The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ultrasound backscatter and attenuation in human liver with diffuse disease
Open accessAbstract
Ultrasound backscatter and attenuation in the liver were measured in patients with diffuse liver disease and in 35 volunteers who had no history of liver ailments. Measurements were done using radiofrequency (RF) echo signals derived from a clinical scanner; a reference phantom was scanned to account for effects of gain, transmit-receive frequency response and transducer beam patterns on echo data. The mean backscatter coefficient at 3 MHz in livers of 7 patients with fatty infiltration was 6.8 x 10(-3) cm(-1)sr(-1) compared to a mean of 0.5 x 10(-3) cm(-1)sr(-1) in healthy patients. Mean attenuation at 3 MHz was 2.54 dB/cm in fatty livers compared to 1.66 dB/cm in healthy patients. A total of 7 patients with end-stage liver disease (cirrhosis) had attenuation values similar to those in the healthy group, and their mean liver backscatter was somewhat greater than the mean backscatter for healthy livers. Quantitating both backscatter and attenuation should be considered for detecting fatty infiltration; additional processing methods are needed to differentiate cirrhotic changes on the basis of acoustic signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Powell, E. E., Cooksley, G. W. E., Hanson, R., Searle, J., Halliday, J. W., & Powell, L. W. (1990) · Hepatology · doi:10.1002/hep.1840110114 · Cited by 1,473
MITCHELL, D. G., KIM, I., CHANG, T. S., VINITSKI, S., SAPONARO, S. A., EHRLICH, S. M., RIFKIN, M. D., & RUBIN, R. (1991) · Investigative Radiology · doi:10.1097/00004424-199112000-00002 · Cited by 131
Cited by
Sasso, M., Beaugrand, M., de Ledinghen, V., Douvin, C., Marcellin, P., Poupon, R., Sandrin, L., & Miette, V. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.07.005 · Cited by 862
Quantitative Ultrasound in Soft Tissues
(2013) · Springer eBooks · doi:10.1007/978-94-007-6952-6 · Cited by 302
Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging
Cook, J. R., Bouchard, R. R., & Emelianov, S. Y. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003193 · Cited by 285
Sasso, M., Miette, V., Sandrin, L., & Beaugrand, M. (2012) · Clinics and Research in Hepatology and Gastroenterology · doi:10.1016/j.clinre.2011.08.001 · Cited by 283
Pirmoazen, A. M., Khurana, A., El Kaffas, A., & Kamaya, A. (2020) · Theranostics · doi:10.7150/thno.40249 · Cited by 165
Metadata
- Authors
- Lu, Z. F., Zagzebski, J. A., & Lee, F. T.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 1999-09
- Volume
- 25
- Issue
- 7
- Pages
- 1047-1054
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W1971791956
- Cited by
- 161
- References
- 2
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound backscatter and attenuation in human liver with diffuse disease. https://app.cochat.ai/papers/10.1016/s0301-5629(99)00055-1
- The paper
- Lu, Z. F., Zagzebski, J. A., & Lee, F. T. (1999). Ultrasound backscatter and attenuation in human liver with diffuse disease. Ultrasound in Medicine & Biology. https://doi.org/10.1016/s0301-5629(99)00055-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.