Mortality, morbidity, and quality of life after circumferential pulmonary vein ablation for atrial fibrillation
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVES This study was designed to investigate the potential of circumferential pulmonary vein (PV) ablation for atrial fibrillation (AF) to maintain sinus rhythm (SR) over time, thus reducing mortality and morbidity while enhancing quality of life (QoL). BACKGROUND Circumferential PV ablation is safe and effective, but the long-term outcomes and its impact on QoL have not been assessed or compared with those for medical therapy. METHODS We examined the clinical course of 1,171 consecutive patients with symptomatic AF who were referred to us between January 1998 and March 2001. The 589 ablated patients were compared with the 582 who received antiarrhythmic medications for SR control. The QoL of 109 ablated and 102 medically treated patients was measured with the SF-36 survey. RESULTS Median follow-up was 900 days (range 161 to 1,508 days). Kaplan-Meier analysis showed observed survival for ablated patients was longer than among patients treated medically (p < 0.001), and not different from that expected for healthy persons of the same gender and calendar year of birth (p = 0.55). Cox proportional-hazards model revealed in the ablation group hazard ratios of 0.46 (95% confidence interval [CI], 0.31 to 0.68; p < 0.001) for all-cause mortality, of 0.45 (95% CI, 0.31 to 0.64; p < 0.001) for morbidities mainly due to heart failure and ischemic cerebrovascular events, and of 0.30 (95% CI, 0.24 to 0.37; p < 0.001) for AF recurrence. Ablated patients' QoL, different from patients treated medically, reached normative levels at six months and remained unchanged at one year. CONCLUSIONS Pulmonary vein ablation improves mortality, morbidity, and QoL as compared with medical therapy. Our findings pave the way for randomized trials to prospect a wider application of ablation therapy for AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Van Gelder, I. C., Hagens, V. E., Bosker, H. A., Kingma, J. H., Kamp, O., Kingma, T., Said, S. A., Darmanata, J. I., Timmermans, A. J. M., Tijssen, J. G. P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa021375 · Cited by 2,359
Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., Salvati, A., Dicandia, C., Mazzone, P., Santinelli, V., et al. (2000) · Circulation · doi:10.1161/01.cir.102.21.2619 · Cited by 1,358
Self-citationThe Italian SF-36 Health Survey
Apolone, G., & Mosconi, P. (1998) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(98)00094-8 · Cited by 1,148 · cited 4×
“Separate multivariate models, adjusted for relevant baseline characteristics listed in Figure 3, were used to assess changes in SF-36 physical and mental summary component scores, and the independent relationship of treatment and AF recurrence with QoL.”
MethodInfluentialAmiodarone to Prevent Recurrence of Atrial Fibrillation
Roy, D., Talajic, M., Dorian, P., Connolly, S., Eisenberg, M. J., Green, M., Kus, T., Lambert, J., Dubuc, M., Gagné, P., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003303421302 · Cited by 1,143
Hohnloser, S. H., Kuck, K.-H., & Lilienthal, J. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03230-x · Cited by 1,134
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112 · cited 1×
“This may explain why the success rates of this ablative technique in both arrhythmia types are higher than in mapping-guided strategies isolating PVs at their ostia, without excluding any atrial myocardium (14).”
ResultPappone, C., Oreto, G., Rosanio, S., Vicedomini, G., Tocchi, M., Gugliotta, F., Salvati, A., Dicandia, C., Calabrò, M. P., Mazzone, P., et al. (2001) · Circulation · doi:10.1161/hc4601.098517 · Cited by 863 · cited 5×
“This purely anatomic approach yields either an atriovenous electrical disconnection, as demonstrated by elimination of PV ostial potentials and absence of discrete electrical activity inside the lesion during pacing outside the ablation line, or a profound atrial electroanatomic remodeling, as expressed by voltage aba…”
BackgroundMethodInfluentialSelf-citation
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
“The incidence of thromboembolism associated with AF ablation is reported to be between 0% and 7% [45, 90, 116, 207, 379, 386, 437, 605, 606].”
BackgroundSelf-citation
Metadata
- Authors
- Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., Tortoriello, V., Sala, S., Zangrillo, A., Crescenzi, G., Benussi, S., & Alfieri, O.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 42
- Issue
- 2
- Pages
- 185-197
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2572139654
- Cited by
- 781
- References
- 21
- FWCI
- 51.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.