Cited by 116Blood Pressure and Hypertension StudiesCardiovascular Health and Disease PreventionNon-Invasive Vital Sign Monitoring

Home Self Blood Pressure Measurement in General Practice The SMART Study

Chatellier, G·1996·American Journal of Hypertension

Abstract

The SMART study (Self-Measurement for the Assessment of the Response to Trandolapril) was performed in general practice and enrolled 1710 patients in order to assess on a large scale the feasibility and informative value of self-measurement of blood pressure at home (SMBP), define home blood pressure (BP) levels in comparison to office readings, and determine the number of home measurements necessary to provide an accurate and precise BP value. After a 2-week washout period, patients with office diastolic blood pressure within the range 95 to 119 mm Hg received 2 mg trandolapril once daily in the morning for 4 weeks. Four days of SMBP were performed both at the end of the washout period and the end of the treatment period, with an automatic printer-equipped oscillometric device (A&D UA751). The first day values were not analyzed. Thus, the maximum number of BP measurements obtained per patient and per period was 18. Four hundred and twenty-four patients (25%) did not perform any measurements. One thousand one hundred and nine patients (65%) performed at least 4 measurements. Among them, 619 (36%) correctly performed all 18 measurements. A preference for digits 0 and 5 was detected in physicians' measurements (three consecutive values, during a single office visit). This digit preference was not found with the semiautomatic device. When the number of measurements selected for analysis was increased from 1 to 18, in the 604 patients who provided all recordings and fullfilled all protocol criteria, the standard deviation of the mean BP of the cohort was reduced by 17% for SBP and by 23% for DBP. Eighty-five percent of this reduction was already achieved by six home measurements taken at random. BP was significantly lower at home than at the office by 13 +/- 15 mm Hg for systolic BP (SBP), and 8 +/- 10 mm Hg for diastolic BP (DBP). This difference was independent of age, more marked in women (P < .001 for SBP and P < .05 for DBP), and had a Gaussian distribution. Under treatment, office SBP/DBP decreased from 166.4 +/- 14.8/101.4 +/- 5.7 mm Hg to 144.7 +/- 14.2/86.1 +/- 8.3 mm Hg, while SMBP decreased from 153.2 +/- 17.8/93.8 +/- 10.1 mm Hg to 139.4 +/- 16.4/85.1 +/- 9.5 mm Hg (all P < .0001). A major aim in research studies and individual care is to reduce BP measurements variability. This study demonstrates the ability to evaluate baseline SMBP level in two-thirds of patients previously unfamiliar with the method, the ability to evaluate treatment effect in about one-half of the patients, the improvement in the measurement precision obtained with the repetition of measures (at least six home measurements), and the absence of bias of SMBP as compared to office measurements.

Integrity signals

Registry

Crossref · 10.1016/0895-7061(96)00018-0

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Chatellier, G.
Venue
American Journal of Hypertension
Published
1996-07
Volume
9
Issue
7
Pages
644-652
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2050370075
Cited by
116
References
24
Citations by year
2024: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 3 · 2013: 1 · 2012: 1
FWCI
2.08
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
home blood pressure monitoring, self-measurement, trandolapril, antihypertensive treatment response, office blood pressure, measurement variability, digit preference, oscillometric blood pressure monitoring, SMART study, hypertension, general practice, feasibility, ambulatory blood pressure monitoring
MeSH terms
Adolescent, Adult, Aged, Aged, 80 and over, Angiotensin-Converting Enzyme Inhibitors, Blood Pressure Determination, Family Practice, Female, Fingers, Humans, Indoles, Male, Middle Aged, Patient Compliance, Regional Blood Flow

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review