Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVES The purpose of this study was to determine long-term effects of stent-based paclitaxel delivery on amount, rate and composition of neointimal thickening after stent implantation. BACKGROUND Paclitaxel prevents vascular smooth muscle cell proliferation and migration in vitro and in vivo. These actions, coupled with low solubility, make it a viable candidate for modulating vascular responses to injury and prolonged effects after local delivery. We asked whether local delivery of paclitaxel for a period of weeks from a stent coated with a bioerodible polymer could produce a sustained reduction in neointimal hyperplasia for up to six months after stenting. METHODS Stainless steel stents were implanted in the iliac arteries of rabbits after endothelial denudation. Stents were uncoated or coated with a thin layer of poly(lactide-co-sigma-caprolactone) copolymer alone or containing paclitaxel, 200 microg. RESULTS Paclitaxel release in vitro followed first-order kinetics for two months. Tissue responses were examined 7, 28, 56 or 180 days after implantation. Paclitaxel reduced intimal and medial cell proliferation three-fold seven days after stenting and virtually eliminated later intimal thickening. Six months after stenting, long after drug release and polymer degradation were likely complete, neointimal area was two-fold lower in paclitaxel-releasing stents. Tissue responses in paclitaxel-treated vessels included incomplete healing, few smooth muscle cells, late persistence of macrophages and dense fibrin with little collagen. CONCLUSIONS Poly(lactide-co-sigma-caprolactone) copolymer-coated stents permit sustained paclitaxel delivery in a manner that virtually abolishes neointimal hyperplasia for months after stent implantation, long after likely completion of drug delivery and polymer degradation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rowinsky, E. K., & Donehower, R. C. (1995) · New England Journal of Medicine · doi:10.1056/nejm199504133321507 · Cited by 1,924 · cited 2×
“Paclitaxel has diverse mechanisms of action, including microtubule stabilization, arrest of cell mitosis, retardation of cell migration and immunomodulation (6) and has been reported to reduce vascular cell proliferation and migration in vitro and in vivo (7–11).”
BackgroundSchwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Axel, D. I., Kunert, W., Göggelmann, C., Oberhoff, M., Herdeg, C., Küttner, A., Wild, D. H., Brehm, B. R., Riessen, R., Köveker, G., et al. (1997) · Circulation · doi:10.1161/01.cir.96.2.636 · Cited by 784
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543
Self-citationSerruys, P. W., Emanuelsson, H., van der Giessen, W., Lunn, A. C., Kiemeney, F., Macaya, C., Rutsch, W., Heyndrickx, G., Suryapranata, H., Legrand, V., et al. (1996) · Circulation · doi:10.1161/01.cir.93.3.412 · Cited by 408
Late Coronary Occlusion After Intracoronary Brachytherapy
Costa, M. A., Sabaté, M., van der Giessen, W. J., Kay, I. P., Cervinka, P., Ligthart, J. M. R., Serrano, P., Coen, V. L. M. A., Levendag, P. C., & Serruys, P. W. (1999) · Circulation · doi:10.1161/01.cir.100.8.789 · Cited by 389
Lincoff, A. M., Furst, J. G., Ellis, S. G., Tuch, R. J., & Topol, E. J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00584-0 · Cited by 282
Taxol inhibits neointimal smooth muscle cell accumulation after angioplasty in the rat.
Sollott, S. J., Cheng, L., Pauly, R. R., Jenkins, G. M., Monticone, R. E., Kuzuya, M., Froehlich, J. P., Crow, M. T., Lakatta, E. G., & Rowinsky, E. K. (1995) · Journal of Clinical Investigation · doi:10.1172/jci117867 · Cited by 253
Rogers, C., Edelman, E. R., & Simon, D. I. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.17.10134 · Cited by 239
Self-citation
Cited by
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Vascular Responses to Drug Eluting Stents: Importance of Delayed Healing
Finn, A. V., Nakazawa, G., Joner, M., Kolodgie, F. D., Mont, E. K., Gold, H. K., & Virmani, R. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.144220 · Cited by 900
Grube, E., Silber, S., Hauptmann, K. E., Mueller, R., Buellesfeld, L., Gerckens, U., & Russell, M. E. (2003) · Circulation · doi:10.1161/01.cir.0000047700.58683.a1 · Cited by 865
Sankara Narayanan, T. S. N., Park, I. S., & Lee, M. H. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.08.002 · Cited by 639
Finn, A. V., Kolodgie, F. D., Harnek, J., Guerrero, L. J., Acampado, E., Tefera, K., Skorija, K., Weber, D. K., Gold, H. K., & Virmani, R. (2005) · Circulation · doi:10.1161/circulationaha.104.508937 · Cited by 556
Molecular Basis of Restenosis and Drug-Eluting Stents
Costa, M. A., & Simon, D. I. (2005) · Circulation · doi:10.1161/01.cir.0000163587.36485.a7 · Cited by 510
Physiological Transport Forces Govern Drug Distribution for Stent-Based Delivery
Hwang, C.-W., Wu, D., & Edelman, E. R. (2001) · Circulation · doi:10.1161/hc3101.092214 · Cited by 426
Self-citationPathological Analysis of Local Delivery of Paclitaxel Via a Polymer-Coated Stent
Farb, A., Heller, P. F., Shroff, S., Cheng, L., Kolodgie, F. D., Carter, A. J., Scott, D. S., Froehlich, J., & Virmani, R. (2001) · Circulation · doi:10.1161/hc3001.092037 · Cited by 423
New Frontiers in Cardiology: Drug-Eluting Stents: Part I
Sousa, J. E., Serruys, P. W., & Costa, M. A. (2003) · Circulation · doi:10.1161/01.cir.0000069330.41022.90 · Cited by 349
Drug-Eluting Stents in Preclinical Studies: Recommended Evaluation From a Consensus Group
Schwartz, R. S., Edelman, E. R., Carter, A., Chronos, N., Rogers, C., Robinson, K. A., Waksman, R., Weinberger, J., Wilensky, R. L., Jensen, D. N., et al. (2002) · Circulation · doi:10.1161/01.cir.0000033485.20594.6f · Cited by 291
Self-citationCoronary Artery Aneurysms: A Review of the Epidemiology, Pathophysiology, Diagnosis, and Treatment
Abou Sherif, S., Ozden Tok, O., Taşköylü, Ö., Goktekin, O., & Kilic, I. D. (2017) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2017.00024 · Cited by 286
Preclinical restenosis models and drug-eluting stents
Schwartz, R. S., Chronos, N. A., & Virmani, R. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.060 · Cited by 251
Drug-eluting stents: caution and concerns for long-term outcome
Virmani, R., Farb, A., Guagliumi, G., & Kolodgie, F. D. (2004) · Coronary Artery Disease · doi:10.1097/00019501-200409000-00003 · Cited by 231
Drug-eluting stents: results, promises and problems
van der Hoeven, B. L., Pires, N. M. M., Warda, H. M., Oemrawsingh, P. V., van Vlijmen, B. J. M., Quax, P. H. A., Schalij, M. J., van der Wall, E. E., & Jukema, J. W. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.01.021 · Cited by 202
“Later, some polymers were found to be biologically inert and stable for at least six months or biodegradable without increased proliferative response.(24,25) New developments are biocompatible and inorganic coatings.”
BackgroundThe Taxus™ drug-eluting stent: A new paradigm in controlled drug delivery
Kamath, K. R., Barry, J. J., & Miller, K. M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.01.023 · Cited by 174
Self-citationLocal Drug Delivery via a Coronary Stent With Programmable Release Pharmacokinetics
Finkelstein, A., McClean, D., Kar, S., Takizawa, K., Varghese, K., Baek, N., Park, K., Fishbein, M. C., Makkar, R., Litvack, F., et al. (2003) · Circulation · doi:10.1161/01.cir.0000050367.65079.71 · Cited by 170
Coated Stents for the Prevention of Restenosis: Part I
Babapulle, M. N., & Eisenberg, M. J. (2002) · Circulation · doi:10.1161/01.cir.0000038982.49640.70 · Cited by 161
Release profiles in drug-eluting stents: Issues and uncertainties
Venkatraman, S., & Boey, F. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.04.022 · Cited by 158
Metadata
- Authors
- Drachman, D. E., Edelman, E. R., Seifert, P., Groothuis, A. R., Bornstein, D. A., Kamath, K. R., Palasis, M., Yang, D., Nott, S. H., & Rogers, C.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2000-12
- Volume
- 36
- Issue
- 7
- Pages
- 2325-2332
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2159629829
- Cited by
- 286
- References
- 24
- FWCI
- 24.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.