Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85
Open accessThe DOI matches its Crossref record.
Abstract
Interventional radiology (fluoroscopically-guided) techniques are being used by an increasing number of clinicians not adequately trained in radiation safety or radiobiology. Many of these interventionists are not aware of the potential for injury from these procedures or the simple methods for decreasing their incidence. Many patients are not being counselled on the radiation risks, nor followed up when radiation doses from difficult procedures may lead to injury. Some patients are suffering radiation-induced skin injuries and younger patients may face an increased risk of future cancer. Interventionists are having their practice limited or suffering injury, and are exposing their staff to high doses. In some interventional procedures, skin doses to patients approach those experienced in some cancer radiotherapy fractions. Radiation-induced skin injuries are occurring in patients due to the use of inappropriate equipment and, more often, poor operational technique. Injuries to physicians and staff performing interventional procedures have also been observed. Acute radiation doses (to patients) may cause erythema at 2 Gy, cataract at 2 Gy, permanent epilation at 7 Gy, and delayed skin necrosis at 12 Gy. Protracted (occupational) exposures to the eye may cause cataract at 4 Gy if the dose is received in less than 3 months, at 5.5 Gy if received over a period exceeding 3 months. Practical actions to control dose to the patient and to the staff are listed. The absorbed dose to the patient in the area of skin that receives the maximum dose is of priority concern. Each local clinical protocol should include, for each type of interventional procedure, a statement on the cumulative skin doses and skin sites associated with the various parts of the procedure. Interventionists should be trained to use information on skin dose and on practical techniques to control dose. Maximum cumulative absorbed doses that appear to approach or exceed 1 Gy (for procedures that may be repeated) or 3 Gy (for any procedure) should be recorded in the patient record, and there should be a patient follow-up procedure for such cases. Patients should be counselled if there is a significant risk of radiation-induced injury, and the patient's personal physician should be informed of the possibility of radiation effects. Training in radiological protection for patients and staff should be an integral part of the education for those using interventional techniques. All interventionists should audit and review the outcomes of their procedures for radiation injury. Risks and benefits, including radiation risks, should be taken into account when new interventional techniques are introduced. A concluding list of recommendations is given. Annexes list procedures, patient and staff doses, a sample local clinical protocol, dose quantities used, and a procurement checklist.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abbara, S., Blanke, P., Maroules, C. D., Cheezum, M., Choi, A. D., Han, B. K., Marwan, M., Naoum, C., Norgaard, B. L., Rubinshtein, R., et al. (2016) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2016.10.002 · Cited by 1,095
American College of Radiology White Paper on Radiation Dose in Medicine
Amis, E. S., Butler, P. F., Applegate, K. E., Birnbaum, S. B., Brateman, L. F., Hevezi, J. M., Mettler, F. A., Morin, R. L., Pentecost, M. J., Smith, G. G., et al. (2007) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.03.002 · Cited by 902
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Balter, S., Hopewell, J. W., Miller, D. L., Wagner, L. K., & Zelefsky, M. J. (2010) · Radiology · doi:10.1148/radiol.2542082312 · Cited by 600
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
ICRP Publication 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology
Khong, P.-L., Ringertz, H., Donoghue, V., Frush, D., Rehani, M., Appelgate, K., & Sanchez, R. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.10.001 · Cited by 363
Venneri, L., Rossi, F., Botto, N., Andreassi, M. G., Salcone, N., Emad, A., Lazzeri, M., Gori, C., Vano, E., & Picano, E. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.08.009 · Cited by 360
Radiation Cataract Risk in Interventional Cardiology Personnel
Vano, E., Kleiman, N. J., Duran, A., Rehani, M. M., Echeverri, D., & Cabrera, M. (2010) · Radiation Research · doi:10.1667/rr2207.1 · Cited by 360
Ciraj‐Bjelac, O., Rehani, M. M., Sim, K. H., Liew, H. B., Vano, E., & Kleiman, N. J. (2010) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22670 · Cited by 330
Heidbuchel, H., Wittkampf, F. H. M., Vano, E., Ernst, S., Schilling, R., Picano, E., Mont, L., ESC Scientific Document Group, Jais, P., de Bono, J., et al. (2014) · EP Europace · doi:10.1093/europace/eut409 · Cited by 311
Radiation safety program for the cardiac catheterization laboratory
E. Chambers, C., A. Fetterly, K., Holzer, R., Paul Lin, P., C. Blankenship, J., Balter, S., & K. Laskey, W. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22867 · Cited by 301
ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures
López, P. O., Dauer, L. T., Loose, R., Martin, C. J., Miller, D. L., Vañó, E., Doruff, M., Padovani, R., Massera, G., & Yoder, C. (2018) · Annals of the ICRP · doi:10.1177/0146645317750356 · Cited by 276
Vano, E., Kleiman, N. J., Duran, A., Romano-Miller, M., & Rehani, M. M. (2013) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2012.10.016 · Cited by 268
Coles, D. R., Smail, M. A., Negus, I. S., Wilde, P., Oberhoff, M., Karsch, K. R., & Baumbach, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.078 · Cited by 265
Eye Lens Exposure to Radiation in Interventional Suites: Caution Is Warranted
Vano, E., Gonzalez, L., Fernández, J. M., & Haskal, Z. J. (2008) · Radiology · doi:10.1148/radiol.2482071800 · Cited by 263
Exposing the Thyroid to Radiation: A Review of Its Current Extent, Risks, and Implications
Sinnott, B., Ron, E., & Schneider, A. B. (2010) · Endocrine Reviews · doi:10.1210/er.2010-0003 · Cited by 246
Bashore, T. M., Balter, S., Barac, A., Byrne, J. G., Cavendish, J. J., Chambers, C. E., Hermiller, J. B., Kinlay, S., Landzberg, J. S., Laskey, W. K., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.02.010 · Cited by 220
Occupational eye dose in interventional cardiology procedures
Haga, Y., Chida, K., Kaga, Y., Sota, M., Meguro, T., & Zuguchi, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-00556-3 · Cited by 189
Kalra, M. K., Woisetschläger, M., Dahlström, N., Singh, S., Lindblom, M., Choy, G., Quick, P., Schmidt, B., Sedlmair, M., Blake, M. A., et al. (2012) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e31825586c0 · Cited by 168
Preliminary reference levels in interventional cardiology
Neofotistou, V., Vano, E., Padovani, R., Kotre, J., Dowling, A., Toivonen, M., Kottou, S., Tsapaki, V., Willis, S., Bernardi, G., et al. (2003) · European Radiology · doi:10.1007/s00330-003-1831-x · Cited by 159
Hoang, J. K., Wang, C., Frush, D. P., Enterline, D. S., Samei, E., Toncheva, G., Lowry, C., & Yoshizumi, T. T. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.10031 · Cited by 37
Metadata
- Authors
- Valentin, J.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2000-06
- Volume
- 30
- Issue
- 2
- Pages
- 7-7
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W1912970349
- Cited by
- 964
- References
- 0
- Type
- conference abstract
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.