The influence of formulation variables on the performance of alternative propellant-driven metered dose inhalers
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Derjaguin, B. V. (1941) · Cited by 5,490
Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone
Molina, M. J., & Rowland, F. S. (1974) · Nature · doi:10.1038/249810a0 · Cited by 4,332
Large losses of total ozone in Antarctica reveal seasonal ClOx/NOx interaction
Farman, J. C., Gardiner, B. G., & Shanklin, J. D. (1985) · Nature · doi:10.1038/315207a0 · Cited by 3,520
Bates, D. V., Fish, B., Hatch, T. F., Mercer, T. T., & Morrow, P. E. (1966) · PubMed · Cited by 771
Effect of an Inhaled Corticosteroid on Airway Inflammation and Symptoms in Asthma
Djukanović, R., Wilson, J. W., Britten, K. M., Wilson, S. J., Walls, A. F., Roche, W. R., Howarth, P. H., & Holgate, S. T. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.3.669 · Cited by 639
TILLIE-LEBLOND, I., PUGIN, J., MARQUETTE, C.-H., LAMBLIN, C., SAULNIER, F., BRICHET, A., WALLAERT, B., TONNEL, A.-B., & GOSSET, P. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9805115 · Cited by 259
Daley‐Yates, P. T., Price, A. C., Sisson, J. R., Pereira, A., & Dallow, N. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01374.x · Cited by 225
Dispersion and Characterization of Pharmaceutical Dry Powder Aerosols
Dunber, C. A., Hickey, A. J., & Holzner, P. (1998) · KONA Powder and Particle Journal · doi:10.14356/kona.1998007 · Cited by 197
Inflammation and Airway Function in Asthma: What You See Is Not Necessarily What You Get
Haley, K. J., & Drazen, J. M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.ed-19 · Cited by 185
De Blaquiere, P., Christensen, D. B., Carter, W. B., & Martin, T. R. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/140.4.910 · Cited by 185
Hollow Porous Particles in Metered Dose Inhalers
Dellamary, L. A., Tarara, T. E., Smith, D. J., Woelk, C. H., Adractas, A., Costello, M. L., Gill, H., & Weers, J. G. (2000) · Pharmaceutical Research · doi:10.1023/a:1007513213292 · Cited by 179
Dolovich, M. A. (2000) · Respiratory Care · doi:10.1177/002013240004500604 · Cited by 164
The integrity of the scientific literature
Stewart, W. W., & Feder, N. (1987) · Nature · doi:10.1038/325207a0 · Cited by 163
Drug Properties Affecting Aerosol Behavior
Suarez, S., & Hickey, A. J. (2000) · Respiratory Care · doi:10.1177/002013240004500609 · Cited by 150
McFadden, E. R. (1995) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(95)70206-7 · Cited by 146
The Mechanics of Inhaled Pharmaceutical Aerosols
(2001) · Elsevier eBooks · doi:10.1016/b978-0-12-256971-5.x5000-7 · Cited by 145
Inhalation Delivery of Therapeutic Peptides and Proteins
Adjei, A. L., & Gupta, P. (1997) · doi:10.1201/9781420001242 · Cited by 136
Transition to CFC-free metered dose inhalers — into the new millennium
McDonald, K. J., & Martin, G. P. (2000) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(00)00401-4 · Cited by 109
Metered-Dose Inhalers, Dry Powder Inhalers, and Transitions
Fink, J. B. (2000) · Respiratory Care · doi:10.1177/002013240004500606 · Cited by 105
Stability of emulsions of water in oil
Albers, W., & Overbeek, J. T. G. (1959) · Journal of Colloid Science · doi:10.1016/0095-8522(59)90015-7 · Cited by 98
Gonda, I. (2003) · Drugs and the pharmaceutical sciences · doi:10.1201/9780203912898.ch3 · Cited by 85
Influence of Formulation on Aerosol Particle Size
Polli, G. P., Grim, W. M., Bacher, F. A., et al. (1969) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600580422 · Cited by 79
Butz, N., Porté, C., Courrier, H. M., Krafft, M. P., & Vandamme, T. F. (2002) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(02)00086-8 · Cited by 58
Why Particle Size Should Affect Clinical Response to Inhaled Therapy
Howarth, P. H. (2001) · Journal of Aerosol Medicine · doi:10.1089/08942680150506312 · Cited by 55
Convery, R. P., Leitch, D. N., Bromly, C. L., Ward, R., Bartlett, G., & Hendrick, D. J. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.15a05.x · Cited by 47
Taylor, K. (1997) · International Journal of Pharmaceutics · Cited by 43
Sommerville, M. L., Cain, J. B., Johnson, C. S., & Hickey, A. J. (2000) · Pharmaceutical Development and Technology · doi:10.1081/pdt-100100537 · Cited by 38
Influence of Propellant Composition on Drug Delivery from a Pressurized Metered-Dose Inhaler
Williams, R. O., Repka, M. A., & Liu, J. (1998) · Drug Development and Industrial Pharmacy · doi:10.3109/03639049809082724 · Cited by 38
Health-Related Quality of Life in Moderate Asthma
Juniper, E. F., & Buist, A. S. (1999) · CHEST Journal · doi:10.1378/chest.116.5.1297 · Cited by 36
Everard, M. L. (2000) · Thorax · doi:10.1136/thorax.55.10.811 · Cited by 31
Thiel, C. G. (1998) · Journal of Aerosol Medicine · doi:10.1089/jam.1998.11.suppl_1.s-43 · Cited by 30
Bäckström, K., & Nilsson, P. G. (1988) · Journal of Aerosol Science · doi:10.1016/0021-8502(88)90110-3 · Cited by 8
Assessment End Points for Inhaled Drug Delivery
Anderson, P. C. (2000) · Respiratory Care · doi:10.1177/002013240004500615 · Cited by 6
Cited by
Aerosol drug delivery: developments in device design and clinical use
Dolovich, M. B., & Dhand, R. (2011) · The Lancet · doi:10.1016/s0140-6736(10)60926-9 · Cited by 505
Inhalation drug delivery devices: technology update
Garcia-Contreras, L., Ibrahim, M., & Verma, R. (2015) · Medical Devices: Evidence and Research · doi:10.2147/mder.s48888 · Cited by 306
Biodegradable mucoadhesive particulates for nasal and pulmonary antigen and DNA delivery
ALPAR, H., SOMAVARAPU, S., ATUAH, K., & BRAMWELL, V (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.09.004 · Cited by 287
Principles of Metered-Dose Inhaler Design
Newman, S. P. (2005) · Respiratory Care · doi:10.4187/respcare.05501177 · Cited by 244
“The design of the actuator is important, particularly because the aerosol particle size is determined partly by the nozzle diameter, which ranges between 0.14 mm and 0.6 mm. 14 Aerosol particle size varies directly with nozzle diameter, 4,5 and particle size influences lung deposition.”
InfluentialOptimizing drug delivery in COPD: The role of inhaler devices
Rogliani, P., Calzetta, L., Coppola, A., Cavalli, F., Ora, J., Puxeddu, E., Matera, M. G., & Cazzola, M. (2017) · Respiratory Medicine · doi:10.1016/j.rmed.2017.01.006 · Cited by 212
Metadata
- Authors
- Smyth, H. D. C.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 55
- Issue
- 7
- Pages
- 807-828
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W2045467856
- Cited by
- 159
- References
- 33
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.