CoChat

Reproducibility of Home Blood Pressure Measurements Over a 1-Year Period

Sakuma, M · 1997 · American Journal of Hypertension
Cited by 121

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We compared the reproducibility over time of blood pressure measured at the health examinations (screening blood pressure) and blood pressure measured at home (home blood pressure). Both screening and home blood pressure were measured in subjects of a rural community. Subjects measured their own blood pressure at home once in the morning using a semiautomatic oscillometric blood pressure measuring device at least three times (on at least 3 days) in each of two 4-week periods separated by one year. Similarly, two screening blood pressure measurements were obtained from the subjects at each of two health examinations also taken 1 year apart. A total of 136 untreated subjects without cardiovascular complications (40 men and 96 women, 56 +/- 11.7 years, mean +/- SD) were analyzed in the study. The correlations between the first and second blood pressure measurements of the subjects were significantly higher for the home blood pressure measurements (systolic: r = 0.844 and diastolic: r = 0.830) than for the screening blood pressure measurements (systolic: r = 0.692 and diastolic: r = 0.570). The mean differences between the first and second home blood pressure (0.8 +/- 7.7 mm Hg for systolic BP and 0.9 +/- 5.5 mm Hg for diastolic BP) were significantly smaller than those for the screening blood pressure (-3.9 +/- 13.8 for systolic BP and -3.1 +/- 10.2 for diastolic BP) (P < .001 for both comparisons), suggesting that the reproducibility of home blood pressure over time is superior to that of screening blood pressure. Such reliable blood pressure measurements obtained at home have a clinical significance for the diagnosis and treatment of hypertension and as a tool for evaluating the efficacy of antihypertensive drugs. Home blood pressure measurements also may be more useful than screening blood pressure measurements in predicting future cardiovascular events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0895-7061(97)00117-9

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 121

Metadata

Authors
Sakuma, M.
Venue
American Journal of Hypertension
Published
1997-07
Volume
10
Issue
7
Pages
798-803
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2071462989
Cited by
121
References
2
FWCI
2.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of Home Blood Pressure Measurements Over a 1-Year Period. https://app.cochat.ai/papers/10.1016/s0895-7061(97)00117-9
The paper
Sakuma, M. (1997). Reproducibility of Home Blood Pressure Measurements Over a 1-Year Period. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(97)00117-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.