The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The Cornea is Not a Piece of Plastic
Abstract
nd hyperopia. His geometric approach can be thought of as a "shapesubtraction " model, where tissue of an appropriate profile is simply "subtracted" using an excimer laser to produce the desired surface curvature. Essentially, the cornea is treated like a piece of plastic to be sculpted into the ideal surface shape. The Munnerlyn approach, combined with empirical experience, has been relatively successful in correcting spherical and cylindrical errors for the majority of patients treated to date. However, only 50% to 85% achieve 20/20, despite greater than 90% of patients being "satisfied." In addition, significant postoperative optical aberrations are produced using conventional algorithms 2-4 , encouraging the development of aberration-reducing ablation profiles. To improve the percentage of patients who achieve postoperative visual acuity of 20/20 or better, as well as to minimize optical aberrations, it is important to examine critically our current conceptual mod
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photorefractive keratectomy: A technique for laser refractive surgery
Munnerlyn, C. R., Koons, S. J., & Marshall, J. (1988) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(88)80063-4 · Cited by 763
Corneal Aberrations and Visual Performance After Radial Keratotomy
Applegate, R. A., Howland, H. C., Sharp, R. P., Cottingham, A. J., & Yee, R. W. (1998) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19980701-05 · Cited by 307
Reinstein, D. Z., Silverman, R. H., Raevsky, T., Simoni, G. J., Lloyd, H. O., Najafi, D. J., Rondeau, M. J., & Coleman, D. J. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000701-04 · Cited by 203
Cited by
Biomechanics and wound healing in the cornea
Dupps, W. J., & Wilson, S. E. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.03.015 · Cited by 510
Corneal ectasia induced by laser in situ keratomileusis
Pallikaris, I. G., Kymionis, G. D., & Astyrakakis, N. I. (2001) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(01)01090-2 · Cited by 412
Brillouin Optical Microscopy for Corneal Biomechanics
Scarcelli, G., Pineda, R., & Yun, S. H. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8281 · Cited by 354
Ocular Biomechanics and Biotransport
Ethier, C. R., Johnson, M., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 288
Whitford, C., Studer, H., Boote, C., Meek, K. M., & Elsheikh, A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.11.006 · Cited by 94
Metadata
- Authors
- Roberts, C.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2000-07
- Volume
- 16
- Issue
- 4
- Pages
- 407-413
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2157560767
- Cited by
- 326
- References
- 3
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Cornea is Not a Piece of Plastic. https://app.cochat.ai/papers/10.3928/1081-597x-20000701-03
- The paper
- Roberts, C. (2000). The Cornea is Not a Piece of Plastic. Journal of Refractive Surgery. https://doi.org/10.3928/1081-597x-20000701-03
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.