Artificial Sensibility Based on the Use of Piezoresistive Sensors: Preliminary observations
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Piezoresistive sensors, applied to the fingertips of non-sensate fingers, were used for the detection of touch and pressure in four patients with recent median nerve repairs, and in one patient using a myoelectric prosthesis. The signals from the sensors, produced by the tactile stimuli, were processed and transposed as electrical stimuli to sensate skin of the ipsi- or contralateral arm by the use of skin electrodes. With this setup the test subjects could rapidly learn to differentiate between tactile stimuli applied to different fingers, thereby regaining spatial, resolution in the hand. All five patients rapidly improved their ability to regulate the power of pinch grip without the help of vision. The patient with a hand prosthesis rapidly learned to discriminate between four different levels of pressure, applied to the thumb by four different Semmes-Weinstein monofilaments (75, 125, 280 and 450 g). These results indicate that the system is of potential value for patients lacking sensibility or using prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Factors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Self-citationControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Haptics in minimally invasive surgery – a review
Westebring – van der Putten, E. P., Goossens, R. H. M., Jakimowicz, J. J., & Dankelman, J. (2008) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701820242 · Cited by 328
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
“The significant reduction of the requisite grasping force in our study closely correlates with that obtained in the work of Lundborg et al.12 Consequently, the use of a closedloop feedback system based on vibration or electrical stimuli can be recommended.”
ResultForearm amputees' views of prosthesis use and sensory feedback
Wijk, U., & Carlsson, I. (2015) · Journal of Hand Therapy · doi:10.1016/j.jht.2015.01.013 · Cited by 114
Metadata
- Authors
- LUNDBORG, G., ROSÉN, B., LINDSTRÖM, K., & LINDBERG, S.
- Venue
- Journal of Hand Surgery
- Publisher
- SAGE Publications
- Published
- 1998-10
- Volume
- 23
- Issue
- 5
- Pages
- 620-626
- ISSN
- 0266-7681 (ISSN-L)
- OpenAlex
- W2027592802
- Cited by
- 37
- References
- 1
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial Sensibility Based on the Use of Piezoresistive Sensors: Preliminary observations. https://app.cochat.ai/papers/10.1016/s0266-7681(98)80016-8
- The paper
- LUNDBORG, G., ROSÉN, B., LINDSTRÖM, K., & LINDBERG, S. (1998). Artificial Sensibility Based on the Use of Piezoresistive Sensors: Preliminary observations. Journal of Hand Surgery. https://doi.org/10.1016/s0266-7681(98)80016-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.