Comparison of three blood pressure measurement methods for the evaluation of two antihypertensive drugs: feasibility, agreement, and reproducibility of blood pressure response
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Our objective was to compare three different methods of blood pressure measurement through the results of a controlled study aimed at comparing the antihypertensive effects of trandolapril and losartan. Two hundred and twenty-nine hypertensive patients were randomized in a double-blind parallel group study. After a 3-week placebo period, they received either 2 mg trandolapril or 50 mg losartan once daily for 6 weeks. At the end of both placebo and active treatment periods, three methods of blood pressure measurement were used: a) office blood pressure (three consecutive measurements); b) home self blood pressure measurements (SBPM), consisting of three consecutive measurements performed at home in the morning and in the evening for 7 consecutive days; and c) ambulatory blood pressure measurements (ABPM), 24-h BP recordings with three measurements per hour. Of the 229 patients, 199 (87%) performed at least 12 valid SBPM measurements during both placebo and treatment periods, whereas only 160 (70%) performed good quality 24-h ABPM recordings during both periods (P < .0001). One hundred-forty patients performed the three methods of measurement well. At baseline and with treatment, agreement between office measurements and ABPM or SBPM was weak. Conversely, there was a good agreement between ABPM and SBPM. The mean difference (SBP/DBP) between ABPM and SBPM was 4.6 +/- 10.4/3.5 +/- 7.1 at baseline and 3.5 +/- 10.0/4.0 +/- 7.0 at the end of the treatment period. The correlation between SBPM and ABPM expressed by the r coefficient and the P values were the following: at baseline 0.79/0.70 (< 0.001/< .0001), with active treatment 0.74/0.69 (0.0001/.0001). Hourly and 24-h reproducibility of blood pressure response was quantified by the standard deviation of BP response. Compared with office blood pressure, both global and hourly SBPM responses exhibited a lower standard deviation. Hourly reproducibility of SBPM response (10.8 mm Hg/6.9 mm Hg) was lower than hourly reproducibility of ABPM response (15.6 mm Hg/11.9 mm Hg). In conclusion, SBPM was easier to perform than ABPM. There was a good agreement between these two methods whereas concordance between SBPM or ABPM and office measurements was weak. As hourly reproducibility of SBPM response is better than reproducibility of both hourly ABPM and office BP response, SBPM seems to be the most appropriate method for evaluating residual antihypertensive effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Reference Values for Self-recorded Blood Pressure: A Meta-analysis of Summary Data
Thijs, L., Staessen, J. A., Celis, H., de Gaudemaris, R., Imai, Y., Julius, S., & Fagard, R. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.5.481 · Cited by 143
Home Self Blood Pressure Measurement in General Practice The SMART Study
Chatellier, G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00018-0 · Cited by 116
Cited by
Niiranen, T. J., Hänninen, M.-R., Johansson, J., Reunanen, A., & Jula, A. M. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.149336 · Cited by 390
Mancia, G., & Parati, G. (2004) · Journal of Hypertension · doi:10.1097/00004872-200403000-00001 · Cited by 219
Home Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
as members of the Japanese Society of Hypertension Committee for Guidelines for Self-monitoring of Blood Pressure at Home, Imai, Y., Kario, K., Shimada, K., Kawano, Y., Hasebe, N., Matsuura, H., Tsuchihashi, T., Ohkubo, T., Kuwajima, I., et al. (2012) · Hypertension Research · doi:10.1038/hr.2012.56 · Cited by 203
Niiranen, T. J., Asayama, K., Thijs, L., Johansson, J. K., Ohkubo, T., Kikuya, M., Boggia, J., Hozawa, A., Sandoya, E., Stergiou, G. S., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00100 · Cited by 120
“27 Self-measurement of blood pressure (BP) at home offers specific advantages over conventional clinic measurement because it allows identifying patients with white-coat, masked, and sustained hypertension with readings taken under standardized home conditions, little measurement variability, and good reproducibility.…”
Background
Metadata
- Authors
- Ragot, S., Genes, N., Vaur, L., & Herpin, D.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-06-01
- Volume
- 13
- Issue
- 6
- Pages
- 632-639
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2007636321
- Cited by
- 58
- References
- 3
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of three blood pressure measurement methods for the evaluation of two antihypertensive drugs: feasibility, agreement, and reproducibility of blood pressure response. https://app.cochat.ai/papers/10.1016/s0895-7061(99)00258-7
- The paper
- Ragot, S., Genes, N., Vaur, L., & Herpin, D. (2000). Comparison of three blood pressure measurement methods for the evaluation of two antihypertensive drugs: feasibility, agreement, and reproducibility of blood pressure response. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(99)00258-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.