CoChat

Home Self-Monitoring of Blood Pressure Is Fully Automated Oscillometric Technique as Good as Conventional Stethoscopic Technique?

Stergiou, G · 1997 · American Journal of Hypertension
Cited by 57

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Home blood pressure (HBP) measurement is becoming increasingly popular as an additional source of information for the practicing physician. Whether HBP measured with a fully automated oscillometric device (oHBP) is more reliable than HBP measured with an aneroid sphygmomanometer and a stethoscope (sHBP) remains unclear. We compared sHBP with oHBP using as a reference method daytime ambulatory blood pressure (ABP), as this is believed to be a better index of an individual's overall level of pressure. Forty-six hypertensive patients measuring HBP with aneroid devices were retrained by a standard 30 min protocol that included training in the technique of measurement, checking patients' devices, and testing patients' performance in stethoscopic measurement. Patients were randomized to measure for 2 weeks either sHBP using their own calibrated aneroid devices or oHBP using a validated fully automated oscillometric device (Omron HEM-705CP). Then 24 h ABP monitoring was performed (SpaceLabs 90207) and patients crossed over for a second 2 week period by using the alternative HBP measurement technique. Mean sHBP was not different from mean oHBP, and there was a close correlation between them (r = 0.82/0.76 for systolic/diastolic BP, P < .001). Daytime ABP was not different from oHBP or sHBP and was closely related to both of them (oHBP, r = 0.59/0.72 systolic/diastolic BP, P < .001; sHBP, 0.50/0.65, P < .001). Age was significantly related with diastolic ABP-sHBP difference (r = 0.33, P < .05). These results suggest that HBP measured with validated fully automated oscillometric devices is equally reliable in predicting average ABP as that measured with calibrated aneroid sphygmomanometers used by very carefully trained patients. In clinical practice, HBP monitoring by using reliable automated devices is probably more feasible than to achieve a high standard of stethoscopic HBP measuring technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0895-7061(96)00402-5

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 57

Metadata

Authors
Stergiou, G.
Venue
American Journal of Hypertension
Published
1997-04
Volume
10
Issue
4
Pages
428-433
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2044029245
Cited by
57
References
1
FWCI
3.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Home Self-Monitoring of Blood Pressure Is Fully Automated Oscillometric Technique as Good as Conventional Stethoscopic Technique? https://app.cochat.ai/papers/10.1016/s0895-7061(96)00402-5
The paper
Stergiou, G. (1997). Home Self-Monitoring of Blood Pressure Is Fully Automated Oscillometric Technique as Good as Conventional Stethoscopic Technique? American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(96)00402-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.