Sensory stimulation (TENS): effects of parameter manipulation on mechanical pain thresholds in healthy human subjects
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Transcutaneous electrical nerve stimulation (TENS) is a popular form of electrostimulation. Despite an extensive research base, there remains no consensus regarding the parameter selection required to achieve maximal hypoalgesic effects. The aim of this double blind, sham-controlled study was to investigate the relative hypoalgesic effects of different TENS parameters (frequency, intensity and stimulation site) upon experimentally induced mechanical pain. Two hundred and forty participants were recruited in order to provide statistical analysis with 80% power at alpha = 0.05. Subjects were randomised to one of the six TENS groups, a control, and a sham TENS group (n = 30, 15 males, 15 females, per group). TENS groups differed in their combinations of stimulation; frequency (4 or 110 Hz), intensity ('to tolerance' or 'strong but comfortable') and stimulation site (segmental--over the distribution of the radial nerve or, extrasegmental--over acupuncture point 'gall bladder 34', or a combination of both segmental and extrasegmental). Pulse duration was fixed at 200 micros. Stimulation was delivered for 30 min and subjects were then monitored for a further 30 min. Mechanical pain threshold (MPT) was measured using a pressure algometer and taken from the first dorsal interosseous muscle of the dominant hand, ipsilateral to the stimulation site. MPT measures were taken, at baseline, and at 10-min intervals for 60 min. Difference scores were analysed using repeated measures and one-way ANOVA and relevant post hoc tests. Low frequency, high intensity, extrasegmental stimulation produced a rapid onset hypoalgesic effect, which increased during the stimulation period (P < 0.0005 control and sham) and was sustained for 30 min post-stimulation (P < 0.0005(control), P = 0.024(sham)). Whilst high frequency, 'strong but comfortable' intensity, segmental stimulation produced comparable hypoalgesic levels during stimulation, this effect was not sustained post-stimulation. Stimulation at a combination of the two sites did not produce any greater hypoalgesic effects. These results may have implications for the clinical use of sensory stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Melzack, R., & Wall, P. D. (1965) · Science · doi:10.1126/science.150.3699.971 · Cited by 11,090 · cited 6×
“The hypoalgesic effect of high frequency, low intensity segmental parameter combinations, which are not repeated extrasegmentally, is in agreement with the pain modulation effects proposed within the pain gate theory (Melzack and Wall, 1965).”
InfluentialCohen, J. (1992) · Psychological Bulletin · doi:10.1037//0033-2909.112.1.155 · Cited by 8,771
Melzack, R., & Wall, P. D. (1996) · Pain Forum · doi:10.1016/s1082-3174(96)80062-6 · Cited by 2,784
Diffuse noxious inhibitory controls (DNIC). I. Effects on dorsal horn convergent neurones in the rat
Le Bars, D., Dickenson, A. H., & Besson, J.-M. (1979) · Pain · doi:10.1016/0304-3959(79)90049-6 · Cited by 1,364 · cited 3×
“Keywords: Transcutaneous electrical nerve stimulation; Electrostimulation; Parameters; Mechanical pain; Humans”
Endogenous pain control mechanisms: Review and hypothesis
Basbaum, A. I., & Fields, H. L. (1978) · Annals of Neurology · doi:10.1002/ana.410040511 · Cited by 1,241
Fischer, A. A. (1987) · Pain · doi:10.1016/0304-3959(87)90089-3 · Cited by 958 · cited 4×
“MPT was taken as the amount of pressure required to elicit a sensation of pain distinct from pressure or discomfort (Fischer, 1987).”
InfluentialNeuroanatomy of the pain system and of the pathways that modulate pain
Willis, W. D., & Westlund, K. N. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199701000-00002 · Cited by 924 · cited 2×
“Wright and Sluka (2001) have also suggested that motor facilitation and sympathetic excitation are consistent with activation of the lateral periaqueductal grey matter, which may evoke analgesia as part of a defence response (Willis and Westlund, 1997).”
Le Bars, D., Dickenson, A. H., & Besson, J.-M. (1979) · Pain · doi:10.1016/0304-3959(79)90050-2 · Cited by 778 · cited 1×
“AL-TENS has also been associated with a counter irritation effect proposed by Le Bars et al. (1979a) with inhibition of neural pathways in the dorsal horn being mediated by the rostral ventral medulla (Basbaum and Fields, 1978).”
An Evidence-Based Resource for Pain Relief
McQuay, H., & Moore, R. A. (1998) · Medical Entomology and Zoology · Cited by 569
Reliability of Clinical Pressure-Pain Algometric Measurements Obtained on Consecutive Days
Nussbaum, E. L., & Downes, L. (1998) · Physical Therapy · doi:10.1093/ptj/78.2.160 · Cited by 416 · cited 1×
“The reliability of results obtained using a pressure algometer have been reported elsewhere (Nussbaum and Downes, 1998; Antonaci et al., 1992; Fischer, 1987).”
Wang, B., Tang, J., White, P. F., Naruse, R., Sloninsky, A., Kariger, R., Gold, J., & Wender, R. H. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199708000-00029 · Cited by 216 · cited 4×
“Data were analysed using the Statistical Package for Social Scientists (SPSS, Version 10) for Windows.”
InfluentialCarroll, D., Tramèr, M., McQuay, H., Nye, B., & Moore, A. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/77.6.798 · Cited by 213 · cited 2×
“, 2001; McQuay and Moore 1998; Carroll et al., 1996, 1997a,b; Flowerdew and Gadsby 1997; Reeve et al., 1996). Specific criticisms include: small sample sizes which lead to low statistical power, a lack of adequate blinding, no control Pain 99 (2002) 253–262”
Chung, J. M., Lee, K. H., Hori, Y., Endo, K., & Willis, W. D. (1984) · Pain · doi:10.1016/0304-3959(84)90005-8 · Cited by 200 · cited 2×
“…the individual, possibilities include the ‘diffuse noxious inhibitory control’ system proposed by Le Bars et al. (1979a,b) and the inhibition of the spinothalamic tract cells at a spinal cord level as a response to activation of the Aa, Ab and Ad fibres, a theory proposed by Chung et al. (1984).”
Nonpharmacological Treatments for Musculoskeletal Pain
Wright, A., & Sluka, K. A. (2001) · The Clinical Journal of Pain · doi:10.1097/00002508-200103000-00006 · Cited by 173 · cited 2×
“Wright and Sluka (2001) have also suggested that motor facilitation and sympathetic excitation are consistent with activation of the lateral periaqueductal grey matter, which may evoke analgesia as part of a defence response (Willis and Westlund, 1997).”
Chen, L., Tang, J., White, P. F., Sloninsky, A., Wender, R. H., Naruse, R., & Kariger, R. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199811000-00028 · Cited by 165
Hamza, M. A., White, P. F., Ahmed, H. E., & Ghoname, E.-S. A. (1999) · Anesthesiology · doi:10.1097/00000542-199911000-00012 · Cited by 164 · cited 2×
“Based on the previous results from the same group, Hamza et al. (1999) investigated the effects of stimulation frequency at a segmental site alone.”
Johnson, M. I., Ashton, C. H., & Thompson, J. W. (1991) · Pain · doi:10.1016/0304-3959(91)90089-g · Cited by 162 · cited 2×
“…electrode placement as one of the primary factors for poor patient response, and many authors concede that location of stimulation site is the least investigated parameter of TENS (Chen et al., 1998; Danziger et al., 1998; Walsh, 1996, 1997; Johnson et al., 1991b, 1992; Mannheimer, 1978).”
Transcutaneous electrical nerve stimulation (TENS) for chronic low-back pain
Milne, S., Welch, V, Brosseau, L., Saginur, M., Shea, B., Tugwell, P., & Wells, G. (2000) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003008 · Cited by 158
Descending pain inhibitory system involved in acupuncture analgesia
Takeshige, C., Sato, T., Mera, T., Hisamitsu, T., & Fang, J. (1992) · Brain Research Bulletin · doi:10.1016/0361-9230(92)90131-g · Cited by 157 · cited 1×
“…(the popularity of which may stem from promotional material distributed by manufacturers with TENS equipment) and there is tentative evidence to suggest that stimulation over such points is more effective than just dermatomal/ segmental stimulation (Chen et al., 1998; Takeshige et al., 1992a,b).”
Chen, X.-H., & Han, J. (1992) · European Journal of Pharmacology · doi:10.1016/0014-2999(92)90530-h · Cited by 138 · cited 1×
“AL-TENS pain modulation is associated with endogenous opiates, released via the descending inhibitory pathways in response to afferent activity in the A delta fibres (Chen et al., 1998; Sjolund and Eriksson, 1976). AL-TENS has also been associated with a counter irritation effect proposed by Le Bars et al. (1979a) wit…”
Transcutaneous electrical nerve stimulation in labour pain: a systematic review
Carroll, D., Tramèr, M., McQuay, H., Nye, B., & Moore, A. (1997) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1997.tb11039.x · Cited by 125 · cited 1×
“…available literature suggest that few of the published reports regarding TENS therapy meet acceptable methodological standards to underpin recommendations for clinical practice (Milne et al., 2001; McQuay and Moore 1998; Carroll et al., 1996, 1997a,b; Flowerdew and Gadsby 1997; Reeve et al., 1996).”
Tens: Clinical Applications and Related Theory
Walsh, D. M. J. (1997) · Medical Entomology and Zoology · Cited by 105
Walsh, D. M. J., Lowe, A. S., McCormack, K., Willer, J. C., Baxter, D. G., & Allen, J. M. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90170-8 · Cited by 101 · cited 3×
“…effect proposed by Ignelzi and Nyquist (1976) has been questioned by Janko and Trontelj (1980), other authors strongly suggest a peripheral component to TENS mediated hypoalgesia, which may be regulated by central mechanisms (Walsh et al., 1998; Levin and Hui-Chan, 1993; Francini et al., 1981).”
Self-citation(1999) · Complementary Therapies in Medicine · doi:10.1016/s0965-2299(99)80018-1 · Cited by 89
Walsh, D. M. J., Foster, N. E., Baxter, D. G., & Allen, J. M. (1995) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199505000-00004 · Cited by 81 · cited 2×
“The reliability of results obtained using a pressure algometer have been reported elsewhere (Nussbaum and Downes, 1998; Antonaci et al., 1992; Fischer, 1987).”
Self-citationIgnelzi, R. J., & Nyquist, J. K. (1976) · Journal of neurosurgery · doi:10.3171/jns.1976.45.2.0159 · Cited by 78 · cited 2×
“Although the contribution of altered peripheral nerve activity to the hypoalgesic effect proposed by Ignelzi and Nyquist (1976) has been questioned by Janko and Trontelj (1980), other authors strongly suggest a peripheral component to TENS mediated hypoalgesia, which may be regulated by central…”
Ashton, H., Ebenezer, I. S., Golding, J. F., & Thompson, J. W. (1984) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(84)90052-7 · Cited by 75 · cited 1×
“The authors, however, noted considerable individual variation in this response, which was also previously reported in a study from the same group (Ashton et al., 1984) and in the results presented here.”
Transcutaneous Electrical Nerve Stimulation (TENS): A Technology Assessment
Reeve, J., Menon, D., & Corabian, P. (1996) · International Journal of Technology Assessment in Health Care · doi:10.1017/s026646230000965x · Cited by 67 · cited 2×
“…available literature suggest that few of the published reports regarding TENS therapy meet acceptable methodological standards to underpin recommendations for clinical practice (Milne et al., 2001; McQuay and Moore 1998; Carroll et al., 1996, 1997a,b; Flowerdew and Gadsby 1997; Reeve et al., 1996).”
Transcutaneous electrical nerve stimulation: A microneurographic and perceptual study
Janko, M., & Trontelj, J. V. (1980) · Pain · doi:10.1016/0304-3959(80)90009-3 · Cited by 66 · cited 1×
“…the contribution of altered peripheral nerve activity to the hypoalgesic effect proposed by Ignelzi and Nyquist (1976) has been questioned by Janko and Trontelj (1980), other authors strongly suggest a peripheral component to TENS mediated hypoalgesia, which may be regulated by central…”
Central pain mechanisms: A new horizon in manual therapy
Shacklock, M. (1999) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60340-8 · Cited by 48 · cited 2×
“Data were analysed using the Statistical Package for Social Scientists (SPSS, Version 10) for Windows.”
Acupuncture-like transcutaneous electrical nerve stimulation (AL-TENS) in the management of pain
Johnson, M. I. (1998) · Physical Therapy Reviews · doi:10.1179/ptr.1998.3.2.73 · Cited by 43
Danziger, N., Rozenberg, S., Bourgeois, P., Charpentier, G., & Willer, J. C. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90299-4 · Cited by 40 · cited 2×
“…electrode placement as one of the primary factors for poor patient response, and many authors concede that location of stimulation site is the least investigated parameter of TENS (Chen et al., 1998; Danziger et al., 1998; Walsh, 1996, 1997; Johnson et al., 1991b, 1992; Mannheimer, 1978).”
Johnson, M. I., Hajela, V. K., Ashton, C. H., & Thompson, J. W. (1991) · Pain · doi:10.1016/0304-3959(91)90116-f · Cited by 33 · cited 2×
“…electrode placement as one of the primary factors for poor patient response, and many authors concede that location of stimulation site is the least investigated parameter of TENS (Chen et al., 1998; Danziger et al., 1998; Walsh, 1996, 1997; Johnson et al., 1991b, 1992; Mannheimer, 1978).”
Flowerdew, M., & Gadsby, J. G. (1997) · Complementary Therapies in Medicine · doi:10.1016/s0965-2299(97)80029-5 · Cited by 28 · cited 2×
“…available literature suggest that few of the published reports regarding TENS therapy meet acceptable methodological standards to underpin recommendations for clinical practice (Milne et al., 2001; McQuay and Moore 1998; Carroll et al., 1996, 1997a,b; Flowerdew and Gadsby 1997; Reeve et al., 1996).”
McDowell, B. C., McCormack, K., Walsh, D. M. J., Baxter, D. G., & Allen, J. M. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90051-5 · Cited by 26 · cited 2×
“This site has been used in previous studies (McDowell et al., 1999; Walsh et al., 1995, 1998) and was chosen for the following reasons: (a) to reflect clinical stimulation of acupoints, (b) allow stimulation within the same dermatome as experimental pain site, and (c) to keep the experimental pain…”
Self-citation
Cited by
Using Tens for Pain Control: The State of the Evidence
Vance, C. G., Dailey, D. L., Rakel, B. A., & Sluka, K. A. (2014) · Pain Management · doi:10.2217/pmt.14.13 · Cited by 480
Gender differences in pressure pain threshold in healthy humans
Chesterton, L. S., Barlas, P., Foster, N. E., Baxter, D. G., & Wright, C. C. (2003) · Pain · doi:10.1016/s0304-3959(02)00330-5 · Cited by 460
Self-citationArmijo-Olivo, S., Pitance, L., Singh, V., Neto, F., Thie, N., & Michelotti, A. (2016) · Physical Therapy · doi:10.2522/ptj.20140548 · Cited by 526
Bjordal, J. M., Johnson, M. I., Lopes-Martins, R. A., Bogen, B., Chow, R., & Ljunggren, A. E. (2007) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-8-51 · Cited by 329
Transcutaneous electrical nerve stimulation (TENS) versus placebo for chronic low-back pain
Khadilkar, A., Odebiyi, D. O., Brosseau, L., & Wells, G. A. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003008.pub3 · Cited by 304
Metadata
- Authors
- Chesterton, L. S., Barlas, P., Foster, N. E., Lundeberg, T., Wright, C. C., & Baxter, D. G.
- Venue
- Pain
- Published
- 2002-09
- Volume
- 99
- Issue
- 1
- Pages
- 253-262
- ISSN
- 0304-3959 (ISSN-L)
- OpenAlex
- W2125985133
- Cited by
- 184
- References
- 35
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.