Sensory stimulation (TENS): effects of parameter manipulation on mechanical pain thresholds in healthy human subjects
Abstract
Transcutaneous electrical nerve stimulation (TENS) is a popular form of electrostimulation. Despite an extensive research base, there remains no consensus regarding the parameter selection required to achieve maximal hypoalgesic effects. The aim of this double blind, sham-controlled study was to investigate the relative hypoalgesic effects of different TENS parameters (frequency, intensity and stimulation site) upon experimentally induced mechanical pain. Two hundred and forty participants were recruited in order to provide statistical analysis with 80% power at alpha = 0.05. Subjects were randomised to one of the six TENS groups, a control, and a sham TENS group (n = 30, 15 males, 15 females, per group). TENS groups differed in their combinations of stimulation; frequency (4 or 110 Hz), intensity ('to tolerance' or 'strong but comfortable') and stimulation site (segmental--over the distribution of the radial nerve or, extrasegmental--over acupuncture point 'gall bladder 34', or a combination of both segmental and extrasegmental). Pulse duration was fixed at 200 micros. Stimulation was delivered for 30 min and subjects were then monitored for a further 30 min. Mechanical pain threshold (MPT) was measured using a pressure algometer and taken from the first dorsal interosseous muscle of the dominant hand, ipsilateral to the stimulation site. MPT measures were taken, at baseline, and at 10-min intervals for 60 min. Difference scores were analysed using repeated measures and one-way ANOVA and relevant post hoc tests. Low frequency, high intensity, extrasegmental stimulation produced a rapid onset hypoalgesic effect, which increased during the stimulation period (P < 0.0005 control and sham) and was sustained for 30 min post-stimulation (P < 0.0005(control), P = 0.024(sham)). Whilst high frequency, 'strong but comfortable' intensity, segmental stimulation produced comparable hypoalgesic levels during stimulation, this effect was not sustained post-stimulation. Stimulation at a combination of the two sites did not produce any greater hypoalgesic effects. These results may have implications for the clinical use of sensory stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reliability of Clinical Pressure-Pain Algometric Measurements Obtained on Consecutive Days
Nussbaum, E. L., & Downes, L. (1998) · Physical Therapy · doi:10.1093/ptj/78.2.160 · Cited by 416
Cited by
Using Tens for Pain Control: The State of the Evidence
Vance, C. G., Dailey, D. L., Rakel, B. A., & Sluka, K. A. (2014) · Pain Management · doi:10.2217/pmt.14.13 · Cited by 480
Gender differences in pressure pain threshold in healthy humans
Chesterton, L. S., Barlas, P., Foster, N. E., Baxter, D. G., & Wright, C. C. (2003) · Pain · doi:10.1016/s0304-3959(02)00330-5 · Cited by 460
Self-citationArmijo-Olivo, S., Pitance, L., Singh, V., Neto, F., Thie, N., & Michelotti, A. (2016) · Physical Therapy · doi:10.2522/ptj.20140548 · Cited by 526
Bjordal, J. M., Johnson, M. I., Lopes-Martins, R. A., Bogen, B., Chow, R., & Ljunggren, A. E. (2007) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-8-51 · Cited by 329
Transcutaneous electrical nerve stimulation (TENS) versus placebo for chronic low-back pain
Khadilkar, A., Odebiyi, D. O., Brosseau, L., & Wells, G. A. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003008.pub3 · Cited by 304
Metadata
- Authors
- Chesterton, L. S., Barlas, P., Foster, N. E., Lundeberg, T., Wright, C. C., & Baxter, D. G.
- Venue
- Pain
- Published
- 2002-09
- Volume
- 99
- Issue
- 1
- Pages
- 253-262
- ISSN
- 0304-3959 (ISSN-L)
- OpenAlex
- W2125985133
- Cited by
- 184
- References
- 1
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensory stimulation (TENS): effects of parameter manipulation on mechanical pain thresholds in healthy human subjects. https://app.cochat.ai/papers/10.1016/s0304-3959(02)00118-5
- The paper
- Chesterton, L. S., Barlas, P., Foster, N. E., Lundeberg, T., Wright, C. C., & Baxter, D. G. (2002). Sensory stimulation (TENS): effects of parameter manipulation on mechanical pain thresholds in healthy human subjects. Pain. https://doi.org/10.1016/s0304-3959(02)00118-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.