Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gravesen, P., Branebjerg, J., & Jensen, O. S. (1993) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/3/4/002 · Cited by 1,280
A piezoelectric micropump based on micromachining of silicon
van Lintel, H. T. G., van De Pol, F. C. M., & Bouwstra, S. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)87005-7 · Cited by 620
Shoji, S., & Esashi, M. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/001 · Cited by 495
Thin-film shape-memory alloy actuated micropumps
Benard, W. L., Kahn, H., Heuer, A. H., & Huff, M. A. (1998) · Journal of Microelectromechanical Systems · doi:10.1109/84.679390 · Cited by 416
A novel micropump design with thick-film piezoelectric actuation
Koch, M., Harris, N. R., Maas, R., Evans, A. G. R., White, N. M., & Brunnschweiler, A. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/1/008 · Cited by 132
A high-performance silicon micropump for an implantable drug delivery system
Maillefer, D., van Lintel, H., Rey-Mermet, G., & Hirschi, R. (1999) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1999.746886 · Cited by 112
Cited by
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Current micropump technologies and their biomedical applications
Amirouche, F., Zhou, Y., & Johnson, T. (2009) · Microsystem Technologies · doi:10.1007/s00542-009-0804-7 · Cited by 332
Application of Micro- and Nano-Electromechanical Devices to Drug Delivery
Staples, M., Daniel, K., Cima, M. J., & Langer, R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9906-4 · Cited by 311
The significance of artificial intelligence in drug delivery system design
Hassanzadeh, P., Atyabi, F., & Dinarvand, R. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.05.001 · Cited by 305
Design and test of a high-performance piezoelectric micropump for drug delivery
Junwu, K., Zhigang, Y., Taijiang, P., Guangming, C., & Boda, W. (2005) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2004.12.002 · Cited by 217
Metadata
- Authors
- Cao, L., Mantell, S., & Polla, D.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2001-10
- Volume
- 94
- Issue
- 1-2
- Pages
- 117-125
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W1966100770
- Cited by
- 186
- References
- 6
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.