The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging
Open accessAbstract
In both photoacoustic (PA) and ultrasonic (US) imaging, overall image quality is influenced by the optical and acoustical properties of the medium. Consequently, with the increased use of combined PA and US (PAUS) imaging in preclinical and clinical applications, the ability to provide phantoms that are capable of mimicking desired properties of soft tissues is critical. To this end, gelatin-based phantoms were constructed with various additives to provide realistic acoustic and optical properties. Forty-micron, spherical silica particles were used to induce acoustic scattering, Intralipid(®) 20% IV fat emulsion was employed to enhance optical scattering and ultrasonic attenuation, while India Ink, Direct Red 81, and Evans blue dyes were utilized to achieve optical absorption typical of soft tissues. The following parameters were then measured in each phantom formulation: speed of sound, acoustic attenuation (from 6 to 22 MHz), acoustic backscatter coefficient (from 6 to 22 MHz), optical absorption (from 400 nm to 1300 nm), and optical scattering (from 400 nm to 1300 nm). Results from these measurements were then compared to similar measurements, which are offered by the literature, for various soft tissue types. Based on these comparisons, it was shown that a reasonably accurate tissue-mimicking phantom could be constructed using a gelatin base with the aforementioned additives. Thus, it is possible to construct a phantom that mimics specific tissue acoustical and/or optical properties for the purpose of PAUS imaging studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Determining the optical properties of turbid media by using the adding–doubling method
Prahl, S. A., van Gemert, M. J. C., & Welch, A. J. (1993) · Applied Optics · doi:10.1364/ao.32.000559 · Cited by 931
Optical Properties of Circulating Human Blood in the Wavelength Range 400–2500 nm
Roggan, A., Friebel, M., Dörschel, K., Hahn, A., & Müller, G. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429919 · Cited by 819
Optical properties of water in the near infrared*
Palmer, K. F., & Williams, D. (1974) · Journal of the Optical Society of America · doi:10.1364/josa.64.001107 · Cited by 709
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
Optical properties of intralipid: A phantom medium for light propagation studies
Flock, S. T., Jacques, S. L., Wilson, B. C., Star, W. M., & van Gemert, M. J. C. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120510 · Cited by 578
Phantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516
Cited by
Indocyanine Green J Aggregates in Polymersomes for Near-Infrared Photoacoustic Imaging
Changalvaie, B., Han, S., Moaseri, E., Scaletti, F., Truong, L., Caplan, R., Cao, A., Bouchard, R., Truskett, T. M., Sokolov, K. V., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b14519 · Cited by 93
Self-citation
Metadata
- Authors
- Cook, J. R., Bouchard, R. R., & Emelianov, S. Y.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-10-27
- Volume
- 2
- Issue
- 11
- Pages
- 3193
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2006535396
- Cited by
- 285
- References
- 21
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging. https://app.cochat.ai/papers/10.1364/boe.2.003193
- The paper
- Cook, J. R., Bouchard, R. R., & Emelianov, S. Y. (2011). Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging. Biomedical Optics Express. https://doi.org/10.1364/boe.2.003193
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.