Relative roles of microdamage and microfracture in the mechanical behavior of trabecular bone
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Compared to trabecular microfracture, the biomechanical consequences of the morphologically more subtle trabecular micro‐damage are unclear but potentially important because of its higher incidence. A generic three‐dimensional finite element model of the trabecular bone microstructure was used to investigate the relative biomechanical roles of these damage categories on reloading elastic modulus after simulated overloads to various strain levels. Microfractures of individual trabeculae were modeled using a maximum fracture strain criterion, for three values of fracture strain (2%, 8%, and 35%). Microdamage within the trabeculae was modeled using a strain‐based modulus reduction rule based on cortical bone behavior. When combining the effects of both microdamage and microfracture, the model predicted reductions in apparent modulus upon reloading of over 60% at an applied apparent strain of 2%, in excellent agreement with previously reported experimental data. According to the model, up to 80% of the trabeculae developed microdamage at 2% apparent strain, and between 2% and 10% of the trabeculae were fractured, depending on which fracture strain was assumed. If microdamage could not occur but microfracture could, good agreement with the experimental data only resulted if the trabecular hard tissue had a fracture strain of 2%. However, a high number of fractures (10% of the trabeculae) would need to occur for this case, and this has not been observed in published damage morphology studies. We conclude therefore that if the damage behavior of trabecular hard tissue is similar to that of cortical bone, then extensive microdamage is primarily responsible for the large loss in apparent mechanical properties that can occur with overloading of trabecular bone. © 2001 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
McCalden, R. W., McGeough, J. A., Barker, M. B., & Court-Brown, C. M. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199308000-00009 · Cited by 709
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationCyclic mechanical property degradation during fatigue loading of cortical bone
Pattin, C. A., Caler, W. E., & Carter, D. R. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00156-1 · Cited by 442
A comparison of the fatigue behavior of human trabecular and cortical bone tissue
Choi, K., & Goldstein, S. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90051-2 · Cited by 247
Failure mechanisms in human vertebral cancellous bone
Fyhrie, D. P., & Schaffler, M. B. (1994) · Bone · doi:10.1016/8756-3282(94)90900-8 · Cited by 215
Mechanical behavior of human trabecular bone after overloading
Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170308 · Cited by 155
Self-citationAge-related differences in post-yield damage in human cortical bone. Experiment and model
Courtney, A. C., Hayes, W. C., & Gibson, L. J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)84542-8 · Cited by 131
Cited by
Mechanistic fracture criteria for the failure of human cortical bone
Nalla, R. K., Kinney, J. H., & Ritchie, R. O. (2003) · Nature Materials · doi:10.1038/nmat832 · Cited by 730
Bone quality: where do we go from here?
Bouxsein, M. L. (2003) · Osteoporosis International · doi:10.1007/s00198-003-1489-x · Cited by 264
Fracture in human cortical bone: local fracture criteria and toughening mechanisms
Nalla, R. K., Stölken, J. S., Kinney, J. H., & Ritchie, R. O. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.010 · Cited by 260
“…although models for bone fracture are invariably based on the concept of a strain-controlled critical fracture event (e.g., Keaveny et al., 1994; Ford and Keaveny, 1996; Yeh and Keaveny, 2001), until recently (Nalla et al., 2003a) there has been no experimental evidence to verify this hypothesis.”
BackgroundTrabecular bone microdamage and microstructural stresses under uniaxial compression
Nagaraja, S., Couse, T. L., & Guldberg, R. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.013 · Cited by 220
“Microfractures, the most severe case of bone damage, are considered the end result of microdamage accumulation (Yeh and Keaveny, 2001).”
BackgroundBone mass and architecture determination: state of the art
Griffith, J. F., & Genant, H. K. (2008) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2008.07.003 · Cited by 126
Metadata
- Authors
- Yeh, O. C., & Keaveny, T. M.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2001-11
- Volume
- 19
- Issue
- 6
- Pages
- 1001-1007
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2090679788
- Cited by
- 93
- References
- 9
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relative roles of microdamage and microfracture in the mechanical behavior of trabecular bone. https://app.cochat.ai/papers/10.1016/s0736-0266(01)00053-5
- The paper
- Yeh, O. C., & Keaveny, T. M. (2001). Relative roles of microdamage and microfracture in the mechanical behavior of trabecular bone. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(01)00053-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.