Correlation of tear fluorescein clearance and schirmer test scores with ocular irritation symptoms
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To correlate and compare the Schirmer 1 test and a new method of measuring tear fluorescein clearance with the CytoFluor II fluorometer with the severity of ocular irritation symptoms, clinical signs of meibomian gland disease, corneal fluorescein staining scores, and corneal and conjunctival sensitivity. DESIGN: Case-control study. PARTICIPANTS: Forty patients presenting with a chief complaint of ocular irritation, and 40 asymptomatic control subjects of similar age distribution. INTERVENTION: All subjects completed a symptom questionnaire, a baseline ocular examination, fluorescein clearance test (FCT), and Schirmer 1 test. MAIN OUTCOME MEASURES: The FCT was performed with a CytoFluor II fluorophotometer by measuring the fluorescein concentration in minimally stimulated tear samples collected from the inferior tear meniscus 15 minutes after instillation of 5 microl of 2% sodium fluorescein. Severity of ocular irritation was assessed with a symptom questionnaire. Schirmer 1 test, biomicroscopic meibomian gland evaluation, corneal fluorescein staining score, and corneal and conjunctival sensation scores were assessed with the Cachet-Bonnet anesthesiometer in all subjects. RESULTS: Irritation symptoms correlated with higher log tear fluorescein concentration (symptomatic 3.08 +/- 0.62 units/,microl, normal control 1.89 +/- 0.7 units/microl, P < 0.005) and lower Schirmer 1 test scores (symptomatic 12.6 mm, normal control 22.3 mm, P < 0.005). The FCT showed greater predictive value for identifying ocular irritation than the Schirmer 1 test. A fluorescein concentration of 274 units//microl eliminated 80% of the normal subjects (specificity) and identified 85% of the abnormal subjects (sensitivity). Log of tear fluorescein concentration and the Schirmer 1 test correlated with meibomian gland orifice metaplasia (2.81 +/- 0.78 units/microl and 14.47 +/- 9.53 mm in those with metaplasia vs. 1.83 +/- 0.71 units/microl and 23.14 +/- 7.67 mm in those without metaplasia, P < 0.001) and with the percentage of acinar dropout. Both log of tear fluorescein concentration and the Schirmer 1 test correlated with corneal fluorescein staining (Pearson correlation of 0.394 P < 0.0001 for Schirmer 1 test and 0.312 P < 0.005 for log of tear fluorescein). In addition, log of tear fluorescein and Schirmer 1 test scores correlated with corneal and conjunctival sensation scores (Spearman's rho for corneal sensation: log of tear fluorescein -0.38, P < 0.003, Schirmer 1 test -0.39, P < 0.002, and for conjunctival sensation: log of tear fluorescein -0.391, P < 0.001, Schirmer 1 test -0.23, P < 0.061). CONCLUSIONS: The FCT shows a greater predictive value for ocular irritation than the Schirmer 1 test. It correlates better with age, meibomian gland dysfunction, and decreased corneal and conjunctival sensation. Decreased tear clearance was identified as a risk factor for ocular irritation, even in subjects with normal Schirmer scores. This simple technique may provide new clues into the mechanism and therapy of ocular irritation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
The Design and Analysis of Clinical Experiments.
Hills, M., & Fleiss, J. L. (1987) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982050 · Cited by 3,261
Report of the National Eye Institute/Industry workshop on Clinical Trials in Dry Eyes.
Lemp, M. A. (1995) · PubMed · Cited by 1,750
Primer on Certain Elements of Medical Decision Making
McNeil, B. J., Keeler, E., & Adelstein, S. J. (1975) · New England Journal of Medicine · doi:10.1056/nejm197507312930501 · Cited by 1,140
Prevalence of Dry Eye Among the Elderly
SCHEIN, O. D., MUÑOz, B., TIELSCH, J. M., BANDEEN-Roche, K., & WEST, S. (1997) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71688-5 · Cited by 790
The Control of Pain in Peripheral Tissue by Opioids
Stein, C. (1995) · New England Journal of Medicine · doi:10.1056/nejm199506223322506 · Cited by 718
Determination of tear volume and tear flow.
Mishima, S., Gasset, A. R., Klyce, S. D., & BAUM, J. L. (1966) · PubMed · Cited by 607
Pflugfelder, S. C., Tseng, S. C. G., Sanabria, O., Kell, H., Garcia, C. G., Felix, C., Feuer, W., & Reis, B. L. (1998) · Cornea · doi:10.1097/00003226-199801000-00007 · Cited by 558
Self-citationRelation between Signs and Symptoms of Dry Eye in the Elderly
Schein, O. D., Tielsch, J. M., Muñoz, B., Bandeen-Roche, K., & West, S. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30125-0 · Cited by 438
Jordan, A., & Baum, J. (1980) · Ophthalmology · doi:10.1016/s0161-6420(80)35143-9 · Cited by 306
Decrease in Corneal Sensitivity and Change in Tear Function in Dry Eye
Xu, K.-P., Yagi, Y., & Tsubota, K. (1996) · Cornea · doi:10.1097/00003226-199605000-00002 · Cited by 202
Inflammatory Cytokines in the Tears of Patients with Ocular Rosacea
Barton, K., Monroy, D. C., Nava, A., & Pflugfelder, S. C. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30014-1 · Cited by 156
Self-citationTear Flow and Evaporation in Patients with and without Dry Eye
Mathers, W. D., & Daley, T. E. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30637-4 · Cited by 150
Nordström, K., Norbäck, D., & Akselsson, R. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.3.170 · Cited by 77
(1992) · Springer eBooks · doi:10.1007/978-3-642-58130-4 · Cited by 49
Cited by
(2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70081-2 · Cited by 3,267
Grading Of Corneal and Conjunctival Staining in the Context of Other Dry Eye Tests
Bron, A. J., Evans, V. E., & Smith, J. A. (2003) · Cornea · doi:10.1097/00003226-200310000-00008 · Cited by 1,446
Knop, E., Knop, N., Millar, T., Obata, H., & Sullivan, D. A. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6997c · Cited by 1,061
The International Workshop on Meibomian Gland Dysfunction: Report of the Diagnosis Subcommittee
Tomlinson, A., Bron, A. J., Korb, D. R., Amano, S., Paugh, J. R., Pearce, E. I., Yee, R., Yokoi, N., Arita, R., & Dogru, M. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6997f · Cited by 855
The Lack of Association Between Signs and Symptoms in Patients With Dry Eye Disease
Nichols, K. K., Nichols, J. J., MPH, M., & Mitchell, G. L. (2004) · Cornea · doi:10.1097/01.ico.0000133997.07144.9e · Cited by 776
Metadata
- Authors
- Afonso, A. A., Monroy, D., Stern, M. E., Feuer, W. J., Tseng, S. C. G., & Pflugfelder, S. C.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 1999-04
- Volume
- 106
- Issue
- 4
- Pages
- 803-810
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2147254926
- Cited by
- 196
- References
- 15
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.