CoChat

A reference data base for multilead electrocardiographic computer measurement programs

Open access
Willems, Jos L., Arnaud, Pierre, Van Bemmel, Jan H., Bourdillon, Peter J., Degani, Rosanna, Denis, Bernard, Graham, Ian, Harms, Frits M.A., Macfarlane, Peter W., Mazzocca, Gianfranco, Meyer, Jürgen, Zywietz, Christoph · 1987 · Journal of the American College of Cardiology
Cited by 156

The DOI matches its Crossref record.

Abstract

In an effort to standardize and evaluate the performance of electrocardiographic computer measurement programs, a 15 lead reference library has been developed based on simultaneously recorded standard 12 lead and orthogonal XYZ lead data. A set of 250 electrocardiograms (ECGs) with selected abnormalities was analyzed by a group of five referee cardiologists and 11 different 12 lead and 6 XYZ computer programs. Attention was focused on the exact determination of the onsets and offsets of P, QRS and T waves. The referees performed their task on highly amplified, selected complexes from the library in a two round process. Median results of the referees coincided best with the median derived from all programs. An analysis of stability proved that the combined program median was a robust reference. However, some individual program results were widely divergent. Paired t tests demonstrated earlier onset for P and QRS (p less than 0.001), as well as later offset for P and T waves in the median 12 lead than in the XYZ results. Significant differences also existed among results obtained by programs analyzing all standard ECG leads at one time, the so-called multilead programs, and those obtained by the conventional standard three lead analysis programs. As a consequence, the derived P, PR, QRS and QT interval measurements varied quite widely among the various programs. Significant differences were also observed among measurements of Q, R and S duration. Some programs showed Q waves that were on the average 6 ms (p less than 0.001) longer than those of others. This may significantly influence diagnostic performance.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0735-1097(87)80136-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 156

Metadata

Authors
Willems, J. L., Arnaud, P., Van Bemmel, J. H., Bourdillon, P. J., Degani, R., Denis, B., Graham, I., Harms, F. M. A., Macfarlane, P. W., Mazzocca, G., Meyer, J., & Zywietz, C.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1987-12
Volume
10
Issue
6
Pages
1313-1321
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2037212218
Cited by
156
References
0
FWCI
1.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A reference data base for multilead electrocardiographic computer measurement programs. https://app.cochat.ai/papers/10.1016/s0735-1097(87)80136-5
The paper
Willems, J. L., Arnaud, P., Van Bemmel, J. H., Bourdillon, P. J., Degani, R., Denis, B., Graham, I., Harms, F. M. A., Macfarlane, P. W., Mazzocca, G., Meyer, J., & Zywietz, C. (1987). A reference data base for multilead electrocardiographic computer measurement programs. Journal of the American College of Cardiology. https://doi.org/10.1016/s0735-1097(87)80136-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.