Comparing different NTCP models that predict the incidence of radiation pneumonitis
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tolerance of normal tissue to therapeutic irradiation
Emami, B., Lyman, J., Brown, A., Cola, L., Goitein, M., Munzenrider, J. E., Shank, B., Solin, L. J., & Wesson, M. (1991) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(91)90171-y · Cited by 4,488
Randomization and Monte Carlo Methods in Biology.
Foutz, R. V., & Manly, B. F. J. (1992) · Journal of the American Statistical Association · doi:10.2307/2290299 · Cited by 1,621
- Statistical Models for Epidemiology
(2013) · Bayesian Methods in Epidemiology · doi:10.1201/b15382-9 · Cited by 1,346
Fitting of normal tissue tolerance data to an analytic function
Burman, C., Kutcher, G. J., Emami, B., & Goitein, M. (1991) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(91)90172-z · Cited by 1,249
Graham, M. V., Purdy, J. A., Emami, B., Harms, W., Bosch, W., Lockett, M. A., & Perez, C. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00183-2 · Cited by 1,223
Complication Probability as Assessed from Dose-Volume Histograms
Lyman, J. T. (1985) · Radiation Research · doi:10.2307/3576626 · Cited by 1,160
Statistical Methods in Epidemiology
(2012) · SpringerReference · doi:10.1007/springerreference_205629 · Cited by 1,124
Kutcher, G. J., & Burman, C. (1989) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(89)90972-3 · Cited by 912
Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients
Kwa, S. L. S., Lebesque, J. V., Theuws, J. C. M., Marks, L. B., Munley, M. T., Bentel, G., Oetzel, D., Spahn, U., Graham, M. V., Drzymala, R. E., et al. (1998) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00196-5 · Cited by 750
Self-citationComputer Intensive Methods for Testing Hypotheses: An Introduction
Evans, K. J., & Noreen, E. W. (1990) · Journal of the Operational Research Society · doi:10.2307/2582908 · Cited by 651
Cited by
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
Radiation Dose–Volume Effects in the Lung
Marks, L. B., Bentzen, S. M., Deasy, J. O., Kong, F.-M. (., Bradley, J. D., Vogelius, I. S., El Naqa, I., Hubbs, J. L., Lebesque, J. V., Timmerman, R. D., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.091 · Cited by 1,103
Self-citation21 years of Biologically Effective Dose
Fowler, J. F. (2010) · The British Journal of Radiology · doi:10.1259/bjr/31372149 · Cited by 639
4-dimensional computed tomography imaging and treatment planning
KEALL, P. (2004) · Seminars in Radiation Oncology · doi:10.1053/j.semradonc.2003.10.006 · Cited by 484
Mehta, V. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.03.047 · Cited by 410
Fatal pneumonitis associated with intensity-modulated radiation therapy for mesothelioma
Allen, A. M., Czerminska, M., Jänne, P. A., Sugarbaker, D. J., Bueno, R., Harris, J. R., Court, L., & Baldini, E. H. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.03.012 · Cited by 351
Kong, F.-M., Hayman, J. A., Griffith, K. A., Kalemkerian, G. P., Arenberg, D., Lyons, S., Turrisi, A., Lichter, A., Fraass, B., Eisbruch, A., et al. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.051 · Cited by 336
Self-citationA free program for calculating EUD-based NTCP and TCP in external beam radiotherapy
Gay, H. A., & Niemierko, A. (2007) · Physica Medica · doi:10.1016/j.ejmp.2007.07.001 · Cited by 330
Liao, Z. X., Komaki, R. R., Thames, H. D., Liu, H. H., Tucker, S. L., Mohan, R., Martel, M. K., Wei, X., Yang, K., Kim, E. S., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.02.032 · Cited by 282
Self-citationKong, F.-M., Ten Haken, R. K., Schipper, M., Frey, K. A., Hayman, J., Gross, M., Ramnath, N., Hassan, K. A., Matuszak, M., Ritter, T., et al. (2017) · JAMA Oncology · doi:10.1001/jamaoncol.2017.0982 · Cited by 224
“2 Using 3D CT-based conformal RT techniques, several radiation dose escalation studies have shown that doses much higher than 60–70 Gy are feasible[10-19].”
Self-citationMachine Learning Approaches for Predicting Radiation Therapy Outcomes: A Clinician's Perspective
Kang, J., Schwartz, R., Flickinger, J., & Beriwal, S. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.07.2286 · Cited by 215
“NTCP and tumor control probability (TCP) prediction models have conventionally focused on using dosimetric predictors alone (10, 21, 22).”
BackgroundBelderbos, J., Heemsbergen, W., Hoogeman, M., Pengel, K., Rossi, M., & Lebesque, J. (2005) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2005.03.021 · Cited by 194
“The envelope of this bundle confined the 95% confidence region [6,22,25].”
BackgroundSelf-citationRadioembolization of Hepatic Lesions from a Radiobiology and Dosimetric Perspective
Cremonesi, M., Chiesa, C., Strigari, L., Ferrari, M., Botta, F., Guerriero, F., De Cicco, C., Bonomo, G., Orsi, F., Bodei, L., et al. (2014) · Frontiers in Oncology · doi:10.3389/fonc.2014.00210 · Cited by 178
Liang, B., Yan, H., Tian, Y., Chen, X., Yan, L., Zhang, T., Zhou, Z., Wang, L., & Dai, J. (2019) · Frontiers in Oncology · doi:10.3389/fonc.2019.00269 · Cited by 178
Kong, F.-M., Haken, R. T., Eisbruch, A., & Lawrence, T. S. (2005) · Seminars in Oncology · doi:10.1053/j.seminoncol.2005.03.009 · Cited by 175
Metadata
- Authors
- Seppenwoolde, Y., Lebesque, J. V., de Jaeger, K., Belderbos, J. S. A., Boersma, L. J., Schilstra, C., Henning, G. T., Hayman, J. A., Martel, M. K., & Ten Haken, R. K.
- Venue
- International Journal of Radiation Oncology*Biology*Physics
- Publisher
- Elsevier BV
- Published
- 2003-03
- Volume
- 55
- Issue
- 3
- Pages
- 724-735
- ISSN
- 0360-3016 (ISSN-L)
- OpenAlex
- W2036018628
- Cited by
- 472
- References
- 23
- FWCI
- 26.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.