Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1986) · Springer eBooks · doi:10.1007/978-3-642-71010-0 · Cited by 2,123
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. R., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,071
Cosnier, S. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00024-x · Cited by 768
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Helsen, J. A., & Breme, H. (1998) · Wiley eBooks · Cited by 390
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Self-citationMicrofabrication Techniques for Integrated Sensors and Microsystems
Wise, K. D., & Najafi, K. (1991) · Science · doi:10.1126/science.1962192 · Cited by 309
Chronic neural stimulation with thin-film, iridium oxide electrodes
Weiland, J. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846685 · Cited by 262
Self-citationSilk, T., Hong, Q., Tamm, J., & Compton, R. G. (1998) · Synthetic Metals · doi:10.1016/s0379-6779(98)80132-x · Cited by 84
Impedance spectroscopy of protein polymer modified silicon micromachined probes
Athreya, S. A., & Martin, D. C. (1999) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(98)00223-4 · Cited by 32
Self-citationDesign ranges for silicon multichannel neural probes
Hetke, J. F., Anderson, D. J., & Wise, K. D. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656946 · Cited by 7
Self-citation
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Conductive Polymers: Opportunities and Challenges in Biomedical Applications
Nezakati, T., Seifalian, A., Tan, A., & Seifalian, A. M. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00275 · Cited by 977
Organic mixed ionic–electronic conductors
Paulsen, B. D., Tybrandt, K., Stavrinidou, E., & Rivnay, J. (2020) · Nature Materials · doi:10.1038/s41563-019-0435-z · Cited by 906
Metadata
- Authors
- Cui, X., Hetke, J. F., Wiler, J. A., Anderson, D. J., & Martin, D. C.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2001-08
- Volume
- 93
- Issue
- 1
- Pages
- 8-18
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W1972666377
- Cited by
- 330
- References
- 11
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.