Associations between nondipping of nocturnal blood pressure decrease and cardiovascular target organ damage in strictly selected community-dwelling normotensives
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: In hypertensives, nondippers are more likely than dippers to suffer silent, as well as overt, hypertensive target organ damage. In this study, we investigated whether a nondipper status was associated with target organ damage in normotensives. METHODS: We performed ambulatory blood pressure (BP) monitoring, echocardiography, and carotid ultrasonography and measured natriuretic peptides and urinary albumin (UAE) in 74 normotensive subjects with the following criteria: 1) clinical BP <140/90 mm Hg; 2) average 24-h ambulatory BP <125/80 mm Hg. RESULTS: The left ventricular mass index (LVMI) and the relative wall thickness (RWT) measured by echocardiography were greater in nondippers than dippers (LVMI: 103 +/- 26 v 118 +/- 34 g/m(2), P <.05; RWT: 0.38 +/- 0.07 v 0.43 +/- 0.09, P <.01). Plasma atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) were higher in nondippers than dippers (ANP: 14 +/- 10 v 36 +/- 63 pg/mL, P <.01; BNP: 16 +/- 12 v 62 +/- 153 pg/mL, P <.05). There were no significant differences in UAE and intima-media thickness measured by carotid ultrasonography. CONCLUSIONS: Normotensive nondipping may not reflect renal damage, but may have a predominant effect on cardiac damage. Nondipping of nocturnal BP seems to be a determinant of cardiac hypertrophy and remodeling, and may result in a cardiovascular risk independent of ambulatory BP levels in normotensives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levy, D., Garrison, R. J., Savage, D. D., Kannel, W. B., & Castelli, W. P. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005313222203 · Cited by 5,699
Koren, M. J., Devereux, R. B., Casale, P. N., Savage, D. D., & Laragh, J. H. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-5-345 · Cited by 2,366
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationTwenty-four-hour ambulatory blood pressure in children with sleep-disordered breathing
Amin, R. S., Carroll, J. L., Jeffries, J. L., Grone, C., Bean, J. A., Chini, B., Bokulic, R., & Daniels, S. R. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200309-1305oc · Cited by 354
Nocturnal Hypertension: New Technology and Evidence
Kario, K. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.10971 · Cited by 298
Hermida, R. C., Ayala, D. E., Mojón, A., & Fernández, J. R. (2013) · Chronobiology International · doi:10.3109/07420528.2012.701127 · Cited by 203
Lanfranchi, P. A., Pennestri, M.-H., Fradette, L., Dumont, M., Morin, C. M., & Montplaisir, J. (2009) · Sleep · doi:10.1093/sleep/32.6.760 · Cited by 198
Metadata
- Authors
- Hoshide, S.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-06
- Volume
- 16
- Issue
- 6
- Pages
- 434-438
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2028385618
- Cited by
- 239
- References
- 2
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.