Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 964

The DOI matches its Crossref record.

Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85

Open access
Valentin, J.·2000·Annals of the ICRP

Abstract

Interventional radiology (fluoroscopically-guided) techniques are being used by an increasing number of clinicians not adequately trained in radiation safety or radiobiology. Many of these interventionists are not aware of the potential for injury from these procedures or the simple methods for decreasing their incidence. Many patients are not being counselled on the radiation risks, nor followed up when radiation doses from difficult procedures may lead to injury. Some patients are suffering radiation-induced skin injuries and younger patients may face an increased risk of future cancer. Interventionists are having their practice limited or suffering injury, and are exposing their staff to high doses. In some interventional procedures, skin doses to patients approach those experienced in some cancer radiotherapy fractions. Radiation-induced skin injuries are occurring in patients due to the use of inappropriate equipment and, more often, poor operational technique. Injuries to physicians and staff performing interventional procedures have also been observed. Acute radiation doses (to patients) may cause erythema at 2 Gy, cataract at 2 Gy, permanent epilation at 7 Gy, and delayed skin necrosis at 12 Gy. Protracted (occupational) exposures to the eye may cause cataract at 4 Gy if the dose is received in less than 3 months, at 5.5 Gy if received over a period exceeding 3 months. Practical actions to control dose to the patient and to the staff are listed. The absorbed dose to the patient in the area of skin that receives the maximum dose is of priority concern. Each local clinical protocol should include, for each type of interventional procedure, a statement on the cumulative skin doses and skin sites associated with the various parts of the procedure. Interventionists should be trained to use information on skin dose and on practical techniques to control dose. Maximum cumulative absorbed doses that appear to approach or exceed 1 Gy (for procedures that may be repeated) or 3 Gy (for any procedure) should be recorded in the patient record, and there should be a patient follow-up procedure for such cases. Patients should be counselled if there is a significant risk of radiation-induced injury, and the patient's personal physician should be informed of the possibility of radiation effects. Training in radiological protection for patients and staff should be an integral part of the education for those using interventional techniques. All interventionists should audit and review the outcomes of their procedures for radiation injury. Risks and benefits, including radiation risks, should be taken into account when new interventional techniques are introduced. A concluding list of recommendations is given. Annexes list procedures, patient and staff doses, a sample local clinical protocol, dose quantities used, and a procurement checklist.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0146-6453(01)00004-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 964

Metadata

Authors
Valentin, J.
Venue
Annals of the ICRP
Published
2000-06
Volume
30
Issue
2
Pages
7-7
ISSN
  • 0146-6453 (ISSN-L)
  • 1872-969X
OpenAlex
W1912970349
Cited by
964
References
0
Type
conference abstract
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85. https://app.cochat.ai/papers/10.1016/s0146-6453(01)00004-5
The paper
Valentin, J. (2000). Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85. Annals of the ICRP. https://doi.org/10.1016/s0146-6453(01)00004-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.