Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Abstract
In Brief Myoelectrically powered prosthetic hands lack sensory feedback relating to the force exerted by the artificial hand on a grasped object. The degree of control is imprecise, and often much more force than necessary is applied. The aim of this study was to develop and evaluate a force feedback system considering design constraints, providing the user with closed-loop control. Different methods and design criteria for providing myoelectric prosthetic hands with force feedback were analyzed, with stimulation by vibration being preferred. A new feedback system was designed, consisting of a miniature vibration motor, a piezoresistive force sensor, and control electronics. Grasping forces with and without feedback were recorded and compared from five habitual myoelectric hand users when grasping a hand dynamometer with different weights attached to it. All five patients rapidly improved their ability to regulate the grasping force without the help of vision when feedback was applied. An average force reduction of 37% was found when vibration was applied indirectly to the hand, and a decrease of 54% was found when feedback was applied directly to the skin of the residual limb. Constraints for a prosthetic force feedback system such as low power consumption, compactness, and being imperceptible to others are included in the design. General acceptance of vibration as a feedback signal was good, especially when applied indirectly. The results indicate that the new system is of potential value for myoelectric prosthetic hand users. More precise control is possible, and redundant grasping force can be diminished with a feedback system. A new system may offer valuable assistance to myoelectric prosthetic hand users to more accurately gauge the force needed for a particular task. People with such artificial hands suffer from a lack of adequate feedback compared with body-powered prostheses. Different methods for providing myoelectric prosthetic hands with force feedback were analyzed, and a new feedback system was designed, consisting of a sensor capable of changing its resistance under physical pressure, a miniature vibration motor, and control electronics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sensory substitution, such as vibration on a residual limb with intensity proportional to pressure at the prosthetic fingertip, improves prosthetic control in limited situations (8, 9), but has not been widely adopted as the vibration is often described as distracting (8).”
From A neural interface provides long-term stable natural touch perception (2014) · cites this paper as [8]
Citations
Cites
Factors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 1×
“Moreover, the range of signal current between the detection threshold (1 mA) and pain threshold (2 mA) is narrow, and pain sensations are reported to be the major disadvantage of electrotactile stimulation.(7,13) For this reason, other researchers proposed vibration(10,14,15) or pressure(16,17) to transmit information.”
BackgroundBunnell, S. (1949) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-194905000-00012 · Cited by 764
Effect of Contactor Area on the Vibrotactile Threshold
Verrillo, R. T. (1963) · The Journal of the Acoustical Society of America · doi:10.1121/1.1918868 · Cited by 381
Closed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158 · cited 1×
“Since then, research groups all over the world have designed force and velocity feedback systems.(5,6) Of the several feedback principles published and discussed extensively in the last decades, two are considered to have the best clinical viability: electrical surface stimulation (ESS) and mechanical surface stimulat…”
BackgroundPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 1×
“An advantage associated with mechanical stimulation for force feedback is the universal psychological acceptance.(7,16) However, the actuators used for mechanical feedback have been too bulky and could not be integrated in a prosthetic hand.”
BackgroundA comparison of alternative means of providing sensory feedback on upper limb prostheses
Shannon, G. F. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478123 · Cited by 93 · cited 3×
“Moreover, the range of signal current between the detection threshold (1 mA) and pain threshold (2 mA) is narrow, and pain sensations are reported to be the major disadvantage of electrotactile stimulation.(7,13) For this reason, other researchers proposed vibration(10,14,15) or pressure(16,17) to transmit information.”
BackgroundA myoelectrically-controlled prosthesis with sensory feedback
Shannon, G. F. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440956 · Cited by 92 · cited 2×
“This confirms the statements made by Shannon.22 Two of the test persons remarked that the vibration signal becomes more disturbing than helpful after some seconds.”
ResultSENSORY SUBSTITUTION IN PROSTHETICS
Lundborg, G., & Rosén, B. (2001) · Hand Clinics · doi:10.1016/s0749-0712(21)00526-6 · Cited by 88
A shoulder pad insert vibrotactile display
Toney, A., Dunne, L. E., Thomas, B. H., & Ashdown, S. P. (2004) · Proceedings · doi:10.1109/iswc.2003.1241391 · Cited by 72
Research works printed but not linked: 3
- Shannon, 1974, Biomed Eng, 9, 247
- Pylatiuk, 2005, Biomed Eng, 50, 1521
- Kargov, 2004, Technol Health Care, 12, 193
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Experimentally assessing [104,105] or simulating [106] the user’s interaction with the orthotic or prosthetic”
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
“Sensory substitution, such as vibration on a residual limb with intensity proportional to pressure at the prosthetic fingertip, improves prosthetic control in limited situations (8, 9), but has not been widely adopted as the vibration is often described as distracting (8).”
BackgroundSensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
“have been used in research with the Otto Bock, Motion Control and iLimb myoelectric prostheses [25], [26], [27], and with the Cyber- [28], MANUS- [29], Fluid- [30] and Smart- [24] hands.”
BackgroundMethodInfluentialMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
“Evaluation of grasping performances showed a 15 to 77 percent decrease in applied grasping forces [74], but no significant differences in performance were noted when compared with the nonfeedback situation [57].”
BackgroundControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Metadata
- Authors
- Pylatiuk, C., Kargov, A., & Schulz, S.
- Corresponding author
- Pylatiuk, Christian
- Venue
- JPO Journal of Prosthetics and Orthotics
- Published
- 2006-04
- Volume
- 18
- Issue
- 2
- Pages
- 57-61
- ISSN
- 1040-8800 (ISSN-L)
- OpenAlex
- W2053247083
- Cited by
- 156
- References
- 19
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 5 · 2022: 5 · 2021: 7 · 2020: 7 · 2019: 11 · 2018: 8 · 2017: 11 · 2016: 11 · 2015: 14 · 2014: 17 · 2013: 13 · 2012: 16
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- JPO Journal of Prosthetics and Orthotics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Keywords
- myoelectric prosthetic hand, force feedback, vibration feedback, piezoresistive force sensor, grip force control, feedback control, low-cost prosthetic design, hand dynamometer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands. https://app.cochat.ai/papers/10.1097/00008526-200604000-00007
- The paper
- Pylatiuk, C., Kargov, A., & Schulz, S. (2006). Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands. JPO Journal of Prosthetics and Orthotics. https://doi.org/10.1097/00008526-200604000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.