Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record.

Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery

Open access
Reinstein, Dan Z., Silverman, Ronald H., Sutton, Hugo F.S., Coleman, D.Jackson·1999·Ophthalmology

Abstract

OBJECTIVE: To examine the utility of very high-frequency (VHF) ultrasound scanning in determining the anatomic changes and correlates of optical complications in lamellar refractive surgery. STUDY DESIGN: Case series. PARTICIPANTS: Cases analyzed included marked asymmetric astigmatism postautomated lamellar keratoplasty (ALK), image ghosting despite normal videokeratography post-ALK, uncomplicated myopic laser in situ keratomileusis (LASIK), and hyperopic LASIK with regression. METHODS: A prototype VHF ultrasound scanner (50 MHz) was used to obtain sequences of parallel B-scans of the cornea. Digital signal processing techniques were used to measure epithelial, stromal, and flap thickness values in a grid encompassing the central 4 to 5 mm of the cornea, enabling pachymetric mapping of each layer with 2-micron precision. MAIN OUTCOME MEASURE: The appearance of the corneas in VHF ultrasound images and thickness values of individual corneal layers determined from VHF ultrasound data. RESULTS: VHF ultrasound resolved the epithelial, stromal cap, or flap and residual stromal layers 1 year after lamellar surgery. Asymmetric stromal tissue removal was differentiated from stromal cap irregularity. Epithelium acted to compensate for asymmetry of the stromal surface about the visual axis and for localized surface irregularities. Irregularities in the epithelial-stromal interface accounted for image ghosting present despite apparently normal videokeratography. Epithelial thickening was shown after uncomplicated myopic LASIK. Hyperopic LASIK demonstrated relative epithelial thickening localized to the region of ablation accounting for refractive regression. CONCLUSIONS: VHF ultrasound shows promise as a sensitive method of determining the anatomic correlates of optical complications in lamellar refractive surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0161-6420(99)90105-7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Reinstein, D. Z., Silverman, R. H., Sutton, H. F. S., & Coleman, D. J.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
1999-03
Volume
106
Issue
3
Pages
474-482
ISSN
0161-6420 (ISSN-L)
OpenAlex
W2086313367
Cited by
183
References
0
FWCI
11.55
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery. https://app.cochat.ai/papers/10.1016/s0161-6420(99)90105-7
The paper
Reinstein, D. Z., Silverman, R. H., Sutton, H. F. S., & Coleman, D. J. (1999). Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery. Ophthalmology. https://doi.org/10.1016/s0161-6420(99)90105-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.