White Coat Effect Detected Using Self-Monitoring of Blood Pressure at Home: Comparison With Ambulatory Blood Pressure
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The objective of the study was to investigate whether home blood pressure (HBP) is a reliable alternative to ambulatory blood pressure (ABP) for the detection of the white coat effect (WCE). Hypertensive patients were randomized to measure HBP for 2 weeks or ABP for 24 h. The alternative measurement was then performed. Clinic blood pressure (CBP) was measured in the beginning and end of the study. Subjects with a difference of > or = 20 mm Hg systolic or > or = 10 mm Hg diastolic BP between CBP and awake ABP or CBP and HBP, were classified as clinic reactors. A total of 189 patients completed the study (79 on stable antihypertensive treatment). There was no difference in the magnitude of WCE assessed using the ABP or the HBP method (mean discrepancy, systolic BP: -1.5 +/- 11.7 mm Hg, 95% CI -3.2, 0.2; diastolic BP: 0.9 +/- 7.0, 95% CI -0.1, 1.9). A strong association existed between WCE calculated using the HBP or the ABP method (r = 0.64/0.59 systolic/diastolic, P < .001). The proportion of patients classified as clinic reactors was identical using the HBP or the ABP method (25.9%). Agreement between methods in the classification of clinic reactors was found in 147 patients (78%). The sensitivity and specificity of the HBP method to classify correctly clinic reactors (ABP method used as the standard) were 57% and 85%, respectively, whereas its positive and negative predictive value were 57% and 85%. These results indicate that HBP is not appropriate as an alternative to ABP diagnostic testing in the detection of WCE. Nevertheless, HBP appears useful as a screening test for the detection of this phenomenon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationEuropean Society of Hypertension Practice Guidelines for home blood pressure monitoring
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.54 · Cited by 482
Self-citationAgarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02324-x · Cited by 268
Self-citation
Metadata
- Authors
- Stergiou, G. S., Zourbaki, A. S., Skeva, I. I., & Mountokalakis, T. D.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-07-01
- Volume
- 11
- Issue
- 7
- Pages
- 820-827
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W1998446428
- Cited by
- 132
- References
- 1
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: White Coat Effect Detected Using Self-Monitoring of Blood Pressure at Home: Comparison With Ambulatory Blood Pressure. https://app.cochat.ai/papers/10.1016/s0895-7061(98)00038-7
- The paper
- Stergiou, G. S., Zourbaki, A. S., Skeva, I. I., & Mountokalakis, T. D. (1998). White Coat Effect Detected Using Self-Monitoring of Blood Pressure at Home: Comparison With Ambulatory Blood Pressure. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(98)00038-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.