Corneal ectasia induced by laser in situ keratomileusis
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE: To identify factors that can lead to corneal ectasia after laser in situ keratomileusis (LASIK). SETTING: University refractive surgery center. METHODS: In this retrospective study, the charts of all patients (2873 eyes) who had LASIK between May 1995 and November 1999 were reviewed. Fourteen patients (19 eyes, 0.66%) developed post-LASIK ectasia. The mean follow-up was 16.32 months (range 6 to 42 months). RESULTS: No patient with an attempted correction less than 8.00 diopters or a residual corneal bed thickness greater than 325 microm experienced post-LASIK ectasia. There was a statistically significant positive correlation between corneal residual bed thickness and increasing patient age. CONCLUSION: Despite the limitations of the small sample size, the study's results suggest that parameters besides residual corneal bed thickness (eg, age, attempted correction) may have to be considered to avoid post-LASIK ectasia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complications of laser in situ keratomileusis for the correction of myopia
Stulting, R. D., Carr, J. D., Thompson, K. P., Waring, G. O., Wiley, W. M., & Walker, J. G. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90000-3 · Cited by 495
Computer-Assisted Corneal Topography in Keratoconus
Rabinowitz, Y. S., & McDonnell, P. J. (1989) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19891101-10 · Cited by 395
The Cornea is Not a Piece of Plastic
Roberts, C. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000701-03 · Cited by 326
Laser in situ keratomileusis: Literature review of a developing technique
Farah, S. G., Azar, D. T., Gurdal, C., & Wong, J. (1998) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(98)80056-4 · Cited by 281
Keratocyte apoptosis: implications on corneal wound healing, tissue organization, and disease.
Wilson, S. E., & Kim, W. J. (1998) · PubMed · Cited by 241
Thalmann‐Goetsch, A., Engelmann, K., & Bednarz, J. (1997) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.1997.tb00134.x · Cited by 19
Cited by
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
Risk Assessment for Ectasia after Corneal Refractive Surgery
Randleman, J. B., Woodward, M., Lynn, M. J., & Stulting, R. D. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.03.073 · Cited by 739
Risk factors and prognosis for corneal ectasia after LASIK
Randleman, J. B., Russell, B., Ward, M. A., Thompson, K. P., & Stulting, R. D. (2003) · Ophthalmology · doi:10.1016/s0161-6420(02)01727-x · Cited by 690
Ocular Rigidity in Living Human Eyes
Pallikaris, I. G., Kymionis, G. D., Ginis, H. S., Kounis, G. A., & Tsilimbaris, M. K. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0162 · Cited by 301
Self-citationRisk Factors for Progression to Penetrating Keratoplasty in Patients With Keratoconus
Reeves, S. W., Stinnett, S., Adelman, R. A., & Afshari, N. A. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.05.029 · Cited by 290
Metadata
- Authors
- Pallikaris, I. G., Kymionis, G. D., & Astyrakakis, N. I.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2001-11
- Volume
- 27
- Issue
- 11
- Pages
- 1796-1802
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2015313300
- Cited by
- 412
- References
- 6
- FWCI
- 12.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›