Multiple anatomical landmark calibration for optimal bone pose estimation
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Least-Squares Fitting of Two 3-D Point Sets
Arun, K. S., Huang, T. S., & Blostein, S. D. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767965 · Cited by 3,952
Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677
Self-citationPosition and orientation in space of bones during movement: experimental artefacts
Cappozzo, A., Catani, F., Leardini, A., Benedetti, M., & Della Croce, U. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00046-1 · Cited by 756
Self-citationDetermining the movements of the skeleton using well-configured markers
Söderkvist, I., & Wedin, P.-Å. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90098-y · Cited by 735
A procedure for determining rigid body transformation parameters
Challis, J. H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00116-l · Cited by 398
3-D attitude representation of human joints: A standardization proposal
Woltring, H. J. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90191-0 · Cited by 251
A solidification procedure to facilitate kinematic analyses based on video system data
Chèze, L., Fregly, B. J., & Dimnet, J. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95278-d · Cited by 222
Optimization and smoothing techniques in movement analysis
Cappello, A., Palombara, P. F. L., & Leardini, A. (1996) · International Journal of Bio-Medical Computing · doi:10.1016/0020-7101(96)01167-1 · Cited by 77
Self-citation
Cited by
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Self-citationLu, T.-W., & O’Connor, J. J. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00158-4 · Cited by 924
Quantification of soft tissue artifact in lower limb human motion analysis: A systematic review
Peters, A., Galna, B., Sangeux, M., Morris, M., & Baker, R. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.09.004 · Cited by 367
Manal, K., McClay, I., Stanhope, S., Richards, J., & Galinat, B. (2000) · Gait & Posture · doi:10.1016/s0966-6362(99)00042-9 · Cited by 284
Della Croce, U., Cappozzo, A., & Kerrigan, D. C. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513282 · Cited by 256
Self-citationCorrecting for deformation in skin-based marker systems
Alexander, E. J., & Andriacchi, T. P. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00192-5 · Cited by 253
Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics
Lucchetti, L., Cappozzo, A., Cappello, A., & Croce, U. D. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00083-9 · Cited by 211
“Vectors w are usually assumed to be time invariant and determined through an ad hoc experiment referred to as ‘anatomical landmark calibration’ (Cappozzo, 1984; Cappozzo et al., 1995a; Cappello et al., 1997).”
MethodSelf-citationA model-based method for the reconstruction of total knee replacement kinematics
Zuffi, S., Leardini, A., Catani, F., Fantozzi, S., & Cappello, A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811310 · Cited by 185
“Recent papers from some of the authors have shown that the errors involved can be as large as few centimeters for joint translations and several degrees for rotations [4], [5].”
BackgroundSelf-citationOn the influence of soft tissue coverage in the determination of bone kinematics using skin markers
Taylor, W. R., Ehrig, R. M., Duda, G. N., Schell, H., Seebeck, P., & Heller, M. O. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2005.02.006 · Cited by 177
Quantification of Pelvic Soft Tissue Artifact in Multiple Static Positions
Hara, R., Sangeux, M., Baker, R., & McGinley, J. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2013.10.001 · Cited by 43
“Double calibration procedures typically involve two static calibrations at end-range positions of the joint of interest as a reference [15].”
Background
Metadata
- Authors
- Cappello, A., Cappozzo, A., La Palombara, P. F., Lucchetti, L., & Leardini, A.
- Venue
- Human Movement Science
- Publisher
- Elsevier BV
- Published
- 1997-04
- Volume
- 16
- Issue
- 2-3
- Pages
- 259-274
- ISSN
- 0167-9457 (ISSN-L)
- OpenAlex
- W2060385379
- Cited by
- 161
- References
- 8
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.