Developments in liquid-phase microextraction
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The volume of sample and extractant solutions are the most important factors that affect the enrichment factor.However, it should be noted that when the volume ratio of sample/ extractant increases the enrichment factor can increase.[84,164].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [164]
In the citing paper
“The volume of sample and extractant solutions are the most important factors that affect the enrichment factor.However, it should be noted that when the volume ratio of sample/ extractant increases the enrichment factor can increase.[84,164].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [164]
In the citing paper
“However, the nature of the target analytes and sample solution play an important role in salting-out effect [164,169].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [164]
In the citing paper
“In the LPME sampling of ionic analytes, pH of the sample solution should be precisely adjusted to allow ionization of the target analytes and obtain an efficient extraction [82,164].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [164]
Citations
Cites
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Applications of solid-phase microextraction in food analysis
Kataoka, H., Lord, H. L., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00309-5 · Cited by 1,119
Analytical Chemistry in a Drop. Solvent Extraction in a Microdrop
Liu, H., & Dasgupta, P. K. (1996) · Analytical Chemistry · doi:10.1021/ac960145h · Cited by 751
He, Y., & Lee, H. K. (1997) · Analytical Chemistry · doi:10.1021/ac970242q · Cited by 681
Jeannot, M. A., & Cantwell, F. F. (1997) · Analytical Chemistry · doi:10.1021/ac960814r · Cited by 558
Hollow Fiber-Protected Liquid-Phase Microextraction of Triazine Herbicides
Shen, G., & Lee, H. K. (2002) · Analytical Chemistry · doi:10.1021/ac010561o · Cited by 470
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Self-citationHeadspace Solvent Microextraction
Theis, A. L., Waldack, A. J., Hansen, S. M., & Jeannot, M. A. (2001) · Analytical Chemistry · doi:10.1021/ac015569c · Cited by 318
Cited by
Items 301–400 of 676
Aleksenko, S. S. (2012) · Journal of Analytical Chemistry · doi:10.1134/s1061934812020025 · Cited by 31
Sanagi, M. M., Miskam, M., Ibrahim, W. A. W., Hermawan, D., & Aboul-Enein, H. Y. (2010) · Journal of Separation Science · doi:10.1002/jssc.201000172 · Cited by 30
Pimparu, R., Nitiyanontakit, S., Miró, M., & Varanusupakul, P. (2016) · Talanta · doi:10.1016/j.talanta.2016.09.036 · Cited by 30
CHIANG, J., & HUANG, S. (2006) · Talanta · doi:10.1016/j.talanta.2006.05.065 · Cited by 30
Risks and challenges of pesticides in aquatic environments
Chavoshani, A., Hashemi, M., Amin, M. M., & Ameta, S. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818612-1.00005-2 · Cited by 30
Ebrahimzadeh, H., Yamini, Y., Kamarei, F., & Khalili‐Zanjani, M. R. (2006) · Talanta · doi:10.1016/j.talanta.2006.10.014 · Cited by 30
Yan, H., Cheng, X., & Yan, K. (2012) · The Analyst · doi:10.1039/c2an36046b · Cited by 29
Gas flow headspace liquid phase microextraction
Yang, C., Qiu, J., Ren, C., Piao, X., Li, X., Wu, X. F., & Li, D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.039 · Cited by 29
Chang, L., Bi, P., Li, X., & Wei, Y. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.01.013 · Cited by 29
Asgharinezhad, A. A., & Ebrahimzadeh, H. (2016) · RSC Advances · doi:10.1039/c5ra23488c · Cited by 28
Yazdi, A. S., & Mofazzeli, F. (2010) · Chromatographia · doi:10.1365/s10337-010-1731-6 · Cited by 28
Sun, M. Z., Tang, R., Wu, Q., Wang, C., & Wang, Z. (2013) · Analytical Methods · doi:10.1039/c3ay40966j · Cited by 28
Berhanu, T., Megersa, N., Solomon, T., & Jönsson, J. Å. (2008) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067310802357803 · Cited by 28
da Fonseca, P., & Bonato, P. S. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3271-1 · Cited by 28
Saraji, M., Farajmand, B., Ensafi, A. A., Allafchian, A., & Mirahmadi‐Zare, S. Z. (2010) · Talanta · doi:10.1016/j.talanta.2010.07.072 · Cited by 28
Kakhki, R. M., Nejati‐Yazdinejad, M., & Kakeh, F. (2013) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2013.09.020 · Cited by 27
Liu, Z., Liu, W., Wu, Q., Zang, X., Zhou, X. G., Zeng, X., & Wang, Z. (2011) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067311003628646 · Cited by 27
Hyötyläinen, T., & Riekkola, M. (2007) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.06.007 · Cited by 27
Kocúrová, L., Balogh, I. S., & Andruch, V. (2013) · Journal of Separation Science · doi:10.1002/jssc.201300575 · Cited by 26
Nanosensors for detection of pesticides in water
Steffens, C., Steffens, J., Graboski, A. M., Manzoli, A., & Leite, F. L. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804299-1.00017-5 · Cited by 26
SAMPLE PREPARATION FOR HIGH PERFORMANCE LIQUID CHROMATOGRAPHY: RECENT PROGRESS
Cobzac, S. C. A., & Gocan, S. (2011) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2011.588064 · Cited by 26
Wu, L., & Li, Z. (2021) · Journal of Separation Science · doi:10.1002/jssc.202001092 · Cited by 26
Sun, W., Qu, S., & Du, Z. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.01.029 · Cited by 25
Goh, S. X. L., & Lee, H. K. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.01.081 · Cited by 25
Kawaguchi, M., & Takatsu, A. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.12.022 · Cited by 25
Pena‐Pereira, F., Duarte, R. M. B. O., & Duarte, A. C. (2012) · Open Chemistry · doi:10.2478/s11532-011-0114-7 · Cited by 25
Gupta, M., Pillai, A. K. K. V., Jain, A., & Verma, K. K. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.042 · Cited by 25
Nanoconfined Liquid Phase Nanoextraction Based on Carbon Nanofibers
Zou, Y., Wang, L., Sun, H., Wang, G., Meng, L., Quinto, M., & Li, D. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01462 · Cited by 25
Lopes, D., Bernardi, G., Pinheiro, G. D. L. C., Campedelli, R. R., de Souza, B. S., & Carasek, E. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.05.032 · Cited by 25
Zhou, J., Zeng, P., Cheng, Z. H., Liu, J., Wang, F. Q., & Qian, R. J. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.06.022 · Cited by 25
Yang, C., Zhao, J., Wang, J., Yu, H., Piao, X., & Li, D. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.02.087 · Cited by 25
Fakhari, A. R., Tabani, H., & Nojavan, S. (2011) · Analytical Methods · doi:10.1039/c1ay05037k · Cited by 25
Jouyban, A., Farajzadeh, M. A., Khoubnasabjafari, M., Jouyban-Gharamaleki, V., & Afshar Mogaddam, M. R. (2019) · Analytical Methods · doi:10.1039/c8ay02279h · Cited by 24
Zhou, J., Zhang, Q., Sun, J. B., Sun, X., & Zeng, P. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.01.013 · Cited by 24
Tsai, C.-J., Liao, F.-Y., Weng, J., & Feng, C. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.09.069 · Cited by 24
Hashemi, M., Zohrabi, P., & Torkejokar, M. (2016) · Separation and Purification Technology · doi:10.1016/j.seppur.2016.11.073 · Cited by 24
Manzo, V., Becerra‐Herrera, M., Arismendi, D., Molina-Balmaceda, A., Caraballo, M. A., & Richter, P. (2019) · Analytical Methods · doi:10.1039/c9ay02076d · Cited by 24
Pillai, A. K. K. V., Jain, A., & Verma, K. K. (2009) · Talanta · doi:10.1016/j.talanta.2009.10.027 · Cited by 24
Wang, J., Jiang, D., & Yan, X. (2005) · Talanta · doi:10.1016/j.talanta.2005.06.036 · Cited by 24
Merlo, F., Profumo, A., Fontàs, C., & Anticó, E. (2021) · Microchemical Journal · doi:10.1016/j.microc.2021.107120 · Cited by 24
Saraji, M., & Boroujeni, M. K. (2011) · Microchimica Acta · doi:10.1007/s00604-011-0612-5 · Cited by 24
Shrivas, K. K., & Patel, D. K. (2010) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2010.10.003 · Cited by 24
Valverde, I., Espín, S., Gómez‐Ramírez, P., Navas, I., María-Mójica, P., Sánchez‐Virosta, P., Jiménez, P., Torres-Chaparro, M. Y., & García-Fernández, A. J. (2021) · Ecotoxicology · doi:10.1007/s10646-021-02411-8 · Cited by 24
Quintanilla, I., Perelló, C., Merlo, F., Profumo, A., Fontàs, C., & Anticó, E. (2023) · Polymers · doi:10.3390/polym15020314 · Cited by 24
Singh, V., Purohit, A. K., Chinthakindi, S., Goud, D. R., Tak, V., Pardasani, D., Shrivastava, A. R., & Dubey, D. K. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.01.028 · Cited by 24
Panhwar, A. H., Tüzen, M., & Kazi, T. G. (2019) · Atomic Spectroscopy · doi:10.46770/as.2019.06.005 · Cited by 24
Rodríguez‐Gonzalo, E., Domínguez‐Álvarez, J., Ruano‐Miguel, L., & Carabias-Martínez, R. (2008) · Electrophoresis · doi:10.1002/elps.200800277 · Cited by 24
Es’haghi, Z., Hoseini, H. A., Mohammadi-Nokhandani, S., & Ebrahimi, J. (2013) · Journal of Advanced Research · doi:10.1016/j.jare.2013.11.003 · Cited by 23
Magalhães, I. R. D. S., & Bonato, P. S. (2008) · Journal of Separation Science · doi:10.1002/jssc.200800320 · Cited by 23
Ruan, C., Zhao, X., & Liu, C. (2015) · Journal of Separation Science · doi:10.1002/jssc.201401162 · Cited by 23
Xu, H., Pan, W., Song, D., & Yang, G. (2007) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0718345 · Cited by 23
Mekiki, D., Kalogerakis, N. E., & Psillakis, E. (2006) · Chromatographia · doi:10.1365/s10337-005-0693-6 · Cited by 23
Self-citationTapadia, K., Shrivas, K. K., & Upadhyay, L. S. B. (2011) · Chromatographia · doi:10.1007/s10337-011-2096-1 · Cited by 23
de Paiva, M. J. N., Menezes, H. C., da Silva, J. C. C., Resende, R. R., & Cardeal, Z. D. L. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.02.016 · Cited by 23
Pan, W., Xu, H., Cui, Y., Song, D., & Feng, Y. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.07.004 · Cited by 23
Development of high performance electrochemical solvent extraction method
Okugaki, T., Kitatsuji, Y., Kasuno, M., Yoshizumi, A., Kubota, H., Shibafuji, Y., Maeda, K., Yoshida, Z., & Kihara, S. (2009) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2009.01.022 · Cited by 23
HF-LPME as a green alternative for the preconcentration of nickel in natural waters
Vergel, C., Montoya-Mayor, R., Mendiguchía, C., García-Vargas, M., & Moreno, C. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5896-8 · Cited by 22
Fang, C., Xiong, Y., Liang, Q., Li, Y., & Peng, P. (2011) · Organic Geochemistry · doi:10.1016/j.orggeochem.2011.01.009 · Cited by 22
Attari, S. G., Bahrami, A., Shahna, F. G., & Heidari, M. (2014) · Journal of Environmental Health Science and Engineering · doi:10.1186/s40201-014-0123-5 · Cited by 22
Analytical methods for determination of selective serotonin reuptake inhibitor antidepressants
Şentürk, Z., Saka, C., & Teğin, İ. (2011) · Reviews in Analytical Chemistry · doi:10.1515/revac.2011.018 · Cited by 22
Moein, M. M., Javanbakht, M., Karimi, M. B., & Akbari‐adergani, B. (2015) · Journal of Separation Science · doi:10.1002/jssc.201401186 · Cited by 22
Kanimozhi, S., Basheer, C., Neveliappan, S., Ang, K., Xue, F., & Lee, H. K. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2012.10.008 · Cited by 22
Determination of Sudan III in Food by Supramolecular Microextraction and Spectrophotometry
Soylak, M., Ahmed, H. E. H., & Uzcan, F. (2022) · Analytical Letters · doi:10.1080/00032719.2022.2112047 · Cited by 22
Magalhães, I. R. D. S., & Bonato, P. S. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2620-4 · Cited by 22
Cataluminescence‐based sensors: principle, instrument and application
Tang, F., Guo, C., Chen, J., Zhang, X., Zhang, S., & Wang, X. (2014) · Luminescence · doi:10.1002/bio.2702 · Cited by 22
Zanjani, M. R. K., Yamini, Y., & Shariati, S. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.01.004 · Cited by 22
Liu, Z., Liu, W., Rao, H., Feng, T., Li, C., Wang, C., & Wang, Z. (2012) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067311003628638 · Cited by 21
Vázquez, M. D. M. P., Vázquez, P. P., Galera, M. M., & Sánchez, L. M. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200222 · Cited by 21
Yazdi, A. S., Khaleghi-Miran, S.-H., & Es’haghi, Z. (2010) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067310902962593 · Cited by 21
Wang, H., Wu, W., Wei, D., Guo, Z., & Wang, S. (2014) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2014.10.017 · Cited by 21
Shrivas, K. K., & Patel, D. K. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.11.005 · Cited by 21
Trends in microextraction approaches for handling human hair extracts - A review
Rosado, T., Barroso, M., Vieira, D. N., & Gallardo, E. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338792 · Cited by 21
Jeong, S., Hajba, L., Guttman, A., Seol, J., & Chung, D. S. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117058 · Cited by 21
Saraji, M., & Farajmand, B. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.01.046 · Cited by 21
Tamandani, M., Hashemi, S. H., Kaykhaii, M., Keikha, A. J., & Nasiriyan, A. (2022) · BMC Chemistry · doi:10.1186/s13065-022-00807-z · Cited by 21
Zhou, J., Sun, J. B., Zheng, P., Liu, J., Cheng, Z. H., Zeng, P., & Wang, F. Q. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6013-8 · Cited by 21
Corazza, G., Merib, J., do Carmo, S. N., Mendes, L. D., & Carasek, E. (2019) · Journal of the Brazilian Chemical Society · doi:10.21577/0103-5053.20190016 · Cited by 21
Chao, Y.-Y., Jian, Z.-X., Tu, Y.-M., Wang, H.-W., & Huang, Y. (2013) · The Analyst · doi:10.1039/c3an36696k · Cited by 20
Borijihan, G., Li, Y., Gao, J., & Bao, J. J. (2014) · Journal of Separation Science · doi:10.1002/jssc.201300954 · Cited by 20
Hamedi, R., Aghaie, A. B. G., & Hadjmohammadi, M. R. (2018) · Journal of Separation Science · doi:10.1002/jssc.201701090 · Cited by 20
Dispersive suspended microextraction
Yang, Z., Liu, Y. S., Lu, Y., Wu, T., Zhou, Z., & Liu, D. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.09.001 · Cited by 20
Unidirectional solute transfer using a Janus membrane
Dong, Y., Li, J., Pedersen‐Bjergaard, S., & Huang, C. (2019) · Journal of Membrane Science · doi:10.1016/j.memsci.2019.117723 · Cited by 20
Cha, Y.-B., & Myung, S. (2013) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2013.34.11.3444 · Cited by 20
Supharoek, S.-A., Ponhong, K., Siriangkhawut, W., & Grudpan, K. (2018) · Microchemical Journal · doi:10.1016/j.microc.2018.08.048 · Cited by 20
Lim, E., Kim, B., Oh, M. S., & You, J. B. (2023) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2023.03.201 · Cited by 19
Saraji, M., & Ghambari, H. (2015) · Journal of Separation Science · doi:10.1002/jssc.201500556 · Cited by 19
Hu, X., Huang, Y., Tao, Y., Yin, D., & Liu, J. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0256-x · Cited by 19
Yazdi, A. S., Beiknejad, D., & Es’haghi, Z. (2005) · Chromatographia · doi:10.1365/s10337-005-0581-0 · Cited by 19
Saraji, M., Bidgoli, A. A. H., Khayamian, T., & Moradmand, A. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.10.026 · Cited by 19
Karami, M., Yamini, Y., & Asl, Y. A. (2019) · Talanta · doi:10.1016/j.talanta.2019.120235 · Cited by 19
Benzimidazole Fungicides in Environmental Samples: Extraction and Determination Procedures
Rodrguez, J. J. S., Torres-Padrón, M. E., Aufartov, J., & Sosa‐Ferrera, Z. (2010) · InTech eBooks · doi:10.5772/10481 · Cited by 19
Sibiya, P., Cukrowska, E., Jönsson, J. Å., & Chimuka, L. (2013) · Chromatographia · doi:10.1007/s10337-013-2420-z · Cited by 19
Akhtar, A., Kazi, T. G., Afridi, H. I., Baig, J. A., & Khan, M. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104963 · Cited by 19
Green Sample Preparation Methods
Bendicho, C., Lavilla, I., Pena‐Pereira, F., & Costas‐Rodríguez, M. (2011) · Royal Society of Chemistry eBooks · doi:10.1039/9781849732963-00063 · Cited by 18
Rahnama, R., Nakhaei, J. M., & Jamali, M. R. (2012) · Environmental Monitoring and Assessment · doi:10.1007/s10661-012-3044-8 · Cited by 18
Viable and Rapid Determination of Organochlorine Pesticides in Water
Aydın, S. (2010) · CLEAN - Soil Air Water · doi:10.1002/clen.201000059 · Cited by 18
Lei, L., Kang, M., Li, N., Yang, X. D., Liu, Z. L., Wang, Z., Zhang, L. Y., Zhang, H. Q., & Yu, Y. (2014) · Analytical Methods · doi:10.1039/c4ay00007b · Cited by 18
Fakhari, A. R., Tabani, H., & Nojavan, S. (2012) · Drug Testing and Analysis · doi:10.1002/dta.1387 · Cited by 18
Jung, M.-J., Shin, Y.-J., Oh, S.-Y., Kim, N., Kim, K., & Lee, D.-S. (2006) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2006.27.2.231 · Cited by 18
Metadata
- Authors
- Psillakis, E., & Kalogerakis, N.
- Affiliations
- Technical University of Crete (GR)
- Corresponding author
- Psillakis, E.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2003-10
- Volume
- 22
- Issue
- 9
- Pages
- 565-574
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2139296321
- Cited by
- 608
- References
- 44
- Citations by year
- 2026: 8 · 2025: 5 · 2024: 9 · 2023: 6 · 2022: 12 · 2021: 10 · 2020: 16 · 2019: 25 · 2018: 18 · 2017: 15 · 2016: 26 · 2015: 37 · 2014: 48 · 2013: 34 · 2012: 45
- FWCI
- 21.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- TrAC Trends in Analytical Chemistry (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- liquid-phase microextraction, hollow fiber membranes, sample preparation, solvent-free extraction, method optimization, solid-phase microextraction, single-drop microextraction, environmental compatibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.