Design and applications of a self-aligning liquid junction-electrospray interface for capillary electrophoresis-mass spectrometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A simple self-aligning liquid junction-electrospray interface for coupling a capillary electrophoresis (CE) system to an atmospheric pressure ionization (API) mass spectrometer (CE-MS) was developed. In contrast to previous liquid junction interfaces, the self-aligning liquid junction interface simplifies the precise alignment of the CE capillary and the sprayer needle and uses a positive make-up flow. Several capillary CE-MS applications were run using both the self-aligning liquid junction interface and the widely used sheath flow interface for comparison purposes. The electrospray stability of the self-aligning liquid junction interface is consistently better even when non-volatile electrolyte solutions are used. At first, some band broadening was obtained with the self-aligning liquid junction interface. Experiments with different CE buffer systems suggested that this band broadening was caused by the materials used in constructing the interface. By using a more inert material for the sprayer needle, the self-aligning liquid junction exhibits excellent electrophoretic resolution, comparable sensitivity, and higher signal-to-noise ratios when run under the same conditions as the sheath flow interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, R. W., Easter, R. A., McKeith, F. K., Dalrymple, R. H., Maddock, H. M., & Bechtel, P. J. (1985) · Journal of Animal Science · doi:10.2527/jas1985.614905x · Cited by 139
Cited by
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
Capillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185
Glycomic analysis by capillary electrophoresis–mass spectrometry
Mechref, Y., & Novotny, M. V. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20196 · Cited by 105
CE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86
Metadata
- Authors
- Wachs, T., Sheppard, R. L., & Henion, J.
- Venue
- Journal of Chromatography B: Biomedical Sciences and Applications
- Publisher
- Elsevier BV
- Published
- 1996-10
- Volume
- 685
- Issue
- 2
- Pages
- 335-342
- ISSN
- 0378-4347 (ISSN-L)
- OpenAlex
- W1964101377
- Cited by
- 73
- References
- 1
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and applications of a self-aligning liquid junction-electrospray interface for capillary electrophoresis-mass spectrometry. https://app.cochat.ai/papers/10.1016/s0378-4347(96)00176-4
- The paper
- Wachs, T., Sheppard, R. L., & Henion, J. (1996). Design and applications of a self-aligning liquid junction-electrospray interface for capillary electrophoresis-mass spectrometry. Journal of Chromatography B: Biomedical Sciences and Applications. https://doi.org/10.1016/s0378-4347(96)00176-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.