The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months
Open accessAbstract
OBJECTIVES The purpose of this study was to determine long-term effects of stent-based paclitaxel delivery on amount, rate and composition of neointimal thickening after stent implantation. BACKGROUND Paclitaxel prevents vascular smooth muscle cell proliferation and migration in vitro and in vivo. These actions, coupled with low solubility, make it a viable candidate for modulating vascular responses to injury and prolonged effects after local delivery. We asked whether local delivery of paclitaxel for a period of weeks from a stent coated with a bioerodible polymer could produce a sustained reduction in neointimal hyperplasia for up to six months after stenting. METHODS Stainless steel stents were implanted in the iliac arteries of rabbits after endothelial denudation. Stents were uncoated or coated with a thin layer of poly(lactide-co-sigma-caprolactone) copolymer alone or containing paclitaxel, 200 microg. RESULTS Paclitaxel release in vitro followed first-order kinetics for two months. Tissue responses were examined 7, 28, 56 or 180 days after implantation. Paclitaxel reduced intimal and medial cell proliferation three-fold seven days after stenting and virtually eliminated later intimal thickening. Six months after stenting, long after drug release and polymer degradation were likely complete, neointimal area was two-fold lower in paclitaxel-releasing stents. Tissue responses in paclitaxel-treated vessels included incomplete healing, few smooth muscle cells, late persistence of macrophages and dense fibrin with little collagen. CONCLUSIONS Poly(lactide-co-sigma-caprolactone) copolymer-coated stents permit sustained paclitaxel delivery in a manner that virtually abolishes neointimal hyperplasia for months after stent implantation, long after likely completion of drug delivery and polymer degradation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rowinsky, E. K., & Donehower, R. C. (1995) · New England Journal of Medicine · doi:10.1056/nejm199504133321507 · Cited by 1,924
Cited by
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Pathological Analysis of Local Delivery of Paclitaxel Via a Polymer-Coated Stent
Farb, A., Heller, P. F., Shroff, S., Cheng, L., Kolodgie, F. D., Carter, A. J., Scott, D. S., Froehlich, J., & Virmani, R. (2001) · Circulation · doi:10.1161/hc3001.092037 · Cited by 423
Metadata
- Authors
- Drachman, D. E., Edelman, E. R., Seifert, P., Groothuis, A. R., Bornstein, D. A., Kamath, K. R., Palasis, M., Yang, D., Nott, S. H., & Rogers, C.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2000-12
- Volume
- 36
- Issue
- 7
- Pages
- 2325-2332
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2159629829
- Cited by
- 286
- References
- 1
- FWCI
- 24.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months. https://app.cochat.ai/papers/10.1016/s0735-1097(00)01020-2
- The paper
- Drachman, D. E., Edelman, E. R., Seifert, P., Groothuis, A. R., Bornstein, D. A., Kamath, K. R., Palasis, M., Yang, D., Nott, S. H., & Rogers, C. (2000). Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(00)01020-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.