The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The future of biologic coatings for orthopaedic implants
Open accessAbstract
Implants are widely used for othopaedic applications such as fixing fractures, repairing nonunions, obtaining a joint arthrodesis, total joint arthroplasty, spinal reconstruction, and soft tissue anchorage. Previously, orthopaedic implants were designed simply as mechanical devices; the biological aspects of the implant were a byproduct of stable internal/external fixation of the device to the surrounding bone or soft tissue. More recently, biologic coatings have been incorporated into orthopaedic implants in order to modulate the surrounding biological environment. This opinion article reviews current and potential future use of biologic coatings for orthopaedic implants to facilitate osseointegration and mitigate possible adverse tissue responses including the foreign body reaction and implant infection. While many of these coatings are still in the preclinical testing stage, bioengineers, material scientists and surgeons continue to explore surface coatings as a means of improving clinical outcome of patients undergoing orthopaedic surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“Insertion of an implant of any type within the body including bone evokes an inflammatory and (usually) limited foreign body reaction [56].”
Background
Cited by
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Fernandes, H. R., Gaddam, A., Rebelo, A., Brazete, D., Stan, G. E., & Ferreira, J. M. F. (2018) · Materials · doi:10.3390/ma11122530 · Cited by 397
The Influence of Surface Modification on Bacterial Adhesion to Titanium-Based Substrates
Lorenzetti, M., Dogša, I., Stošicki, T., Stopar, D., Kalin, M., Kobe, S., & Novak, S. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/am507148n · Cited by 365
Current status and prospects of metal-organic frameworks for bone therapy and bone repair
Li, M., Yin, S., Lin, M., Chen, X., Pan, Y., Peng, Y., Sun, J., Kumar, A., & Liu, J. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb00742h · Cited by 156
Chen, J., Zhang, X., Huang, C., Cai, H., Hu, S., Wan, Q., Pei, X., & Wang, J. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35960 · Cited by 150
Metadata
- Authors
- Goodman, S. B., Yao, Z., Keeney, M., & Yang, F.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2013-04
- Volume
- 34
- Issue
- 13
- Pages
- 3174-3183
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2128672939
- Cited by
- 779
- References
- 1
- FWCI
- 35.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The future of biologic coatings for orthopaedic implants. https://app.cochat.ai/papers/10.1016/j.biomaterials.2013.01.074
- The paper
- Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013). The future of biologic coatings for orthopaedic implants. Biomaterials. https://doi.org/10.1016/j.biomaterials.2013.01.074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.