The diagnostic odds ratio: a single indicator of test performance
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Diagnostic testing can be used to discriminate subjects with a target disorder from subjects without it. Several indicators of diagnostic performance have been proposed, such as sensitivity and specificity. Using paired indicators can be a disadvantage in comparing the performance of competing tests, especially if one test does not outperform the other on both indicators. Here we propose the use of the odds ratio as a single indicator of diagnostic performance. The diagnostic odds ratio is closely linked to existing indicators, it facilitates formal meta-analysis of studies on diagnostic test performance, and it is derived from logistic models, which allow for the inclusion of additional variables to correct for heterogeneity. A disadvantage is the impossibility of weighing the true positive and false positive rate separately. In this article the application of the diagnostic odds ratio in test evaluation is illustrated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It can be shown35 that LR+ is independent of the class prior and can be alternatively expressed as(Equation 4)LR+=P(evidence of pathogenicity|vis pathogenic)P(evidence of pathogenicity|vis benign)”
From Calibration of computational tools for missense variant pathogenicity classification and ClinGen recommendations for PP3/BP4 criteria (2022) · cites this paper as [35]
Citations
Cites
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 2×
“The area under the curve obtained (AUC) can subsequently be calculated as an alternative single indicator of test performance [16].”
BackgroundPractical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Clinical Epidemiology: A Basic Science for Clinical Medicine.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-825_9 · Cited by 3,476
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 1×
“For a rDOR 1, the reverse holds [22].”
BackgroundSelf-citationAnderson, D., Rodger, M., Ginsberg, J., Kearon, C., Gent, M., Turpie, A., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., et al. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613830 · Cited by 1,659 · cited 1×
“Logistic regression can be used to construct decision rules, reflecting the combined diagnostic value of a number of diagnostic variables [25].”
MethodMoses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405 · cited 2×
“The approach by Littenberg and Moses relies on the linear regression of the logarithm of the DOR of a study (dependent variable) on a expression of the positivity threshold of that study (independent variable).”
MethodStatistics Notes: The odds ratio
Bland, J. M. (2000) · BMJ · doi:10.1136/bmj.320.7247.1468 · Cited by 1,294
THE ESTIMATION AND SIGNIFICANCE OF THE LOGARITHM OF A RATIO OF FREQUENCIES
HALDANE, B. J. B. S. (1956) · Annals of Human Genetics · doi:10.1111/j.1469-1809.1955.tb01285.x · Cited by 1,076 · cited 1×
“5 to all counts in the table is a commonly used method to calculate an approximation of the DOR [10,11].”
MethodClinical Epidemiology - a basic science for clinical medicine
Hoffbrand, B. I. (1992) · Postgraduate Medical Journal · doi:10.1136/pgmj.68.806.987-a · Cited by 783
Research works printed but not linked: 1
- The Methods Working Group. On systematic review of screening and diagnostic tests: recommended methods. 1995; http://www.cochrane.org.au/.
Cited by
Items 901–1,000 of 1,003
Mickenautsch, S., Fu, B., Gudehithlu, S. K., & Berger, V. W. (2014) · BMC Medical Research Methodology · doi:10.1186/1471-2288-14-114 · Cited by 26
“00), the better the predictive accuracy [20].”
Wu, L., Chen, X.-X., Li, Y.-L., Hua, J., Chen, J., Hu, J., & Xu, J.-R. (2013) · Academic Radiology · doi:10.1016/j.acra.2013.10.008 · Cited by 28
“This measure is a single indicator of test accuracy that comprises a combination of sensitivity and specificity information (18).”
BackgroundZhou, Q., Ye, Z. J., Su, Y., Zhang, J. C., & Shi, H. (2010) · Heart · doi:10.1136/hrt.2009.188474 · Cited by 27
Chen, C., Huang, L., Bai, C., & Lee, C.-C. (2016) · Annals of Saudi Medicine · doi:10.5144/0256-4947.2016.245 · Cited by 34
Insights into permanent pacemaker implantation following TAVR in a real-world cohort
Tichelbäcker, T., Bergau, L., Puls, M., Friede, T., Mütze, T., Maier, L. S., Frey, N., Hasenfuss, G. P., Zabel, M., Jacobshagen, C., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204503 · Cited by 30
The diagnostic value of APT for food allergy in children: a systematic review and meta‐analysis
Luo, Y., Zhang, G., & Li, Z. (2019) · Pediatric Allergy and Immunology · doi:10.1111/pai.13031 · Cited by 27
Qian, S., Zhang, S., Lu, M., Chen, S., Liu, L., Liu, S., Jiang, F., & Zhang, J. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1310383 · Cited by 31
Ciccarone, F., Biscione, A., Robba, E., Pasciuto, T., Giannarelli, D., Gui, B., Manfredi, R. M., Ferrandina, G., Romualdi, D., Moro, F., et al. (2024) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2024.07.027 · Cited by 26
MicroRNAs as ideal biomarkers for the diagnosis of lung cancer
Guo, Z., Zhao, C., & Wang, Z. (2014) · Tumor Biology · doi:10.1007/s13277-014-2330-1 · Cited by 28
Cui, Z., Chen, Y., Xiao, Z., Hu, M., Lin, Y., Chen, Y., & Zheng, Y. (2016) · Oncotarget · doi:10.18632/oncotarget.8268 · Cited by 26
“0 to infinity) is another indicator in mirroring discriminating power of a diagnostic test [27].”
BackgroundDiagnostic Value of Methylated Septin9 for Colorectal Cancer Screening: A Meta-Analysis
Yan, S., Liu, Z., Yu, S., & Bao, Y. (2016) · Medical Science Monitor · doi:10.12659/msm.900590 · Cited by 26
“DOR is a single indicator of test accuracy [32] that combines the data from sensitivity and specificity into a single number.”
BackgroundValuation of University-Originated Technologies: A Predictive Analytics Approach
Kim, Y., Ahn, J. M., Kwon, O.-J., & Lee, C. (2019) · IEEE Transactions on Engineering Management · doi:10.1109/tem.2019.2938182 · Cited by 33
“Second, to compensate for the classes having different weights in our case study and because of possible imbalances in the dataset [30], we add the precision (positive predictive value), recall (true positive rate or sensitivity), and diagnostic odds ratio (DOR) [18].”
BackgroundMultispectral autofluorescence dermoscope for skin lesion assessment
Romano, R. A., Rosa, R. G. T., Sálvio, A. G., Jo, J. A., & Kurachi, C. (2020) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2020.101704 · Cited by 26
Gene Signatures of Early Response to Anti-TNF Drugs in Pediatric Inflammatory Bowel Disease
Salvador‐Martín, S., Raposo-Gutiérrez, I., Navas‐López, V. M., Gallego‐Fernández, C., Moreno‐Álvarez, A., Solar‐Boga, A., Muñoz‐Codoceo, R., Magallares, L., Martínez‐Ojinaga, E., Fobelo, M. J., et al. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21093364 · Cited by 32
“The PPV, NPV, sensitivity, specificity and diagnostic odds ratios for SMAD7 relative expression were calculated as previously described [51].”
MethodSantis, S. D., Cozzolino, R., Luchetti, R., & Cazzoletti, L. (2021) · Journal of Wrist Surgery · doi:10.1055/s-0041-1729757 · Cited by 26
Small Study Effects in Diagnostic Imaging Accuracy: A Meta-Analysis
Lu, L., Phua, Q. S., Bacchi, S., Goh, R., Gupta, A. K., Kovoor, J. G., Ovenden, C. D., & To, M. (2022) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.28776 · Cited by 33
“Of these primary studies, the smallest trial included 5 participants; the largest, 3200 participants; there was a mean (SD) of 122 (186) participants and median (IQR) of 80 (46-137) participants per study.”
Salle, G. D., Tumminello, L., Laino, M. E., Shalaby, S. Y., Aghakhanyan, G., Fanni, S. C., Febi, M., Shortrede, J. E., Miccoli, M., Faggioni, L., et al. (2023) · Radiology Artificial Intelligence · doi:10.1148/ryai.220257 · Cited by 38
“To address the impact of heterogeneity on the meta-analysis (21), we also assessed I 2 and Cochran Q of positive and negative likelihood ratios and the associated diagnostic odds ratios (20).”
MethodNujum, Z. T., Thomas, A., Vijayakumar, K., Nair, R. R., Pillai, M. R., Indu, P. S., Sundar, S., Gopakumar, S., Mohan, D., & Sudheeshkumar, T. K. (2014) · Pathogens and Global Health · doi:10.1179/2047773214y.0000000131 · Cited by 26
Goarant, C., Bourhy, P., D’Ortenzio, É., Dartevelle, S., Mauron, C., Soupé-Gilbert, M.-E., Bruyère-Ostells, L., Gourinat, A.-C., Picardeau, M., Nato, F., et al. (2013) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0002289 · Cited by 28
“These characteristics make the DOR particularly useful for comparing tests whenever the balance between false negative and false positive rates is not of immediate importance [20].”
Xu, G., Li, C. Y., Zhao, L., & He, Z. (2012) · Annals of Oncology · doi:10.1093/annonc/mds234 · Cited by 26
“The DOR is a single indicator of test accuracy that combines the data from sensitivity and specificity into a single number [30].”
BackgroundXu, L., Guo, Y., Zhang, X., Chen, J., & Hu, S. (2016) · Cellular Physiology and Biochemistry · doi:10.1159/000443046 · Cited by 28
Dankerl, P., Seuß, H., Ellmann, S., Cavallaro, A., Uder, M., & Hammon, M. (2016) · Academic Radiology · doi:10.1016/j.acra.2016.09.022 · Cited by 26
Dinets, A., Pernemalm, M., Kjellin, H., Sviatoha, V., Sofiadis, A., Juhlin, C. C., Zedenius, J., Larsson, C., Lehtiö, J., & Höög, A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0126472 · Cited by 26
Diagnostic performance of C-reactive protein for parapneumonic pleural effusion: a meta-analysis
Li, D., Shen, Y., Qin, J., Wan, C., Zeng, N., Chen, L., & Dong, Y. (2019) · Annals of Translational Medicine · doi:10.21037/atm.2018.11.44 · Cited by 27
“The DOR, a single indicator of test performance in diagnostic meta-analysis (34), was 18.”
BackgroundPenn, A. M. W., Bibok, M. B., Saly, V. K., Coutts, S. B., Lesperance, M., Balshaw, R. F., Votova, K., Croteau, N. S., Trivedi, A., Jackson, A., et al. (2018) · Biomarkers · doi:10.1080/1354750x.2018.1499130 · Cited by 27
“For all models, the diagnostic odds ratio (DOR) (Moses et al. 1993, Glas et al. 2003), area under the receiver operating characteristic curve (AUC), sensitivity (Sen), specificity (Spe) and diagnostic accuracy (ACC) were determined, and 95% confidence intervals were computed.”
MethodBeyond Volume: The Impact of Complex Healthcare Data on the Machine Learning Pipeline
Feldman, K., Faust, L. J., Wu, X., Huang, C., & Chawla, N. V. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-69775-8_9 · Cited by 28
“performance range quantified by metrics such as sensitivity and specificity, predictive values, chance-corrected measures of agreement, or likelihood ratios [58].”
BackgroundJiang, Y., Hu, Z., Zuo, Z., Li, Y., Pu, F., Wang, B., Tang, Y., Guo, Y., & Tao, H. (2020) · BioMed Research International · doi:10.1155/2020/4947381 · Cited by 28
“And the higher of DOR value is, the better of diagnostic efficacy will be [64].”
BackgroundPhiri, D., Makowa, F., Amelia, V. L., Phiri, Y. V. A., Dlamini, L. P., & Chung, M. (2025) · Journal of Medical Internet Research · doi:10.2196/59002 · Cited by 58
“Furthermore, for studies that provided sufficient information to compute sensitivity and specificity, we used this information to calculate odds ratios [36], which were then converted into r values by using Comprehensive Meta-Analysis (version 3; Biostat, Inc).”
Klora, M., Zeidler, J., Linder, R., Verheyen, F., & von der Schulenburg, J.-M. G. (2015) · Health Economics Review · doi:10.1186/s13561-015-0078-y · Cited by 34
“The odds ratio is a proven measure to verify a higher or lower chance for comorbidities in the intervention group [18, 19].”
BackgroundZhou, Y., Wang, C., Zhu, H., Lin, Y., Pan, B., Zhang, X., Huang, X., Xu, Q., Xu, Y., & Sun, Q. (2016) · PLoS ONE · doi:10.1371/journal.pone.0158143 · Cited by 26
“which is a single indicator measure of the overall diagnostic test accuracy [21].”
BackgroundZhou, W., Tao, J., Li, J., & Tao, S. (2020) · Medicine · doi:10.1097/md.0000000000020937 · Cited by 30
“The numbers of false-, true-positives or false-, true-negatives in patients with CRC and HC were used to calculate sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR)([16]) and 95% confidence interval (CI).”
MethodInfluentialFoko, L. P. K., Pande, V., & Singh, V. (2021) · Diagnostics · doi:10.3390/diagnostics11040590 · Cited by 27
“The larger the DOR value, the more accurate the test is [22].”
BackgroundEvaluation of the diagnostic accuracy of bronchial brushing cytology in lung cancer: A meta‐analysis
Chen, C., Bai, C., Lee, K., Chou, Y., Pan, S., & Wang, Y. (2021) · Cancer Cytopathology · doi:10.1002/cncy.22436 · Cited by 30
Staibano, P., Forner, D. W. A., Noel, C. W., Zhang, H., Gupta, M. K., Monteiro, E., Sawka, A. M., Pasternak, J. D., Goldstein, D. P., & de Almeida, J. R. (2021) · The Laryngoscope · doi:10.1002/lary.29778 · Cited by 33
“The DOR is a measure of the effectiveness of a diagnostic test which takes into account the ratio of true and false results with higher values indicating better diagnostic performance.(32) Furthermore, a positive LR represents the likelihood that a positive test result (i.”
BackgroundBenedetti, D., Olcese, U., Bruno, S., Barsotti, M., Maestri, M., Bonanni, E., Siciliano, G., & Faraguna, U. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s352335 · Cited by 24
“Even if useful for comparing diagnostic tests, DOR only is not sufficient to decide whether to include a new diagnostic tool in the clinical practice.(47) For this purpose, PPV and NPVare more reliable parameters.”
MethodAnalysis of circulating microRNA biomarkers for breast cancer detection: a meta-analysis
Liu, L., Wang, S., Cao, X., & Liu, J. (2014) · Tumor Biology · doi:10.1007/s13277-014-2533-5 · Cited by 26
“The value of a DOR is also recommended for evaluating the accuracy of a diagnostic test; it ranges from 0 to infinity, with higher values indicating better performance [38].”
BackgroundXu, Y.-B., Min, Z.-G., Jiang, H.-X., Qin, S.-Y., & Hu, B.-L. (2013) · Transplantation Proceedings · doi:10.1016/j.transproceed.2013.03.031 · Cited by 25
Predictive power of circulating miRNAs in detecting colorectal cancer
Zeng, W., Tu, Y., Zhu, Y., Wang, Z., Li, C., Lao, L., & Wu, G. (2014) · Tumor Biology · doi:10.1007/s13277-014-2872-2 · Cited by 30
Yamamoto, N., Satomi, J., Tada, Y., Harada, M., Izumi, Y., Nagahiro, S., & Kaji, R. (2014) · Stroke · doi:10.1161/strokeaha.114.007227 · Cited by 25
Conjeti, S., Katouzian, A., Roy, A. G., Peter, L., Sheet, D., CARLIER, S. G., Laine, A. F., & Navab, N. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.02.005 · Cited by 29
MiR-16 family as potential diagnostic biomarkers for cancer: a systematic review and meta-analysis.
Cui, J. (2015) · PubMed · Cited by 25
Ahmad, M., Sharif, K., Qayyum, H., Ehsanullah, B., Balyasnikova, S., Wale, A., Shanmuganandan, A., Siddiqui, M. R. S., Athanasiou, T., & Kemp, G. J. (2017) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2017-134945 · Cited by 30
“Verification bias occurs when one test determines the choice of subsequent tests [30].”
BackgroundPerformance of procalcitonin in diagnosing parapneumonic pleural effusions
He, C. S., Wang, B., Li, D., Xu, H., & Shen, Y. (2017) · Medicine · doi:10.1097/md.0000000000007829 · Cited by 25
“DOR combines the sensitivity and specificity data into a single number ranging from 0 to infinity, with higher values indicating better discriminatory test performance.([29]) The mean pooled DOR in our meta-analysis was 12.”
BackgroundSchröder, Â. G. D., de Araújo, C. M., Filho, O. G., Flores‐Mir, C., Canto, G. D. L., & Porporatti, A. L. (2019) · Clinical Oral Investigations · doi:10.1007/s00784-019-02880-6 · Cited by 25
Automated False Alarm Reduction in a Real-Life Intensive Care Setting Using Motion Detection
Muroi, C., Meier, S., De Luca, V., Mack, D. J., Strässle, C., Schwab, P., Karlen, W., & Keller, E. (2020) · Neurocritical Care · doi:10.1007/s12028-019-00711-w · Cited by 22
Kim, S.-J., & Lee, S. W. (2019) · Clinical Radiology · doi:10.1016/j.crad.2019.06.022 · Cited by 26
Xiao, Y., Zhang, J., He, X., Ji, J., & Wang, G. (2013) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-013-1051-6 · Cited by 25
“In addition, as an indicator of test accuracy that combines data from sensitivity and specificity into a single number [45], DOR was applied to indicate better discriminatory test performance.”
MethodMoorthy, M., Daniel, H., Kurian, G., & Abraham, P. (2008) · Indian Journal of Medical Microbiology · doi:10.4103/0255-0857.42116 · Cited by 25
Wu, Q., Li, M., ZHANG, S., Chen, L., Gu, X., & Xu, F. (2014) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2014.2039 · Cited by 24
“The higher the DOR value, the more discriminatory the test (47).”
BackgroundAbdelmoneim, S. S., Bernier, M., Dhoble, A., Moir, S., Hagen, M. E., Ness, S. A. C., Abdel‐Kader, S. S., Pellikka, P. A., & Mulvagh, S. L. (2010) · Echocardiography · doi:10.1111/j.1540-8175.2009.01026.x · Cited by 24
A Meta-Analysis of the Diagnostic Accuracy of Circular RNAs in Digestive System Malignancy
Chen, Z., Zhang, L., Han, G., Zuo, X., Zhang, Y., Zhu, Q., Wu, J., & Wang, X. (2018) · Cellular Physiology and Biochemistry · doi:10.1159/000487291 · Cited by 24
Determining gestational age and preterm birth in rural Guatemala: A comparison of methods
Weinstein, J. R., Thompson, L. M., Díaz-Artiga, A., Bryan, J. P., Arriaga, W. E., Omer, S. B., & McCracken, J. P. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193666 · Cited by 27
“Using ultrasound as the gold-standard method, the sensitivities, specificities, and diagnostic odds ratios [34] for each method were determined.”
MethodDiagnostic significance of circulating miRNAs in systemic lupus erythematosus
Zheng, X., Zhang, Y., Yue, P., Liu, L., Wang, C., Zhou, K., Hua, Y., Wu, G., & Li, Y. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217523 · Cited by 24
“The higher the DOR, the better the discriminatory ability of the test was [26].”
BackgroundKim, D. H., Lee, S., & Hwang, S. H. (2019) · Otology & Neurotology · doi:10.1097/mao.0000000000002416 · Cited by 24
He, Y., Wang, Y., Li, Z., Chen, H., Deng, J., Huang, H., He, X., Zeng, W., Liu, M., Huang, B., et al. (2020) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13842 · Cited by 28
Buś, S., Jędrzejewski, K., & Guzik, P. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11144004 · Cited by 25
“accuracy, sensitivity, specificity, positive predictive value (PPV), and diagnostic odds ratio (DOR) [66] of the classification.”
BackgroundMethodInfluentialDiagnostic significance of microRNAs in sepsis
Zheng, X., Zhang, Y., Lin, S., Li, Y., Hua, Y., & Zhou, K. (2023) · PLoS ONE · doi:10.1371/journal.pone.0279726 · Cited by 24
“DOR indicated that patients with positive results are much more likely to have sepsis than patients with negative results, and a higher DOR showed that the test had stronger discriminatory ability [27].”
BackgroundZhang, Z., Yang, J., Zhang, C., Li, K., Quan, Q., Wang, X., Wang, H., & Zhang, G. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.01.004 · Cited by 28
Balasubramanian, C. K., Boyette, A., & Wludyka, P. S. (2015) · Physiotherapy Canada · doi:10.3138/ptc.2014-19 · Cited by 24
Shi, J., Li, J., Hu, R., Li, C., Wen, Y., Zheng, H., Zhang, F., & Li, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0065436 · Cited by 25
“The DOR represents a single indicator of test accuracy [30].”
BackgroundMouton, A., Jowett, I. G., Goethals, P. L. M., & Baets, B. D. (2009) · Ecological Informatics · doi:10.1016/j.ecoinf.2009.07.006 · Cited by 26
Taneja, N., Nato, F., Dartevelle, S., Sire, J.-M., Garin, B., Phuong, L. N. T., Diep, T. T., Shako, J.-C., Bimet, F., Filliol, I., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024830 · Cited by 24
“The diagnostic odds ratio (DOR), defined as the ratio of the odds of positive test results in specimens with the target disorder relative to the odds of positive test results in specimens without the target disorder, was calculated as follows [46]: DOR = (Se/[1 - Se])/([1 Sp]/Sp).”
MethodRoman-Rodriguez, C. F., Weissbrot, E. S., Hsu, C., Wong, A., Siefert, C. J., & Sung, L. (2015) · Taiwanese Journal of Obstetrics and Gynecology · doi:10.1016/j.tjog.2015.02.004 · Cited by 26
“necessarily problematic, especially when OR is strong [19].”
BackgroundDiagnostic Accuracy of Seven Commercial Assays for Rapid Detection of Group A Rotavirus Antigens
Kaplon, J., Fremy, C., Pillet, S., Martins, L. M., Ambert‐Balay, K., Aho, S., & Pothier, P. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.01984-15 · Cited by 24
“These data indicated a strong association between the results of the rotavirus ICT assays and the presence of the virus; these assays were therefore highly discriminatory (7, 8).”
ResultRichter, V., Carlmeyer, B., Lier, F., zu Borgsen, S. M., Schlangen, D., Kümmert, F., Wachsmuth, S., & Wrede, B. (2016) · International Conference on Human-Agent Interaction (HAI) · doi:10.1145/2974804.2974823 · Cited by 32
Schweitzer, C., Korobelnik, J., Goff, M. L., Rahimian, O., Malet, F., Rougier, M., Delyfer, M., Dartigues, J., & Delcourt, C. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-20104 · Cited by 26
Shen, Y., Li, Y., Zheng, H.-T., Tang, B., & Yang, M. (2019) · BMC Bioinformatics · doi:10.1186/s12859-019-2924-0 · Cited by 33
“…that is based on the co-occurrence frequency, which was presented in [38] (SDNB ontology + improved NB); and (d) with a symptom-dependency-aware weighted naïve Bayes classifier that is realized via odds ratio (OR) value [39] evaluation and AdaBoost optimization (SDNB ontology+ SDNB classifier).”
MethodDiagnostic performance of CT angiography to detect pulmonary vein stenosis in children
Barrera, C. A., Saul, D., Rapp, J. B., Smith, C. L., White, A. M., Biko, D. M., & Otero, H. J. (2019) · International journal of cardiac imaging · doi:10.1007/s10554-019-01693-8 · Cited by 24
Hu, X., Xing, B., Wang, W., Yang, P.-W., Sun, Y., Zheng, X., Shang, Y., Chen, F., Liu, N., Yang, L., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-73220-y · Cited by 31
Whole Transcription Profile of Responders to Anti-TNF Drugs in Pediatric Inflammatory Bowel Disease
Salvador‐Martín, S., Kaczmarczyk, B., Álvarez, R., Navas‐López, V. M., Gallego‐Fernández, C., Moreno‐Álvarez, A., Solar‐Boga, A., Sánchez, C., Tolin, M., Rodríguez‐Belvís, M. V., et al. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13010077 · Cited by 24
“The positive predictive value (PPV), negative predictive value (NPV), sensitivity, specificity, and diagnostic odds ratios for relative expression of GBP1, FCGR1A, and FCGR1B were calculated as described elsewhere [20].”
MethodUltrasonography for confirmation of gastric tube placement
Tsujimoto, H., Tsujimoto, Y., Nakata, Y., Akazawa, M., & Kataoka, Y. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012083 · Cited by 24
Wu, D., & Qin, H. (2023) · The Journal of Infection in Developing Countries · doi:10.3855/jidc.17907 · Cited by 28
“In this study, this combination exhibited the best diagnostic performance for sepsis among all indicators (sensitivity 67.4%, specificity 65.8%), especially in the non-survival group ( p 0.001), which agrees with the findings in previous studies [19-20].”
ResultInfluentialIntraoperative Parathyroid Hormone Monitoring Criteria in Primary Hyperparathyroidism
Staibano, P., Au, M., Zhang, H., Yu, S., Liu, W., Pasternak, J. D., Xing, X., Seib, C. D., Orloff, L. A., Nguyen, N.-T., et al. (2024) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2024.4453 · Cited by 23
Heng, B., Li, Y., Shi, L., Du, X., Lai, C., Cheng, L., & Su, Z. (2015) · Transplantation · doi:10.1097/tp.0000000000000567 · Cited by 25
“The DOR of a test is the ratio of the odds of positivity in disease relative to the odds of positivity in the nondiseased with higher values indicating better discriminatory test performance.(13) The LRs indicate how much a given test would raise or lower the probability of having disease.”
BackgroundWu, G., Yue, P., Ma, F., Zhang, Y., Zheng, X., & Li, Y. (2020) · Medicine · doi:10.1097/md.0000000000018535 · Cited by 23
“The higher the DOR, the better the discriminatory ability of the test was.([24]) The SROC was plotted by the combination of sensitivity and specificity, and the area under the curve (AUC) value was then calculated as a global measurement of test performance.”
MethodAlkhatip, A. A. A. M. M., Donnelly, M. B., Snyman, L., Conroy, P. H., Hamza, M., Murphy, I., Purcell, A., & McGuire, D. (2020) · Critical Care Medicine · doi:10.1097/ccm.0000000000004271 · Cited by 23
Diagnostic value of ultrasound-guided needle biopsy in undiagnosed pleural effusions
Lin, Z., Wu, D., Wang, J., Wang, C., & Huang, M. (2020) · Medicine · doi:10.1097/md.0000000000021076 · Cited by 25
Zhang, Y., Li, X., Liu, J., Hu, X., Wan, C., Zhang, R., & Shen, Y. (2021) · Annals of Medicine · doi:10.1080/07853890.2021.1906943 · Cited by 23
“The DOR value combines sensitivity and specificity data into a single number ranging from 0 to infinity; higher DOR values indicate better discriminatory test performance [27].”
BackgroundDautzenberg, G., Lijmer, J. G., & Beekman, A. T. F. (2021) · International Psychogeriatrics · doi:10.1017/s1041610221000612 · Cited by 28
“However, with these indicators, it is impossible to weigh the FN and FP rates separately, which is a disadvantage, and absolute quantities can provide more insight when diagnostic routes are compared (Glas et al., 2003).”
BackgroundSelf-citationQiu, L., & Weng, G. (2022) · Journal of Ovarian Research · doi:10.1186/s13048-022-00985-3 · Cited by 24
“The value of DOR ranges from 0 to infinity, where a higher value means better cancer diagnosis [50].”
BackgroundCirculating MicroRNAs as Potential Diagnostic Biomarkers for Diabetic Retinopathy: A Meta-Analysis
Ma, L., Wen, Y., Li, Z., Wu, N., & Wang, Q. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.929924 · Cited by 26
“DOR is an indicator of discriminatory test performance (47), and a DOR value greater than 1 indicates a better diagnostic test, with a DOR of 23, representing the ability of the miRNA to effectively discriminate between DR patients and non-DR control populations.”
BackgroundDiGennaro, C., Vahdat, V., Jalali, M. S., Toumi, A., Watson, T. R., Gazelle, G. S., Mercaldo, N. D., & Lubitz, C. C. (2022) · Thyroid · doi:10.1089/thy.2022.0269 · Cited by 23
“29 Cochran’s Q test 30 was used to assess underlying population heterogeneity between studies evaluating the same molecular test.”
Trinidad, M. I., Hong, X., Froelich, S., Daiker, J., Sacco, J., Nguyen, H. P., Campagna, M., Suhr, D., Suhr, T. R., LeBowitz, J. H., et al. (2023) · Genome biology · doi:10.1186/s13059-023-03001-z · Cited by 32
“We calculated the diagnostic odds ratio (DOR) of our enzymatic assay using the CDS activity and patient-based severity classifications for variants that occurred 5 or more times in patients or were known to be benign [16].”
MethodPaolini, F., Campo, F., Iocca, O., Manciocco, V., VIRGILIO, A. D., Pascale, V. D., Moretto, S., Dalfino, G., Vidiri, A., Blandino, G., et al. (2023) · Head & Neck · doi:10.1002/hed.27515 · Cited by 23
Liu, Y., Qin, S.-B., Lan, C., Huang, Q., Zhang, P., & Cao, W. (2024) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2024.106996 · Cited by 26
Duo, J., Han, X., Zhang, L., Wang, G., Ma, Y., & Yang, Y. (2013) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e3182817af3 · Cited by 23
“It is the ratio of the odds of a positive test in a patient with disease relative to the odds of positive test in a patient without disease and has a value that ranges from 0 to infinity, with higher values indicating better discriminatory test performance.(32) This meta-analysis showed that the DOR values for PET/CT…”
BackgroundChen, L., & Jin, H. D. (2014) · Tumor Biology · doi:10.1007/s13277-014-2188-2 · Cited by 23
“The DOR, ranging from 0 to infinity, is a measure of test performance combining the strengths of sensitivity and specificity [29].”
BackgroundKraemer, R., Smith, H., Sigrist, T., Giger, G., Keller, R., & Frey, M. (2016) · Respiratory Research · doi:10.1186/s12931-016-0470-0 · Cited by 26
“(DOCX 128 kb) Abbreviations AHR: Airway hyperreactivity; APS: Aerosol provocation system; ATS: American thoracic society; AUC: Area und the curve; BL: Baseline; CD: Cumulative dose; DOR: Diagnostic odds ratio; EELV: End-expiratory lung volume; ERS: European respiratory society; FEF25–75: Forced expiratory flow between…”
BackgroundTomás, I., Regueira‐Iglesias, A., López, M. C., Arias‐Bujanda, N., Nóvoa, L., Balsa‐Castro, C., & Tomás, M. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2017.01443 · Cited by 27
Zeng, N., Wan, C., Qin, J., Wu, Y., Yang, T., Shen, Y., Wen, F., & Chen, L. (2017) · BMC Pulmonary Medicine · doi:10.1186/s12890-017-0530-3 · Cited by 23
“[65] Higher DOR indicates better discriminatory test performance.”
BackgroundDiagnostic validity of methods for assessment of swallowing sounds: a systematic review
Taveira, K. V. M., Santos, R. S., Cavalcante-Leão, B. L., Stechman‐Neto, J., Pernambuco, L. D. A., da Silva, L. K., Canto, G. D. L., & Porporatti, A. L. (2018) · Brazilian Journal of Otorhinolaryngology · doi:10.1016/j.bjorl.2017.12.008 · Cited by 29
Kim, S., Pak, K., & Kim, K. (2019) · Abdominal Radiology · doi:10.1007/s00261-018-01891-3 · Cited by 27
Yu, W., Kou, C., Bai, W., Yu, X., Duan, R., Zhu, B., Li, Y., Hua, W., Ren, X., & Yang, Y.-M. (2019) · PLoS ONE · doi:10.1371/journal.pone.0220080 · Cited by 24
Zhou, X., Fang, S., Wang, M., Xiong, A., Zheng, C., Wang, J., & Yin, C. (2019) · Bioscience Reports · doi:10.1042/bsr20190900 · Cited by 23
Association Between Low Blood Pressure and Clinical Outcomes in Patients With Acute Ischemic Stroke
Verschoof, M. A., Groot, A. E. D., Vermeij, J., Westendorp, W. F., van den Berg, S. A., Nederkoorn, P. J., van de Beek, D., & Coutinho, J. M. (2019) · Stroke · doi:10.1161/strokeaha.119.027336 · Cited by 23
“5 to all 4 cells of the 2×2 table for the unadjusted analyses.(6)”
BackgroundEvaluation of Diagnostic Tests
Fardy, J. (2008) · Methods in molecular biology · doi:10.1007/978-1-59745-385-1_7 · Cited by 25
“There is also a close relationship between the DOR and the likelihood ratios (5) :”
BackgroundInfluentialChan, C.-K., Yip, S. K., Wu, I. P. H., Li, M., & Chan, N. H. (2011) · British Journal of Urology · doi:10.1111/j.1464-410x.2011.10581.x · Cited by 23
Eloubeidi, M. A., Luz, L. P., Tamhane, A. R., Khan, M., & Buxbaum, J. L. (2012) · Pancreas · doi:10.1097/mpa.0b013e31827305b8 · Cited by 23
“It ranges from zero to infinity with higher values indicating better discriminating test performance.(16) After selecting the optimal PDG ratio, multivariable analysis was conducted to examine the significance of the PDG ratio in predicting PC, adjusting for the clinically significant confounders namely age, sex, and…”
MethodHill, S., Balion, C. M., Santaguida, P. L., McQueen, M., Ismaila, A., Reichert, S. M., McKelvie, R. S., Worster, A., & Raina, P. S. (2007) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2007.08.016 · Cited by 25
“90 [5], and to a LR− of 0.”
Cook, R. B., Collins, D., Tucker, J., & Zioupos, P. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.02.003 · Cited by 28
Metadata
- Authors
- Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M.
- Affiliations
- Amsterdam UMC Location University of Amsterdam (NL)
- University Medical Center Utrecht (NL)
- Maastricht University (NL)
- Corresponding author
- Glas, Afina S.
- Venue
- Journal of Clinical Epidemiology
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 56
- Issue
- 11
- Pages
- 1129-1135
- ISSN
- 0895-4356 (ISSN-L)
- OpenAlex
- W2092926517
- Semantic Scholar
- 044658ead3fe5730abbc7cde18fdc2bbe09d3abf
- Cited by
- 2,261
- References
- 30
- Citations by year
- 2026: 72 · 2025: 109 · 2024: 149 · 2023: 129 · 2022: 120 · 2021: 162 · 2020: 166 · 2019: 137 · 2018: 146 · 2017: 158 · 2016: 124 · 2015: 135 · 2014: 140 · 2013: 122 · 2012: 97
- FWCI
- 15.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Clinical Epidemiology (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- diagnostic odds ratio, diagnostic performance, sensitivity and specificity, meta-analysis of diagnostic studies, logistic model, inhomogeneity correction, test comparison
- MeSH terms
- Diagnosis, Humans, Predictive Value of Tests, Sensitivity and Specificity, Meta-Analysis as Topic, Logistic Models, Odds Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.