:10.1002/app.10799 · Cited by 21 · cited 1×
“Tg of the HEMA-based lens was similar to the values found in the literature [24].”
Result
Cited by
Polymers for Drug Delivery Systems
Liechty, W. B., Kryscio, D. R., Slaughter, B. V., & Peppas, N. A. (2010) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-073009-100847 · Cited by 1,608
Whitcombe, M. J., Kirsch, N., & Nicholls, I. A. (2014) · Journal of Molecular Recognition · doi:10.1002/jmr.2347 · Cited by 445
Molecularly imprinted polymers for drug delivery
Alvarez-Lorenzo, C., & Concheiro, A. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2003.12.032 · Cited by 387
Self-citationPolymeric hydrogels for novel contact lens-based ophthalmic drug delivery systems: A review
Xinming, L., Yingde, C., Lloyd, A. W., Mikhalovsky, S. V., Sandeman, S. R., Howel, C. A., & Liewen, L. (2008) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2007.09.002 · Cited by 306
Ocular release of timolol from molecularly imprinted soft contact lenses
Hiratani, H., Fujiwara, A., Tamiya, Y., Mizutani, Y., & Alvarez-Lorenzo, C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.030 · Cited by 285
Self-citation
Metadata
- Authors
- Hiratani, H., & Alvarez-Lorenzo, C.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 25
- Issue
- 6
- Pages
- 1105-1113
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2007185684
- Cited by
- 178
- References
- 19
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.