The DOI matches its Crossref record.
Is resistant hypertension really resistant?
Open accessAbstract
BACKGROUND: Managing resistant hypertension is difficult and mostly involves expensive testing seeking an underlying secondary cause. This study was undertaken to determine 1) the extent of the white-coat phenomenon in patients with resistant hypertension, and 2) whether 24-h ambulatory blood pressure (BP) monitoring (ABPM) or having BP recorded by a nurse instead of the referring doctor could clarify how many apparently resistant hypertensives actually have controlled BP. METHODS: This study involved 611 patients with BP > or = 140/90 mm Hg who were referred for 24-h ABPM by their specialist or general practitioner, including 277 patients who were taking no antihypertensives (group 1), 216 taking one or two antihypertensive drugs (group 2), and 118 taking at least three antihypertensives in combination (group 3). Each had BP recorded by one of two nurses before 24-h ABPM. Controlled BP was defined as awake ambulatory BP <135/85 mm Hg and the white-coat effect was the difference between the BP recorded by the referring doctor or nurse and the average awake ambulatory BP. RESULTS: Those with resistant hypertension (group 3) were older (61 years (12) v group 1: 46 years (14) and group 2: 56 (14) years; P < .001), but were of similar weight, height, and arm circumference to the other groups. Referral systolic, but not diastolic BP was higher in resistant hypertensives (mean 171/95 v 154/95 mm Hg and 164/94 mm Hg, respectively, P < .001 for systolic BP only). Twenty-eight percent of resistant hypertensives and 32% of those taking no antihypertensive drugs had normal awake ambulatory BP and the white-coat effect attributable to the referring doctor was always greater than that due to the nurse (range 16 to 26/12 to 14 mm Hg v 9 to 17/4 mm Hg, P < .001). Nurse recorded BP was highly sensitive (97%) in identifying awake hypertension but lacked specificity (57%) to replace ABPM. CONCLUSION: Our results show that approximately one in four patients with apparent resistant hypertension referred for ABPM have controlled BP and one-third of patients referred for initial evaluation of office or clinic hypertension have normal BP using ABPM, ie, white-coat hypertension. Twenty-four-hour ABPM appears an appropriate initial step before further investigating or treating patients with apparently resistant hypertension.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calhoun, D. A., Jones, D., Textor, S., Goff, D. C., Murphy, T. P., Toto, R. D., White, A., Cushman, W. C., White, W., Sica, D., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189141 · Cited by 2,237
Brown, M. A., Magee, L. A., Kenny, L. C., Karumanchi, S. A., McCarthy, F. P., Saito, S., Hall, D. R., Warren, C. E., Adoyi, G., & Ishaku, S. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10803 · Cited by 2,089
“This diagnosis can be avoided in large part by having clinic or office BP recorded by a nurse, rather than a doctor, preferably using repeated BP readings.(25) We recommend that all women have either home BP monitoring monitoring or 24-hour ABPM before a diagnosis of true essential hypertension is accepted.”
MethodSelf-citationMeasurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“Studies have shown that a high percentage (30%–40%) of patients taking multiple classes of antihypertensive medication with SBP ≥140 mm Hg or DBP ≥90 mm Hg based on measurements taken in the clinic have the white-coat effect.(104,105) Because white-coat hypertension and the white-coat effect in many cases are attribut…”
BackgroundTranquilli, A. L., Dekker, G., Magee, L., Roberts, J., Sibai, B. M., Steyn, W., Zeeman, G. G., & Brown, M. A. (2014) · Pregnancy Hypertension: An International Journal of Women's Cardiovascular Health · doi:10.1016/j.preghy.2014.02.001 · Cited by 1,417
Self-citationCalhoun, D. A., Jones, D., Textor, S., Goff, D. C., Murphy, T. P., Toto, R. D., White, A., Cushman, W. C., White, W., Sica, D., et al. (2008) · Hypertension · doi:10.1161/hypertensionaha.108.189141 · Cited by 1,413
Metadata
- Authors
- Brown, M.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-12
- Volume
- 14
- Issue
- 12
- Pages
- 1263-1269
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2076609670
- Cited by
- 193
- References
- 0
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is resistant hypertension really resistant? https://app.cochat.ai/papers/10.1016/s0895-7061(01)02193-8
- The paper
- Brown, M. (2001). Is resistant hypertension really resistant? American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(01)02193-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.