Determination of retinoids in human serum, tocopherol and retinyl acetate in pharmaceuticals by RP-LC with electrochemical detection
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A liquid chromatography with a electrochemical detector method has been developed of the quantitative measurement for the three retinoids in human serum (13-cis and all-trans retinoic acid and retinol), as well as tocopherol acetate, retinyl acetate and retinol in pharmaceuticals. The detection cell consisted of a glassy carbon electrode held at 1.0 V versus an Ag/AgCl reference electrode. The maximum electrochemical signal was obtained with a supporting electrolyte containing 92% methanol 0.1 M acetate buffer (pH 4.72) as the mobile phase. The quantification limits are 0.5, 0.2, 0.4, 0.5, 0.8 and 0.8 ng for tocopherol acetate, all-trans-RA, 13-cis-RA, retinol, retinal and retinyl acetate, respectively. The electrooxidation process is applied for the simultaneous quantitative determination of retinoids in human serum. Comparison with results obtained from HPLC-UV shows agreement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“They can be affected by interference from matrix compounds and other analytes, and their sensitivity is strongly influenced by solvents, electrode type and flow characteristics [308,309,310].”
From Vitamin A Update: Forms, Sources, Kinetics, Detection, Function, Deficiency, Therapeutic Use and Toxicity (2021) · cites this paper as [308]
Citations
Cites
Arnaud, J., Fortis, I., Blachier, S., Kia, D., & Favier, A. (1991) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/0378-4347(91)80476-s · Cited by 328
Barua, A. B., & Olson, J. A. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00614-2 · Cited by 109
Frolik, C. A., Tavela, T. E., Peck, G. L., & Sporn, M. B. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90802-3 · Cited by 81
Wyss, R., & Bucheli, F. (1997) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00303-4 · Cited by 63
Puglisi, C. V., & Silva, J. A. F. D. (1978) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)85078-5 · Cited by 52
Sakhi, A. K., Gundersen, T. E., Ulven, S. M., Blomhoff, R., & Lundanes, E. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00676-1 · Cited by 51
MacCrehan, W. A., & Schönberger (1987) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/0378-4347(87)80092-0 · Cited by 46
Electrochemical Studies of β‐Carotene, all‐trans‐Retinal and all‐trans‐Retinol in Tetrahydrofuran
Park, S. (1978) · Journal of The Electrochemical Society · doi:10.1149/1.2131417 · Cited by 46
Kraft, J. C., Eckhoff, C., Kuhnz, W., Löfberg, B., & Nau, H. (1988) · Journal of Liquid Chromatography · doi:10.1080/01483918808069040 · Cited by 45
Meyer, E., Lambert, W. E., & Leenheer, A. P. D. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.1.48 · Cited by 34
Cited by
Carazo, A., Macáková, K., Matoušová, K., Krčmová, L. K., Protti, M., & Mladěnka, P. (2021) · Nutrients · doi:10.3390/nu13051703 · Cited by 461
Chromatographic analysis of endogenous retinoids in tissues and serum
Schmidt, C. K., Brouwer, A., & Nau, H. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00662-0 · Cited by 120
Chávez‐Servín, J. L., Castellote, A. I., & López‐Sabater, M. C. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.059 · Cited by 61
Andreoli, R., Manini, P., Poli, D., Bergamaschi, E., Mutti, A., & Niessen, W. M. A. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2288-0 · Cited by 56
New electrochemical sensor for direct quantification of vitamin K in human blood serum
Rostami–Javanroudi, S., & Babakhanian, A. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105716 · Cited by 34
Ziyatdinova, G. K., Giniyatova, E., & Budnikov, H. C. (2010) · Electroanalysis · doi:10.1002/elan.201000358 · Cited by 34
LC with Electrochemical Detection. Recent Application to Pharmaceuticals and Biological Fluids
Özkan, S. A. (2007) · Chromatographia · doi:10.1365/s10337-007-0223-9 · Cited by 29
Thangphatthanarungruang, J., Yakoh, A., Laocharoensuk, R., Chotsuwan, C., Chailapakul, O., & Siangproh, W. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114361 · Cited by 23
Thangphatthanarungruang, J., Ngamaroonchote, A., Laocharoensuk, R., Chotsuwan, C., & Siangproh, W. (2018) · Key engineering materials · doi:10.4028/www.scientific.net/kem.777.597 · Cited by 16
“Several analytical methods are available for the determination of fat-soluble vitamins such as capillary liquid chromatography [2], liquid chromatography with mass spectrometry [3] and highperformance liquid chromatography with ultraviolet [4], fluorescence [5], electrochemistry [6] and mass spectrometric detection [7…”
MethodAdsorptive stripping voltammetry in lipophilic vitamins determination
Sýs, M., Žabčíková, S., Červenka, L., & Vytřas, K. (2016) · Potravinarstvo Slovak Journal of Food Sciences · doi:10.5219/587 · Cited by 15
Quantification of retinoid concentrations in human serum and brain tumor tissues
Ali, R., Campos, B., Dyckhoff, G., Haefeli, W. E., Herold‐Mende, C. C., & Burhenne, J. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.003 · Cited by 14
Lee, H.-M., Kwak, B., Ahn, J., Jeong, S.-H., Shim, S., Kim, K., Yoon, T.-H., Leem, D., & Jeong, J. (2011) · Korean Journal for Food Science of Animal Resources · doi:10.5851/kosfa.2011.31.2.191 · Cited by 14
“Determination of fat soluble vitamins has been previously accomplished using HPLC with UV, fluorescence (FLD), electrochemical (ED), or evaporative light scattering (ELSD) detection methods (Chase et al., 1994; Podda et al., 1996; Speek et al., 1985; Wang and Wang, 2001; Warner and Mounts, 1990).”
MethodAnalysis of vitamin E derivatives in serum using coordinated ion spray mass spectrometry
Al‐Talla, Z. A., & Tolley, L. T. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2057 · Cited by 13
Asgher, M., Yaqoob, M., Nabi, A., Murtaza, G., Siddiqi, A. R., & Waseem, A. (2014) · International Journal of Analytical Chemistry · doi:10.1155/2014/109592 · Cited by 9
Machini, W. B. S., Enache, T. A., Jörge, S. M. A., & Oliveira‐Brett, A. M. (2016) · Electroanalysis · doi:10.1002/elan.201600206 · Cited by 9
Gong, G.-G., Zheng, J., Li, S., Bai, Y., & Feng, Y. (2022) · Talanta · doi:10.1016/j.talanta.2022.123474 · Cited by 9
Richelle, M., Tavazzi, I., & Fay, L. B. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(03)00360-x · Cited by 9
Hou, L., Yao, J., & Zhou, J. (2011) · Chromatographia · doi:10.1007/s10337-010-1903-4 · Cited by 9
Moulas, A. N., Zervos, I. A., Taitzoglou, I., Tsantarliotou, M. P., & Botsoglou, N. A. (2003) · Journal of Liquid Chromatography & Related Technologies · doi:10.1081/jlc-120017902 · Cited by 12
“Several reversed-phase chromatographic procedures have been described for the separation of vitamin A and its metabolites,([25]) which are mostly based on gradient elution([10,12,16,18,26,27]) and only a very few allow isocratic separation of the analytes.([3,13,17]) Since the majority of these are based on the 564 Mo…”
BackgroundIsotretinoína: perfis farmacológico, farmacocinético e analítico
Diniz, D. G. A., Lima, E. M., & Filho, N. R. A. (2002) · Revista Brasileira de Ciência do Solo · doi:10.1590/s1516-93322002000400004 · Cited by 8
da Silva, F. L. O., Tinoco, L. M. D. S., Ferreira, L. A. M., Malagutti, A. R., & Carneiro, G. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.10.018 · Cited by 6
Alghamdi, A. F. (2020) · Journal of King Saud University - Science · doi:10.1016/j.jksus.2020.05.005 · Cited by 5
Žabčíková, S., Nallbani, A., Sýs, M., Mikýsek, T., & Červenka, L. (2018) · Potravinarstvo Slovak Journal of Food Sciences · doi:10.5219/881 · Cited by 4
“high-performance liquid chromatography (HPLC) with UV or electrochemical detection (Wang and Wang, 2001; Almeida et al., 2009; Nada et al., 2010).”
BackgroundMethodDetermination of arotinoid acid in human plasma by liquid chromatography–tandem mass spectrometry
Deng, P., Chen, X., Tang, Y., Wang, Y., Zhang, H., & Zhong, D. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.07.017 · Cited by 2
teen. Multianalyte methods for analysis of the fat- and water-soluble vitamins
Eitenmiller, R. R., Landen, W. O., & Ye, L. (2016) · doi:10.1201/9781420009750-21
teen: Multianalyte methods for analysis of the fat- and water-soluble vitamins
(2007) · CRC Press eBooks · doi:10.1201/9781420009750.ch14
Topraksever, N., & Artuç, G. Ö. (2025) · İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi · doi:10.38079/igusabder.1589685
Metadata
- Authors
- Wang, L.-H., & Wang, J.-F.
- Affiliations
- Chia Nan University of Pharmacy and Science (TW)
- Corresponding author
- Wang, Lai-Hao
- Venue
- Journal of Pharmaceutical and Biomedical Analysis
- Publisher
- Elsevier BV
- Published
- 2001-07
- Volume
- 25
- Issue
- 5-6
- Pages
- 785-793
- ISSN
- 0731-7085 (ISSN-L)
- OpenAlex
- W2092273076
- Cited by
- 27
- References
- 18
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 1 · 2020: 3 · 2018: 2 · 2016: 3 · 2015: 1 · 2014: 1 · 2012: 1
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Pharmaceutical and Biomedical Analysis (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Council
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- retinoids, retinoic acid, retinol, retinyl acetate, tocopherol acetate, electrochemical detection, glassy carbon electrode, electrochemical oxidation, human serum, pharmaceutical analysis, reversed-phase liquid chromatography
- MeSH terms
- Retinyl Esters, Adult, Chromatography, High Pressure Liquid, Diterpenes, Electrochemistry, Female, Humans, Male, Retinoids, Sensitivity and Specificity, Spectrophotometry, Ultraviolet, Vitamin A, Vitamin E
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.