Calcium phosphate ceramic coatings as carriers of vancomycin
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Infection in the setting of total joint arthroplasty remains a challenging problem. Attention has turned to developing methods of local delivery of antibiotics for prophylaxis. Vancomycin loaded into calcium phosphate ceramic coatings on titanium alloy substrates is a clinically relevant concept in the setting of total joint arthroplasty. Drug loading was accomplished by immersion of ceramic-coated discs in vancomycin-containing simulated physiological solution; in some experiments drug loading by immersion was followed by lipid coating in egg phosphatidylcholine solutions. The kinetics of vancomycin release and the efficacy of drug inhibition of Staphylococcus aureus were determined in vitro in comparison to the release from currently used antibiotic-laden poly(methyl methacrylate) (PMMA). The loading by immersion provided effective release and inhibition at early time points (up to 24 h); however, the lipid-coated samples demonstrated significant release and effective bacterial inhibition up to 72 h. The two-step procedure, i.e. drug loading followed by lipid coating in order to slow antibiotic elution, is more effective than the conventional one-step loading. The study indicated that the osteoconductive calcium phosphate coatings have the potential to serve as drug carriers to prevent infection in the setting of total joint arthroplasty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antibiotics in Laboratory Medicine.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-4-653_4 · Cited by 2,779
Antibiotics in Laboratory Medicine
White, W. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03480090121040 · Cited by 669
Radin, S. R., & Ducheyne, P. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270106 · Cited by 521
Self-citationDucheyne, P., Radin, S., & King, L. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270105 · Cited by 467
Self-citationCalcium hydroxyapatite ceramic used as a delivery system for antibiotics
Shinto, Y., Uchida, A., Korkusuz, F., Araki, N., & Ono, K. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b4.1320622 · Cited by 302
Antibiotic-loaded acrylic cement: current concepts.
Hw, B., Elson, R. A., & Heinert, K. (1984) · PubMed · Cited by 288
Vancomycin Penetration Into Biofilm Covering Infected Prostheses And Effect On Bacteria
Darouiche, R. O., Dhir, A., Miller, A. J., Landon, G. C., Raad, I. I., & Musher, D. M. (1994) · Journal of Infectious Diseases · doi:10.1093/infdis/170.3.720 · Cited by 220
Antibiotic-loaded Acrylic Cement: Current Concepts
BUCHHOLZ, H. W., ELSON, R. A., & HEINERT, K. (1984) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198411000-00014 · Cited by 218
Bioactive Ceramic Prosthetic Coatings
Ducheyne, P., & Cuckler, J. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199203000-00014 · Cited by 218
Self-citationEffect of calcium phosphate coating characteristics on early post-operative bone tissue ingrowth
Duheyne, P., Beight, J., Cuckler, J. M., Evans, B., & Radin, S. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90073-y · Cited by 169
Self-citation
Cited by
Normal Bone Anatomy and Physiology
Clarke, B. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04151206 · Cited by 2,192
The significance of infection related to orthopedic devices and issues of antibiotic resistance
Campoccia, D., Montanaro, L., & Arciola, C. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.044 · Cited by 1,109
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Bose, S., & Tarafder, S. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.017 · Cited by 958
Antibacterial coatings on titanium implants
Zhao, L., Chu, P. K., Zhang, Y., & Wu, Z. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31463 · Cited by 866
Biodegradable Materials for Bone Repair and Tissue Engineering Applications
Sheikh, Z., Najeeb, S., Khurshid, Z., Verma, V., Rashid, H., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095273 · Cited by 782
The future of biologic coatings for orthopaedic implants
Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.074 · Cited by 779
Paital, S. R., & Dahotre, N. B. (2009) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2009.05.001 · Cited by 673
Stigter, M., Bezemer, J., de Groot, K., & Layrolle, P. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.06.011 · Cited by 446
Altınoǧlu, E. I., Russin, T. J., Kaiser, J. M., Barth, B. M., Eklund, P. C., Kester, M., & Adair, J. H. (2008) · ACS Nano · doi:10.1021/nn800448r · Cited by 430
Simchi, A., Tamjid, E., Pishbin, F., & Boccaccini, A. R. (2011) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2010.10.005 · Cited by 404
Kazemzadeh-Narbat, M., Kindrachuk, J., Duan, K., Jenssen, H., Hancock, R. E. W., & Wang, R. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.035 · Cited by 343
Titanium Coatings and Surface Modifications: Toward Clinically Useful Bioactive Implants
Civantos, A., Martínez-Campos, E., Ramos, V., Elvira, C., Gallardo, A., & Abarrategi, A. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00604 · Cited by 338
Bioinspired surface modification of orthopedic implants for bone tissue engineering
Hu, C., Ashok, D., Nisbet, D. R., & Gautam, V. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119366 · Cited by 324
Multifunctional Coatings and Nanotopographies: Toward Cell Instructive and Antibacterial Implants
Mas‐Moruno, C., Su, B., & Dalby, M. J. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801103 · Cited by 242
Incorporation of tobramycin into biomimetic hydroxyapatite coating on titanium
Stigter, M., de Groot, K., & Layrolle, P. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00157-6 · Cited by 237
Kirmanidou, Y., Sidira, M., Drosou, M.-E., Bennani, V., Bakopoulou, A., Tsouknidas, A., Michailidis, N., & Michalakis, K. (2016) · BioMed Research International · doi:10.1155/2016/2908570 · Cited by 231
Chen, W., Oh, S., Ong, A. P., Oh, N., Liu, Y., Courtney, H. S., Appleford, M., & Ong, J. L. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31197 · Cited by 206
Tarafder, S., & Bose, S. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501048n · Cited by 204
Fighting bacterial infections—Future treatment options
Fernebro, J. (2011) · Drug Resistance Updates · doi:10.1016/j.drup.2011.02.001 · Cited by 199
Besinis, A., Hadi, S. D., Le, H. R., Tredwin, C., & Handy, R. D. (2017) · Nanotoxicology · doi:10.1080/17435390.2017.1299890 · Cited by 192
“However, such approaches usually suffer from short-term antimicrobial efficacy (Radin et al., 1997), whereas the use of chlorhexidine has also been reported to have a cytotoxic effect on human cells (Lessa et al., 2010; Pucher & Daniel, 1992).”
BackgroundAlt, V., Bitschnau, A., Österling, J., Sewing, A., Meyer, C., Kraus, R., Meissner, S. A., Wenisch, S., Domann, E., & Schnettler, R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.035 · Cited by 180
Joosten, U., Joist, A., Gosheger, G., Liljenqvist, U., Brandt, B., & von Eiff, C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.001 · Cited by 172
Surface modifications of bone implants through wet chemistry
Duan, K., & Wang, R. (2006) · Journal of Materials Chemistry · doi:10.1039/b517634d · Cited by 169
Metadata
- Authors
- Radin, S., Campbell, J. T., Ducheyne, P., & Cuckler, J. M.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1997-06
- Volume
- 18
- Issue
- 11
- Pages
- 777-782
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1987156394
- Cited by
- 188
- References
- 20
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.