Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Abstract
This paper presents the development of a disposable plastic biochip incorporating smart passive microfluidics with embedded on-chip power sources and integrated biosensor array for applications in clinical diagnostics and point-of-care testing. The fully integrated disposable biochip is capable of precise volume control with smart microfluidic manipulation without costly on-chip microfluidic components. The biochip has a unique power source using on-chip pressurized air reservoirs, for microfluidic manipulation, avoiding the need for complex microfluidic pumps. In addition, the disposable plastic biochip has successfully been tested for the measurements of partial oxygen concentration, glucose, and lactate level in human blood using an integrated biosensor array. This paper presents details of the smart passive microfluidic system, the on-chip power source, and the biosensor array together with a detailed discussion of the plastic micromachining techniques used for chip fabrication. A handheld analyzer capable of multiparameter detection of clinically relevant parameters has also been developed to detect the signals from the cartridge type disposable biochip. The handheld analyzer developed in this work is currently the smallest analyzer capable of multiparameter detection for point-of-care testing.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ahn et al. developed a low-cost disposable plastic lab-on-a-chip device for biochemical detection of parameters such as blood gas concentration and glucose.
“Similarly, Ahn et al. [35] developed a low-cost disposable plastic lab-on-a-chip device for biochemical detection of parameters such as blood gas concentration and glucose.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [35]
The Ahn et al. biochip contains an integrated biosensor array for detecting multiple parameters and uses a passive microfluidic manipulation system instead of active microfluidic pumps.
“The biochip contains an integrated biosensor array for detecting multiple parameters and uses a passive microfluidic manipulation system instead of active microfluidic pumps.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [35]
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435 · see citing works
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D. K., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,298 · see citing works
Micromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,196 · see citing works
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,191 · see citing works
Lab-on-a-Chip: A Revolution in Biological and Medical Sciences.
Figeys, D., & Pinto, D. M. (2000) · Analytical Chemistry · doi:10.1021/ac002800y · Cited by 563 · see citing works
PDMS-based microfluidic devices for biomedical applications
Fujii, T. (2002) · Microelectronic Engineering · doi:10.1016/s0167-9317(02)00494-x · Cited by 525 · see citing works
Biosensors and biochips: advances in biological and medical diagnostics
Vo‐Dinh, T., & Cullum, B. M. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051549 · Cited by 509 · see citing works
Microfluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 505 · see citing works
Shoji, S., & Esashi, M. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/001 · Cited by 495 · see citing works
A passive pumping method for microfluidic devices
Walker, G. M., & Beebe, D. J. (2002) · Lab on a Chip · doi:10.1039/b204381e · Cited by 421 · see citing works
An AC magnetohydrodynamic micropump
Lemoff, A. V., & Lee, A. P. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00355-5 · Cited by 415 · see citing works
Fabrication and characterization of electroosmotic micropumps
Zeng, S., Chen, C.-H., Mikkelsen, J. C., & Santiago, J. G. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00855-3 · Cited by 402 · see citing works
Diffusion-based extraction in a microfabricated device
Brody, J. P., & Yager, P. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80219-1 · Cited by 275 · see citing works
Responsive biomimetic hydrogel valve for microfluidics
Yu, Q., Bauer, J. M., Moore, J. S., et al. (2001) · Applied Physics Letters · doi:10.1063/1.1367010 · Cited by 265 · see citing works
Chou, H.-P., Unger, M., & Quake, S. R. (2001) · Biomedical Microdevices · doi:10.1023/a:1012412916446 · Cited by 222 · see citing works
Microchips, microarrays, biochips and nanochips: personal laboratories for the 21st century
Kricka, L. J. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00451-x · Cited by 187 · see citing works
Cao, L., Mantell, S. C., & Polla, D. L. (2001) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00680-x · Cited by 186 · see citing works
Polyimide-based microfluidic devices
Metz, S. W., Holzer, R., & Renaud, P. (2001) · Lab on a Chip · doi:10.1039/b103896f · Cited by 186 · see citing works
Jeon, N. L., Chiu, D. T.-Y., Wargo, C. J., et al. (2002) · Biomedical Microdevices · doi:10.1023/a:1014683114796 · Cited by 144 · see citing works
Travelling wave-driven microfabricated electrohydrodynamic pumps for liquids
Fuhr, G., Schnelle, T., & Wagner, B. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/007 · Cited by 143 · see citing works
Microfabricated Biosensors and Microanalytical Systems for Blood Analysis
Lauks, I. R. (1998) · Accounts of Chemical Research · doi:10.1021/ar9700670 · Cited by 143 · see citing works
Micro mixer with fast diffusion
Miyake, R., Lammerink, T. S. J., Elwenspoek, M., et al. (2002) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.1993.296914 · Cited by 141 · see citing works
A novel micropump design with thick-film piezoelectric actuation
Koch, M., Harris, N. R., Maas, R., et al. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/1/008 · Cited by 116 · see citing works
A polymer-based microfluidic device for immunosensing biochips
Ko, J. S., Yoon, H. C., Yang, H., et al. (2003) · Lab on a Chip · doi:10.1039/b301794j · Cited by 113 · see citing works
Mélange passif dans les microcanaux : fabrication et expérience
Beebe, D. J. (2001) · Mécanique & Industries · doi:10.1016/s1296-2139(01)01114-9 · Cited by 110 · see citing works
Coming Soon: The Pocket DNA Sequencer
Service, R. F. (1998) · Science · doi:10.1126/science.282.5388.399 · Cited by 107 · see citing works
Polymer microchips bonded by O2-plasma activation
Wu, Z., Xanthopoulos, N., Reymond, F., et al. (2002) · Electrophoresis · doi:10.1002/1522-2683(200203)23:5 · Cited by 102 · see citing works
A water-powered osmotic microactuator
Su, Y.-C., Lin, L., & Pisano, A. P. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.805045 · Cited by 100 · see citing works
Micromachined interfaces: new approaches in cell immunoisolation and biomolecular separation
Desai, T. A., Hansford, D. J., & Ferrari, M. (2000) · Biomolecular Engineering · doi:10.1016/s1389-0344(00)00063-0 · Cited by 99 · see citing works
Fabrication of linear colloidal structures for microfluidic applications
Terray, A. V., Oakey, J. S., & Marr, D. W. M. (2002) · Applied Physics Letters · doi:10.1063/1.1503176 · Cited by 95 · see citing works
A planar microfabricated fluid filter
Brody, J. P., Osborn, T. D., Forster, F. K., & Yager, P. (1996) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80042-8 · Cited by 95 · see citing works
Lee, L. J., Madou, M. J., Koelling, K. W., et al. (2001) · Biomedical Microdevices · doi:10.1023/a:1012469017354 · Cited by 92 · see citing works
Microfabricated Drug Delivery Systems: Concepts to Improve Clinical Benefit
Martin, F. J., & Grove, C. (2001) · Biomedical Microdevices · doi:10.1023/a:1011442024658 · Cited by 78 · see citing works
Profile: Miniaturization and integration: challenges and breakthroughs in microfluidics
Ehrnström, R. (2002) · Lab on a Chip · doi:10.1039/b203480h · Cited by 68 · see citing works
Microfluidic devices for μ -TAS applications fabricated by polymer hot embossing
Becker, H., & Dietz, W. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.322081 · Cited by 64 · see citing works
FREEMANTLE, M. (1999) · Chemical & Engineering News · doi:10.1021/cen-v077n008.p027 · Cited by 55 · see citing works
Droplet-based nano/picoliter mixer using hydrophobic microcapillary vent
Hosokawa, K., Fujii, T., & Endo, I. (1999) · doi:10.1109/memsys.1999.746860 · Cited by 49 · see citing works
Development of Plastic Microfluidic Devices for Sample Preparation
Grodzinski, P. A., Liu, R. H., Chen, B., et al. (2001) · Biomedical Microdevices · doi:10.1023/a:1012400629650 · Cited by 47 · see citing works
Choi, J., Kim, S., Trichur, R. K., et al. (2001) · Springer eBooks · doi:10.1007/978-94-010-1015-3_181 · Cited by 45 · see citing works
Self-citationMicrofluidic flow control using selective hydrophobic patterning
Handique, K., Gogoi, B. P., Burke, D., et al. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.284515 · Cited by 43 · see citing works
A Rapid Vortex Micromixer for Studying High-Speed Chemical Reactions
Böhm, S., Greiner, K. B., Schlautmann, S., et al. (2001) · Springer eBooks · doi:10.1007/978-94-010-1015-3_9 · Cited by 40 · see citing works
Active valves and pumps for microfluidics
Schomburg, W. K., Fahrenberg, J., Maas, D., et al. (1993) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/3/4/012 · Cited by 40 · see citing works
Multi-analyte optical chemical sensor employing a plastic substrate
Malins, C., Niggemann, M., MacCraith, B. D., et al. (2000) · Measurement Science and Technology · doi:10.1088/0957-0233/11/8/302 · Cited by 39 · see citing works
A Novel In-Plane Passive Micromixer Using Coanda Effect
Hong, C.-C., Choi, J., & Ahn, C. H. (2001) · Springer eBooks · doi:10.1007/978-94-010-1015-3_11 · Cited by 38 · see citing works
Self-citationDifferential transport of DNA by a rectified Brownian motion device
Hammond, R. W., Bader, J. S., Henck, S. A., Deem, M. W., McDermott, G. A., Bustillo, J. M., & Rothberg, J. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1 · Cited by 37 · see citing works
Microarrays and microfluidic devices: miniaturized systems for biological analysis
Vinet, F., Chaton, P., & Fouillet, Y. (2002) · Microelectronic Engineering · doi:10.1016/s0167-9317(02)00458-6 · Cited by 36 · see citing works
Surface modification of micromachined silicon filters
Wang, Y., & Ferrari, M. (2000) · Journal of Materials Science · doi:10.1023/a:1004830408749 · Cited by 35 · see citing works
A Centrifugal Microfluidic Platform — A Comparison
Madou, M. J., Lu, Y., Lai, S., et al. (2000) · Springer eBooks · doi:10.1007/978-94-017-2264-3_133 · Cited by 35 · see citing works
A New Magnetically Actuated Microvalve for Liquid and Gas Control Applications
Sadler, D. J., Oh, K. W., Ahn, C. H., et al. (2000) · Cited by 33 · see citing works
Self-citationMcNeely, M. R., Spute, M. K., Tusneem, N. A., et al. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.359339 · Cited by 33 · see citing works
Fixed-volume metering microdispenser module
Puntambekar, A., Choi, J., Ahn, C. H., et al. (2002) · Lab on a Chip · doi:10.1039/b206934b · Cited by 31 · see citing works
Self-citationMulti-functional biochip for medical diagnostics and pathogen detection
Vo‐Dinh, T., Griffin, G. D., Stokes, D. L., et al. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00048-0 · Cited by 29 · see citing works
Sugita, K. (1997) · Progress in Organic Coatings · doi:10.1016/s0300-9440(97)00022-2 · Cited by 24 · see citing works
Development of Plastic Microneedles for Transdermal Interfacing Using Injection Molding Techniques
Trichur, R. K., Kim, S., Zhu, X., et al. (2002) · Springer eBooks · doi:10.1007/978-94-010-0295-0_132 · Cited by 23 · see citing works
A micromachined surface work-function gas sensor for low-pressure oxygen detection
Bergstrom, P. L., Patel, S. V., Schwank, J. W., et al. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)80336-x · Cited by 21 · see citing works
Analysis and experiment of centrifugal force for microfluidic ELISA CD platform
Ibrahim, F., Jahanshahi, P., Rahman, N. A., et al. (2010) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2010.5742282 · Cited by 21 · see citing works
Nagakura, T., Ishihara, K., Furukawa, T., et al. (1996) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(96)01954-5 · Cited by 20 · see citing works
A fully integrated biosensor array for measurement of metabolic parameters in human blood
Gao, C., Choi, J., Dutta, M., Chilukuru, S., Nevin, J. H., Lee, J. Y., Bissell, M. G., & Ahn, C. H. (2003) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2002.1002318 · Cited by 19 · see citing works
Self-citationStructurally Programmable Microfluidic Systems
Ahn, C. H., Puntambekar, A., Lee, S., et al. (2000) · Springer eBooks · doi:10.1007/978-94-017-2264-3_47 · Cited by 18 · see citing works
Self-citationDisposable air-bursting detonators as an alternative on-chip power source
Hong, C.-C., Choi, J., & Ahn, C. H. (2003) · doi:10.1109/memsys.2002.984247 · Cited by 16 · see citing works
Self-citation3.5 mu m thin valves in titanium membranes
Schomburg, W. K., & Scherrer, B. (1992) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/2/3/015 · Cited by 15 · see citing works
Microvalve with ultra-low leakage
Hirano, M., Yanagisawa, K., Kuwano, H., et al. (2002) · doi:10.1109/memsys.1997.581844 · Cited by 15 · see citing works
Effect of Surface Modification on Thermoplastic Fusion Bonding for 3-D Microfluidics
Puntambekar, A., Murugesan, S., Trichur, R. K., et al. (2002) · Springer eBooks · doi:10.1007/978-94-010-0295-0_142 · Cited by 12 · see citing works
Self-citationA New Fixed-Volume Metering Microdispenser Module based on sPROMs Technology
Puntambekar, A., Cho, H. J., Hong, C. C., et al. (2001) · Springer eBooks · doi:10.1007/978-3-642-59497-7_287 · Cited by 10 · see citing works
Self-citationWater-powered, osmotic microactuator
Su, Y.-C., Lin, L., & Pisano, A. P. (2002) · doi:10.1109/memsys.2001.906559 · Cited by 9 · see citing works
A Disposable on-Chip Air Detonator for Driving Fluids on Point-of-Care Systems
Hong, C.-C., Choi, J., & Ahn, C. H. (2002) · Springer eBooks · doi:10.1007/978-94-010-0504-3_115 · Cited by 6 · see citing works
Self-citationAn Air-Driven Fluidic Multiplexer Integrated with Microdispensers
Puntambekar, A., Choi, J., Ahn, C. H., et al. (2001) · Springer eBooks · doi:10.1007/978-94-010-1015-3_27 · Cited by 5 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396 · see citing works
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316 · see citing works
Ngoepe, M., Choonara, Y., Tyagi, C., Tomar, L., Du Toit, L., Kumar, P., Ndesendo, V., & Pillay, V. (2013) · Sensors · doi:10.3390/s130607680 · Cited by 92 · see citing works
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57 · see citing works
- Authors
- Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y.
- Affiliations
- University of Cincinnati (US)
- Louisiana State University (US)
- The University of Texas at Dallas (US)
- The Ohio State University (US)
- Venue
- Proceedings of the IEEE
- Published
- 2004-01
- Volume
- 92
- Issue
- 1
- Pages
- 154-173
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2146795298
- Cited by
- 504
- References
- 68
- Citations by year
- 2026: 2 · 2025: 10 · 2024: 10 · 2023: 10 · 2022: 11 · 2021: 13 · 2020: 13 · 2019: 13 · 2018: 19 · 2017: 22 · 2016: 28 · 2015: 37 · 2014: 29 · 2013: 37 · 2012: 30
- FWCI
- 27.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Proceedings of the IEEE (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- point-of-care testing, passive microfluidics, glucose measurement, lactate measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review