Cited by 504Microfluidic and Capillary Electrophoresis ApplicationsBiosensors and Analytical DetectionMicrofluidic and Bio-sensing Technologies

Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics

Ahn, C.H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., Lee, R.J.Y.·2004·Proceedings of the IEEE

Abstract

This paper presents the development of a disposable plastic biochip incorporating smart passive microfluidics with embedded on-chip power sources and integrated biosensor array for applications in clinical diagnostics and point-of-care testing. The fully integrated disposable biochip is capable of precise volume control with smart microfluidic manipulation without costly on-chip microfluidic components. The biochip has a unique power source using on-chip pressurized air reservoirs, for microfluidic manipulation, avoiding the need for complex microfluidic pumps. In addition, the disposable plastic biochip has successfully been tested for the measurements of partial oxygen concentration, glucose, and lactate level in human blood using an integrated biosensor array. This paper presents details of the smart passive microfluidic system, the on-chip power source, and the biosensor array together with a detailed discussion of the plastic micromachining techniques used for chip fabrication. A handheld analyzer capable of multiparameter detection of clinically relevant parameters has also been developed to detect the signals from the cartridge type disposable biochip. The handheld analyzer developed in this work is currently the smallest analyzer capable of multiparameter detection for point-of-care testing.

Integrity signals

Registry

Crossref · 10.1109/jproc.2003.820548

Cites

68 of 68 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Ahn et al. developed a low-cost disposable plastic lab-on-a-chip device for biochemical detection of parameters such as blood gas concentration and glucose.

    “Similarly, Ahn et al. [35] developed a low-cost disposable plastic lab-on-a-chip device for biochemical detection of parameters such as blood gas concentration and glucose.”
  • The Ahn et al. biochip contains an integrated biosensor array for detecting multiple parameters and uses a passive microfluidic manipulation system instead of active microfluidic pumps.

    “The biochip contains an integrated biosensor array for detecting multiple parameters and uses a passive microfluidic manipulation system instead of active microfluidic pumps.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y.
Affiliations
  • University of Cincinnati (US)
  • Louisiana State University (US)
  • The University of Texas at Dallas (US)
  • The Ohio State University (US)
Venue
Proceedings of the IEEE
Published
2004-01
Volume
92
Issue
1
Pages
154-173
ISSN
0018-9219 (ISSN-L)
OpenAlex
W2146795298
Cited by
504
References
68
Citations by year
2026: 2 · 2025: 10 · 2024: 10 · 2023: 10 · 2022: 11 · 2021: 13 · 2020: 13 · 2019: 13 · 2018: 19 · 2017: 22 · 2016: 28 · 2015: 37 · 2014: 29 · 2013: 37 · 2012: 30
FWCI
27.62
Type
journal article
Language
en
Open access
closed
Locations
Proceedings of the IEEE (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
point-of-care testing, passive microfluidics, glucose measurement, lactate measurement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review