Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 17 of the 19 references it cites were found in a registry or an index.

Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands

Pylatiuk, Christian, Kargov, Artem, Schulz, Stefan · 2006 · JPO Journal of Prosthetics and Orthotics

Abstract

In Brief Myoelectrically powered prosthetic hands lack sensory feedback relating to the force exerted by the artificial hand on a grasped object. The degree of control is imprecise, and often much more force than necessary is applied. The aim of this study was to develop and evaluate a force feedback system considering design constraints, providing the user with closed-loop control. Different methods and design criteria for providing myoelectric prosthetic hands with force feedback were analyzed, with stimulation by vibration being preferred. A new feedback system was designed, consisting of a miniature vibration motor, a piezoresistive force sensor, and control electronics. Grasping forces with and without feedback were recorded and compared from five habitual myoelectric hand users when grasping a hand dynamometer with different weights attached to it. All five patients rapidly improved their ability to regulate the grasping force without the help of vision when feedback was applied. An average force reduction of 37% was found when vibration was applied indirectly to the hand, and a decrease of 54% was found when feedback was applied directly to the skin of the residual limb. Constraints for a prosthetic force feedback system such as low power consumption, compactness, and being imperceptible to others are included in the design. General acceptance of vibration as a feedback signal was good, especially when applied indirectly. The results indicate that the new system is of potential value for myoelectric prosthetic hand users. More precise control is possible, and redundant grasping force can be diminished with a feedback system. A new system may offer valuable assistance to myoelectric prosthetic hand users to more accurately gauge the force needed for a particular task. People with such artificial hands suffer from a lack of adequate feedback compared with body-powered prostheses. Different methods for providing myoelectric prosthetic hands with force feedback were analyzed, and a new feedback system was designed, consisting of a sensor capable of changing its resistance under physical pressure, a miniature vibration motor, and control electronics.

Overview

Integrity signals

Registry

Crossref · 10.1097/00008526-200604000-00007

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Research works printed but not linked: 3

  1. Shannon, 1974, Biomed Eng, 9, 247
  2. Pylatiuk, 2005, Biomed Eng, 50, 1521
  3. Kargov, 2004, Technol Health Care, 12, 193

Cited by

See all 156

Metadata

Authors
Pylatiuk, C., Kargov, A., & Schulz, S.
Corresponding author
Pylatiuk, Christian
Venue
JPO Journal of Prosthetics and Orthotics
Published
2006-04
Volume
18
Issue
2
Pages
57-61
ISSN
1040-8800 (ISSN-L)
OpenAlex
W2053247083
Cited by
156
References
19
Citations by year
2026: 1 · 2025: 3 · 2024: 1 · 2023: 5 · 2022: 5 · 2021: 7 · 2020: 7 · 2019: 11 · 2018: 8 · 2017: 11 · 2016: 11 · 2015: 14 · 2014: 17 · 2013: 13 · 2012: 16
FWCI
3.84
Type
journal article
Language
en
Open access
closed
Locations
JPO Journal of Prosthetics and Orthotics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
Keywords
myoelectric prosthetic hand, force feedback, vibration feedback, piezoresistive force sensor, grip force control, feedback control, low-cost prosthetic design, hand dynamometer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands. https://app.cochat.ai/papers/10.1097/00008526-200604000-00007
The paper
Pylatiuk, C., Kargov, A., & Schulz, S. (2006). Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands. JPO Journal of Prosthetics and Orthotics. https://doi.org/10.1097/00008526-200604000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.